CDN SD2204 Instruction Manual Download Page 3

 

Before use

 

 

Please read all instructions to familiarize yourself with the specification and operations before using and 
programming the scales. 
 

Installation

 

The scales are designed in a way that reliable weighing results are achieved with consistent usage 
conditions. Selecting the right location for the scale is important.   
 

Therefore, observe the following for the installation: 

 

 Place the scale on a firm, level surface; 

 

 

 Avoid extreme heat and temperature fluctuation such as installation in the direct sunlight; 

 

 

 Protect the scale against direct draughts due to open windows and doors; 

 

 

 Avoid vibration during weighing; 

 

 

 Protect the scale against high humidity, moisture and dust; 

 

 

 Do not expose the device to extreme humidity for longer periods of time. Non-permitted condensation 

(condensation of air humidity on the appliance) may occur if a cold appliance is taken to a 
considerably warmer environment. In this case, acclimatize the disconnected appliance for approx. 
2 hours at room temperature after it has been disconnected from the mains.   

 

 Avoid static charging of the material to be weighed. 

 

 

 Major display deviations (incorrect weighing results) are possible if electromagnetic fields occur as 

well as due to static charging and instable power supply. It is then necessary to change the location.   
 

 In order to obtain exact results with the electronic scales, your scale must have reached the operating 

temperature. During this warming up time the scale must be connected to the power supply 
(mains, battery, rechargeable battery).   

 
 

Battery Installation

 

Using a flat screwdriver, remove the battery cover on the bottom of the scale. Connect the 9V alkaline 
battery, observing polarity, and then replace the battery door. Tighten screw to secure.

 

 
 

Using Adapter

 

 

  Before using the external mains adapter, make sure that the printed voltage must comply with 

the local voltage. 

 

Only use original CDN mains adapter. The use of other adapter is subject to approval by CDN.

 

 

 

Connecting Peripheral Devices 

 

Before connecting or disconnecting of additional devices (printer, PC) to the data interface, always 
disconnect the scale from the power supply.   

Summary of Contents for SD2204

Page 1: ...1 PORTION CONTROL SCALE 22 pounds 352 ounces 10 kilograms by grams ounces troy ounces pounds Hong Kong tael Taiwan tael grains pennyweights mommes tolas carats and free factor units...

Page 2: ...amic weighing In the event that small quantities are removed or added to the material to be weighed incorrect weighing results can be displayed due to the stability compensation in the scale Example s...

Page 3: ...rox 2 hours at room temperature after it has been disconnected from the mains Avoid static charging of the material to be weighed Major display deviations incorrect weighing results are possible if el...

Page 4: ...enter of the platform Now press the SET TARE key Short time later CAL F appears then returns automatically to the normal weighing mode Readings of the adjustment weight appear in the display An error...

Page 5: ...ttings in the menu ZERO Zero scale 1 Weighing Mode Turn on the scale using the ON OFF key The scale will perform self test for few seconds When the zero display appears the scale is ready for operatio...

Page 6: ...unction can be used for unit weight control fabrication control etc Turn on scale using the ON OFF key and wait for the zero display Put the target weight on the platform and tare to zero by pressing...

Page 7: ...RE key Weigh component Press the SET TARE key Net total sum weight of components will be displayed If necessary repeat above procedures to complete the formula up to the desired final value Back to we...

Page 8: ...tor FFA xx xx In order to enter an own conversion factor press the UNIT COUNT key or HOLD PRINT key as explained above until FFA is displayed Press the SET TARE key to confirm the selection The last d...

Page 9: ...ner on the scale When application involves small variations of weight it is advisable to switch off this function However the weight reading will look less stable In weighing mode press and hold the F...

Page 10: ...RINT key several times until Pr is displayed Press SET TARE key to display current setting Press the UNIT COUNT or HOLD PRINT key to select setting based on below table Display Function Pr PC Data out...

Page 11: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 M S N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 B U1 U2 U3 CR LF d Format for error condition 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 B B B B B B B B B B B E r r o...

Page 12: ...and corrode the electronic circuits Do not subject the scale to excessive force shock dust temperature or humidity which may result in malfunction shorter electronic life span damaged battery and or d...

Page 13: ...pon receipt of the unit prepaid at CDN PO Box 10947 Portland OR 97296 0947 This warranty does not cover damage in shipment or failure caused by failure to adhere to the accompanying instructions inade...

Reviews: