39
Table for the choice of the injectors
GB
Cat:
II
2H3+
I
NCREASE OF AIR NECESSARY FOR GAS COMBUSTION
(2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Auxiliary (A)
2,00
Semi-rapid (SR)
3,50
Rapid (R)
6,00
Triple-ring
7,00
Oven (left)
7,40
Grill (left)
5,00
Oven (right)
4,40
Grill (right)
4,00
Auxiliary (A)
1,00
0,30
27
50
-
72 (X)
-
Semi-rapid (SR)
1,75
0,45
32
65
-
97 (Z)
-
Rapid (R)
3,00
0,75
42
85
-
115 (Y)
-
Triple-ring
3,50
1,50
65
95
-
135 (T)
-
Oven (left)
3,70
0,75
40
92
fully open
140
5
Grill (left)
2,50
-
-
80
fully open
-
120
4
Oven (right)
2,20
0,63
38
72
fully open
110
4
Grill (right)
2,00
-
-
70
fully open
-
105
2
Nominal
Power
[kW]
Reduced
Power
[kW]
Ø injector
[1/100 mm]
G 30
- 28-30 mbar
G 31
- 37 mbar
G 20
20 mbar
BURNERS
By-pass
[1/100 mm]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
Tube ring
opening
[mm]
Tube ring
opening
[mm]
adjustable
adjustable