EN
EN
13
CDV-96KP
2EASY 2-wire Video Door Station with Keypad
13. Device address
setting
(Default: 0)
14. Night light level
setting
(Default: 4)
Device address Settings:
0 (device address:0),
1 (device address:1),
2 (device address:2),
3 (device address:3).
• Night Light Level: 0~5.
• The higher the number,
the brighter the night
lights.
• When the “* cancel” key is pressed, the indicator will show the
standby color, the buzzer beeps, and the system will exit the out of
programming mode.
• When there isn’t any operation within 10s, the indicator will show
the standby color, the buzzer beeps, and the system will exit the
programming mode.
• When a setting input fails, the color of key indicator will turn red and
the buzzer will beep.
Enter the setting code
12+#
Colour of key indicator
(green)
--> Beep+, Beep
Enter the setting code
13+#
Colour of key indicator
(green)
--> Beep+, Beep
Enter code req.
(ex.: 1)
Range: 0-2
1+#
Colour of key indicator
(green --> blue-white)
--> Beep+
Enter code req.
(ex.: 3)
range: 0-5
3+#
Colour of key indicator
(green --> blue-white)
--> Beep+
Enter the master code
(Default: [
1 2 3 4
] + [#] )
The colour of key indicator (blue-white)
--> Beep+, Beep