10] CABLE REQUIREMENTS
The maximum distance of the wiring is limited in the 2EASY system. Using different
cables may also affect the maximum distance which the system can reach.
Two to four monitors from outputs A, B, C & D of DBC4A
When monitor quantity < 20
Cable Usage
A
B
C
Twisted cable 2x0.75mm
2
60
60
30
Twisted cable 2x1mm
2
80
80
40
When monitor quantity > 20
Cable Usage
A
B
C
Twisted cable 2x1mm
2
70
30
20
Twisted cable 2x1.5mm
2
70
50
30
11] PRECAUTIONS
• Please clean the unit with soft cotton cloth, don’t use any wet wipes cloth or chemical
cleaning agent. If necessary, use a little pure water or diluted soapy water to clean the
dust.
• The unit is weather resistant. However do not spray high pressure water directly onto
the keypad. Excessive moisture may cause problems with the unit.
• You must use the correct power adapter which is either supplied or approved by the
manufacturer
• Pay attention to the high voltage inside the products, please refer service only to a
trained and qualified professional.
Recommended cable:
16AWG, Belden 8471