CDR FOODLABFAT Operator'S Manual Download Page 7

   Operator’s manual 

 

 

October 2012

                                                                                                                                 

 

 

GRAPHIC SIGN

 (defined as a perceptible visual figure to transmit information 

independent from the language) 
 

With regards to this, in the successive paragraphs are explanations about the icons 
that are in use in this manual. 
 

Danger symbols 

 

WARNING 

 

ELECTRIC 

SHOCK 

 

TOXIC 

SUBSTANCES 

 

BIOLOGIC 
HAZARDS 

 

SCIN 

IRRITATION 

 

FLAMMABLE 

Prohibition symbols 

 

SMOKING 

FORBIDDEN 

 

ENTRANCE PERMITTED TO AUTHORIZED 
ONLY 

Generic symbols 

 

READ 

DIRECTIONS 

FOR USE 

 

GENERAL 

INFORMATION 

FOR THE USER 

 
 

1.3.2 Safety of the product 

1.3.2.1 European Directives consulted during the design stage 

The instrument has been designed and constructed following the health and safety 
requirements of the directive: 
 
Table 1: European Directives consulted during the design stage 

Directive 
Number

 

Title and implementation into Italian legislation

 

 
89/336/CEE 
and successive 
amendments

 

 

89/336/CEE: Council Directive of the 03/05/89 for the legislative 
alignment of the member states relative to electromagnetic 
compatibility 

 

Italian legislation implementation: 
D. Lgs. of the 4th December 1992, n. 476 "Activation of the 
Council Directive 89/336/CEE of the 3rd May 1989 about the 
legislative alignment of the member states relative to 

Summary of Contents for FOODLABFAT

Page 1: ...Operator s manual October 2012 1 Instrument for the Quality Control of Oils and Fats In Vitro Analysis Made in Italy CDR s r l Firenze Italy Development Manufacturing Sales Technical Service...

Page 2: ...arch 2011 J Schenne 2nd edition R3 October 2012 J Schenne 3th edition USA Document made by Ing Buero fuer Bio Prozessanalytik J Schenne Ohlstuecken 9 21033 Hamburg Germany info foodlab arcor de In cas...

Page 3: ...and 6 1 3 2 Safety of the product 7 2 System description 9 2 1 The FOODLABfat analyser 9 2 2 Instrument nameplate 9 2 3 Operating parts 10 2 4 1 Key folio layout and display 10 2 3 2 Reading cells 10...

Page 4: ...f the results 16 4 6 Standardisation of tests 17 4 7 Menu description 17 4 7 1 Edit dialogue 17 4 7 2 Setup dialogue 18 4 7 3 Auto start dialogue 19 4 7 4 Printer dialogue 19 4 7 5 Info dialogue 20 5...

Page 5: ...way and using the correct methods as agreed by the manufacturer If the operator finds a disagreement between anything described in this manual and the instrument he must advise the manufacturer immed...

Page 6: ...rixes different from those indicated in the methodologies The instrument is specifically calibrated during construction to test the biological matrixes indicated in the methodologies The instrument ca...

Page 7: ...2 Safety of the product 1 3 2 1 European Directives consulted during the design stage The instrument has been designed and constructed following the health and safety requirements of the directive Tab...

Page 8: ...requisites of the norms EN 50081 1 Electromagnetic compatibility emission residential environment light industry EN 55022 A Radio disturbance measures on equipment for computer technology EN 50082 2...

Page 9: ...Reading cells Figure 2 1 Modules 2 2 Instrument nameplate The instrument has a nameplate that displays the CE mark and identification data Figure 2 2 Nameplate Important Never remove the nameplate fr...

Page 10: ...Up Move the cursor upwards on the display stop number of samples Down Move the cursor downwards on the display interruption of a running test Power ON OFF the instrument Numerical keys 0 9 Enter Confi...

Page 11: ...ep it clean don t touch it with fingers Figure 2 5 CDR test cuvette 2 3 4 CDR Reagent kit Test kit contains 10 pre filled cuvettes in an aluminium bag For example Test name Acidity Code 300125 Lot rea...

Page 12: ...in its carton must be stored in a closed environment within the temperature range 20 C to 70 C 4 F to 158 F and a relative non condensed humidity of 20 to 90 The storage place must not be exposed to c...

Page 13: ...ed as follows A Take the FOODLABfat out of the carton and put it on a plane surface in such a position that it is not exposed by mechanical vibrations or extreme temperature fluctuations or excessive...

Page 14: ...peration procedure The FOODLABfat is an instrument equipped with dedicated software for the deter mination of parameters on different oils and fat extracts and alimentary matrixes of various natures T...

Page 15: ...the enter key to proceed the calibration process After that the results are shown on display All installed optics must be ok In case of differences refer to chapter 5 Error messages Press enter key t...

Page 16: ...ion the cursor with arrow key up down to select the test to run Press enter key to confirm the first test dialogue is shown on display It is also possible to run a test on a specific reading cell E g...

Page 17: ...position ANL STD to STD ANL then you will be requested to define up to 14 points After measuring results are shown on display together with K and Q values and the regression coefficient R These values...

Page 18: ...nal value SMP Timer definition of the incubation time up to 15 minutes for an activation prior reading of the sample To change this time press the enter key and successively the up arrow key and the d...

Page 19: ...7 3 Auto start dialogue In this mode it is possible to insert the time of automatic switching on of the FOODLABfat instrument if it is connected to the mains and is ready for testing after 45 minutes...

Page 20: ...4 7 5 Info dialogue After selection the following information is shown Registration represents the registration of the instrument Firmware represents the version of programme installed Operator operat...

Page 21: ...own and then switch it on again If the problem persist please contact the technical assistance department for repairing In the following are summarized the instructions to be followed in case specific...

Page 22: ...2 Rif key has been selected 6 Maintenance 6 1 Recommended actions and precautions The FOODLABfat instrument is easy to use and it is normally maintenance free Do not spill any liquid over the instrum...

Page 23: ...your distributor 7 2 Spare parts CDR AEP 119 1 x roll of thermal printer paper 57 mm diam 45 mm CDR ALP 004 external power adapter 100 230V AC to 12V dc CDR 225 058 protective cover for reading cells...

Page 24: ...Operator s manual October 2012 24 7 3 Declaration of conformity...

Page 25: ...d 4 x 3 positions Cuvettes Volume at triangular mark 1000 l mixed polymer for optical use Cups Polystyrol made Sample volume depending on test Throughput depending on test Processor MC 68331 micro pro...

Page 26: ...READ_CHECK chk cc check reading cells cc OK KO DATE date in the days month years format TIME time in the hours minutes format CALIBRATION calibration DATE date in the days months years format TIME tim...

Page 27: ...he rear enable to connect the analyser to a computer FOODLABfat can be connected to LIMS Laboratory Information Management System and the XML Extensible Markup Language protocol 7 6 Waste disposal The...

Page 28: ...tes of particular interest protected by the norms in force ATTENTION Do not hesitate to contact your distributor about any question that is inherent to the demolition procedures of the instrument and...

Page 29: ...Operator s manual October 2012 29...

Reviews: