OPM-C60/OPP-C60
System Manual
PA72P002_en
Edition: 40
Page 12 - 68
Product specific instructions
Confidential
© CCV GmbH - It is not allowed to duplicate or distribute this document without our agreement.
5.7.7 OPP / OPM Status LED
There are two status LEDs at the rear side
of the OPP / OPM, “PWR” (Power) and “STA”
(Status), which has the following meanings.
Status
PWR
heating off
(green, PWR)
PWR
heating on
(orange, PWR)
STA (rot, controllable)
Boot process
permanently on permanently on permanently on
Terminal ready, waiting for
login
permanently on permanently on
2x slowly blinking, 2x fast
blinking
Terminal
ready,
login
successful
permanently on permanently on off
SecureLink/4eye to reader
not active
permanently on permanently on 1x slowly, 1x fast
Startup lock
permanently on permanently on 1x slowly, 2x fast
Initialization
lock
/
Diagnosis lock
permanently on permanently on 1x slowly, 3x fast
Fraud
permanently on permanently on fast blinking
Not identified / other error permanently on permanently on slowly blinking