OPM-C60/OPP-C60
System Manual
PA72P002_en
Edition: 40
Page 16 - 68
Product specific instructions
Confidential
© CCV GmbH - It is not allowed to duplicate or distribute this document without our agreement.
b) Wire List
P1
Color
PIN OUT DETAILS P2
1
White
V_IN-OUT
1
2
Black
GND
2
3
Red
<= RS232
3
4
Green
=> RS232
4
7
Blue
Wake UP
7
8
Blue
GND_IN-OUT
8
Note: All cables have to pass electrical test.
5.7.9.1 General information about the COR
The COR provides the following IP protection classes.
-
COR-A10, -A12, -A20
o
front panel IP65
o
back panel IP20
-
COR-B20
o
back panel IP20
o
front panel IP32
▪
3 = foreign object size > 2.5mm diameter cannot entry
▪
2 = water drops with 15° angle have no effects of damage
Further information for COR-B20
Water can entry to the backside of the COR reader (inside the vending machine) over the card
slot. The contacting unit of the COR is opened at the bottom side to let foreign objects fall out
or to let invaded water flow out (this is needed to prevent a blockade of the contacting unit).
There should be mounted a drain sheet inside the vending machine under the COR-B20 to
shield the electronics under the COR-B20.
The openings at the backside of the COR housing for connector plugs or flexible connectors
are mounted above the contacting unit. So there is no possibility for water drops to entry in this
area to the COR electronics over the card slot.
Only spray water or hose water could entry over some corners. Depending on the location
where the COR is used we recommend to provide a protection board to prevent the device
from soiling or spray water.