CDN SD2204 Instruction Manual Download Page 9

 

Display   

Adjustment   

Function   

  bL on

 

Back light ON 

Good contrast display which 
can also be read in darkness

 

  bL oFF

 

Back light OFF 

Battery saving 

 

  bL Ch

 

Back light will be switched off 
automatically if no weight 
change for 10 seconds.   

Battery saving   

Press the

 SET/TARE

 key to confirm setting.

 

 
 

11. Data Hold 

 

The scale has the display reading hold function so that important reading can be captured for a period. 
Press the 

HOLD/PRINT

 key once during weighing, display reading can be frozen. Press the 

HOLD/PRINT

 key again to change back to normal weighing mode.

 

 
 

12. Auto Zero Tracking Function 

 

The auto zero tracking function is used to tare out small variations in weight automatically. In some 
applications, small quantities are removed or added to the material to be weighed, this feature can 
affect the weighing results due to the “stability compensation” function in the scale.   
(Example: Slowly draining fluids from a container on the scale). When application involves small 
variations of weight, it is advisable to switch off this function. However, the weight reading will look less 
stable. 
In weighing mode, press and hold the

 FUNCTION

 key until "UNIT" appears on the display.   

Press the 

UNIT/COUNT or HOLD/PRINT 

key several times until "tr" is displayed. 

Press 

SET/TARE 

key to display current setting. 

Press the 

UNIT/COUNT

 or 

HOLD/PRINT

 key to select setting based on below table.

 

tr

 

 

on

    Function activated 

 

tr

 

 

oFF

    Function deactivated 

 

Press the 

SET/TARE

 key to confirm selection. The scale returns to weighing mode. 

 

 
 

13. Reset to Factory Settings 

 

This function resets all scale settings to factory setting.   
In weighing mode, press and hold the 

FUNCTION 

key until "Unit" appears.   

Press the

 UNIT/COUNT

 key or

 HOLD/PRINT

 key several times until "rSt" is displayed.   

Press the 

SET/TARE

 key to display current setting.   

Select the desired settings by pressing the 

UNIT/COUNT

 key or 

HOLD/PRINT

 key. 

 

rSt   

yES

  Scale will be reset to factory setting

 

rSt   

no 

  Scale keeps its individual setting

 

Press the 

SET/TARE

 key to confirm selection. The scale returns to weighing mode. 

 

 

Summary of Contents for SD2204

Page 1: ...1 PORTION CONTROL SCALE 22 pounds 352 ounces 10 kilograms by grams ounces troy ounces pounds Hong Kong tael Taiwan tael grains pennyweights mommes tolas carats and free factor units...

Page 2: ...amic weighing In the event that small quantities are removed or added to the material to be weighed incorrect weighing results can be displayed due to the stability compensation in the scale Example s...

Page 3: ...rox 2 hours at room temperature after it has been disconnected from the mains Avoid static charging of the material to be weighed Major display deviations incorrect weighing results are possible if el...

Page 4: ...enter of the platform Now press the SET TARE key Short time later CAL F appears then returns automatically to the normal weighing mode Readings of the adjustment weight appear in the display An error...

Page 5: ...ttings in the menu ZERO Zero scale 1 Weighing Mode Turn on the scale using the ON OFF key The scale will perform self test for few seconds When the zero display appears the scale is ready for operatio...

Page 6: ...unction can be used for unit weight control fabrication control etc Turn on scale using the ON OFF key and wait for the zero display Put the target weight on the platform and tare to zero by pressing...

Page 7: ...RE key Weigh component Press the SET TARE key Net total sum weight of components will be displayed If necessary repeat above procedures to complete the formula up to the desired final value Back to we...

Page 8: ...tor FFA xx xx In order to enter an own conversion factor press the UNIT COUNT key or HOLD PRINT key as explained above until FFA is displayed Press the SET TARE key to confirm the selection The last d...

Page 9: ...ner on the scale When application involves small variations of weight it is advisable to switch off this function However the weight reading will look less stable In weighing mode press and hold the F...

Page 10: ...RINT key several times until Pr is displayed Press SET TARE key to display current setting Press the UNIT COUNT or HOLD PRINT key to select setting based on below table Display Function Pr PC Data out...

Page 11: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 M S N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 B U1 U2 U3 CR LF d Format for error condition 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 B B B B B B B B B B B E r r o...

Page 12: ...and corrode the electronic circuits Do not subject the scale to excessive force shock dust temperature or humidity which may result in malfunction shorter electronic life span damaged battery and or d...

Page 13: ...pon receipt of the unit prepaid at CDN PO Box 10947 Portland OR 97296 0947 This warranty does not cover damage in shipment or failure caused by failure to adhere to the accompanying instructions inade...

Reviews: