9
Display
Adjustment
Function
bL on
Back light ON
Good contrast display which
can also be read in darkness
bL oFF
Back light OFF
Battery saving
bL Ch
Back light will be switched off
automatically if no weight
change for 10 seconds.
Battery saving
Press the
SET/TARE
key to confirm setting.
11. Data Hold
The scale has the display reading hold function so that important reading can be captured for a period.
Press the
HOLD/PRINT
key once during weighing, display reading can be frozen. Press the
HOLD/PRINT
key again to change back to normal weighing mode.
12. Auto Zero Tracking Function
The auto zero tracking function is used to tare out small variations in weight automatically. In some
applications, small quantities are removed or added to the material to be weighed, this feature can
affect the weighing results due to the “stability compensation” function in the scale.
(Example: Slowly draining fluids from a container on the scale). When application involves small
variations of weight, it is advisable to switch off this function. However, the weight reading will look less
stable.
In weighing mode, press and hold the
FUNCTION
key until "UNIT" appears on the display.
Press the
UNIT/COUNT or HOLD/PRINT
key several times until "tr" is displayed.
Press
SET/TARE
key to display current setting.
Press the
UNIT/COUNT
or
HOLD/PRINT
key to select setting based on below table.
tr
on
Function activated
tr
oFF
Function deactivated
Press the
SET/TARE
key to confirm selection. The scale returns to weighing mode.
13. Reset to Factory Settings
This function resets all scale settings to factory setting.
In weighing mode, press and hold the
FUNCTION
key until "Unit" appears.
Press the
UNIT/COUNT
key or
HOLD/PRINT
key several times until "rSt" is displayed.
Press the
SET/TARE
key to display current setting.
Select the desired settings by pressing the
UNIT/COUNT
key or
HOLD/PRINT
key.
rSt
yES
Scale will be reset to factory setting
rSt
no
Scale keeps its individual setting
Press the
SET/TARE
key to confirm selection. The scale returns to weighing mode.