CDVI 2EASY CDV-96KP Manual Download Page 8

EN

EN

8

CDV-96KP 

2EASY 2-wire Video Door Station with Keypad

6] PANVIEW & ZOOM

When a door station image is displayed, 

move to the desired position by touching

 

 

  on the screen to view the 

image in zoom mode.

Note:

 The edge of pantilt image will not be 

displayed.

You can zoom in or zoom out to identify anyone at the entrance.

Touch the      icon to zoom to the center position.

Pressing any button of the 

5-direction pad will enlarge 

the screen to full screen 

mode. 

Press     to return to the full 

screen mode 

Press  

        to navigate 

and see individuals up close.

Note:

 This function requires a monitor with fish-eye function to operate. (CDV-47 or 

CDV-47DX)

You can adjust the image display of a fish-eye door station when answering a call by 

using the 5-direction pad button.

7] SETTINGS

The table below explains the settings of each function.

•  Enter the master code to open the programming mode

•  Enter the corresponding setting code to perform the required function. 

•  Enter the value required using the setting codes below. 

•  Press “*”  to exit the setting mode.

Summary of Contents for 2EASY CDV-96KP

Page 1: ...WARRANTY YEAR 2 2EASY 2 wire Video Door Station with Keypad CDV 96KP EN ...

Page 2: ... Keypad 1 CONTENTS 2 Parts and Functions 3 3 Terminal Description 3 4 Installation 4 5 System Wiring and Connections 5 6 Panview Zoom 8 7 Settings 8 8 Unlock Operations 16 9 Product Specifcations 16 10 Cable Requirements 17 11 Precautions 17 Title Page ...

Page 3: ...aker 4 Touch keypad 5 Keypad LED 6 Call button 7 Microphone 8 Power LED 3 TERMINAL DESCRIPTIONS Lock Control Jumper To select the lock type Main Connect Port For connection of the bus line and the electronic locks L1 L2 Bus line connection no polarity PL External lock power input S1 GND Lock power connection port ...

Page 4: ...EN 4 CDV 96KP 2EASY 2 wire Video Door Station with Keypad 4 INSTALLATION Name label placement Use a screwdriver to remove the screw holding the panel in place Slide out the name label as shown ...

Page 5: ... be less than 250mA 3 The door lock control is not timed from Exit Button EB 4 The Unlock Mode monitor parameter must be set to 0 by default Door lock controlled with dry contact Notes 1 An external power supply must be used according to the lock power requirements 2 The internal relay contact is restricted to AC or DC Max 24V 1A 3 Remove jumper before connecting 4 Setup the monitor s Unlock Mode ...

Page 6: ...ront panel and hold for 2 seconds A QWERTY keyboard will display Refer to the following Note 1 The CDV 96KP must be connected before setting it up 2 Parameters will be saved in the CDV 96KP automatically It only needs to be set up on one monitor Multi door stations system wiring 4 max Camera 1 Device Address 0 Camera 2 Device Address 1 Camera 3 Device Address 2 Camera 4 Device Address 3 ...

Page 7: ...ad Multidoor monitors system wiring 4 max Simple IN OUT wiring CDV DBC4A system wiring IMPORTANT Subject to cable type Please see cable distance chart on pg 17 For further help call CDVI Technical Support on 44 0 1628 531300 or visit the CDVI Support Centre ...

Page 8: ... enlarge the screen to full screen mode Press to return to the full screen mode Press to navigate and see individuals up close Note This function requires a monitor with fish eye function to operate CDV 47 or CDV 47DX You can adjust the image display of a fish eye door station when answering a call by using the 5 direction pad button 7 SETTINGS The table below explains the settings of each functio...

Page 9: ...tting the unlock mode 0 NO 1 NC NO 04 6 Operation tone settings 0 on 1 off on 05 7 Reset code settings 1 2 3 4 06 8 function settings 0 Normal 1 Reverse Normal 07 9 Language Valid keys 0 9 Enable 08 10 Voice Volume Valid keys 0 9 5 09 11 MIC Volume Adjust microphone Valid keys 0 9 7 10 12 SPK Volume Adjust Valid keys 0 9 4 11 13 Device Address Valid keys 0 3 0 12 14 Night Light Level Valid keys 0 ...

Page 10: ...nds Switches off in standby mode Touch any key to illuminate This activation only turns on the keypad The unlock time can be set by both monitor and door station the valid value is always the time last set either at the door station or monitor When the cancel key is pressed the indicator will show the standby color the buzzer beeps and the system will exit the out of programming mode When there is...

Page 11: ...he standby color the buzzer beeps and the system will exit the out of programming mode When there isn t any operation within 10s the indicator will show the standby color the buzzer beeps and the system will exit the programming mode When a setting input fails the color of key indicator will turn red and the buzzer will beep Enter the setting code 04 Colour of key indicator green Beep Beep Enter t...

Page 12: ...he standby color the buzzer beeps and the system will exit the programming mode When a setting input fails the color of key indicator will turn red and the buzzer will beep Enter the setting code 08 Colour of key indicator green Beep Beep Enter the setting code 09 Enter the setting code 10 Enter the setting code 11 Colour of key indicator green Beep Beep Colour of key indicator green Beep Beep Col...

Page 13: ...f programming mode When there isn t any operation within 10s the indicator will show the standby color the buzzer beeps and the system will exit the programming mode When a setting input fails the color of key indicator will turn red and the buzzer will beep Enter the setting code 12 Colour of key indicator green Beep Beep Enter the setting code 13 Colour of key indicator green Beep Beep Enter cod...

Page 14: ...er the setting code 18 Colour of key indicator green Beep Beep Enter the setting code 19 Enter the setting code 20 Enter the setting code 60 Colour of key indicator green Beep Beep Colour of key indicator green Beep Beep Colour of key indicator green Beep Beep Enter code req ex 1006 1 12 digits 1006 Colour of key indicator green blue white Beep Enter code req ex 2011 1 12 digits 2011 Enter code re...

Page 15: ... of programming mode When there isn t any operation within 10s the indicator will show the standby color the buzzer beeps and the system will exit the programming mode When a setting input fails the color of key indicator will turn red and the buzzer will beep Enter the setting code 100 Colour of key indicator green Beep Beep Enter the setting code 101 Enter the setting code 102 Enter the setting ...

Page 16: ...r lights up the buzzer sounds and the electric door lock is unlocked note that you should press button if button is set as the confirm button after entering the unlock code The time interval during which the buttons must be pressed is aproximately 10 seconds If the time interval exceeds approximately 10 seconds the input value will be cleared If you make a mistake when inputting the user code pres...

Page 17: ...ble 2x1mm2 70 30 20 Twisted cable 2x1 5mm2 70 50 30 11 PRECAUTIONS Please clean the unit with soft cotton cloth don t use any wet wipes cloth or chemical cleaning agent If necessary use a little pure water or diluted soapy water to clean the dust The unit is weather resistant However do not spray high pressure water directly onto the keypad Excessive moisture may cause problems with the unit You m...

Page 18: ... 82 www cdvichina cn CDVI IBÉRICA SPAIN PORTUGAL 34 0 935 390 966 www cdviberica com CDVI ITALIA 39 0 321 90 573 www cdvi it CDVI MAROC 212 0 5 22 48 09 40 www cdvi ma CDVI SWEDEN SWEDEN DENMARK NORWAY FINLAND 46 0 31 760 19 30 www cdvi se CDVI UK UNITED KINGDOM IRELAND 44 0 1628 531300 www cdvi co uk CDVI POLSKA 48 0 12 659 23 44 www cdvi com pl All the information contained within this document ...

Reviews: