background image

- 1 -

LDLB/LDLB-IP Series

Bar Lights

Instruction Guide

Thank you for purchasing a CCS product. To ensure proper use of 

the product, please read this instruction guide before use and keep 

it for your future reference.

These LED Light Units feature integrated light control and ON/OFF control circuits.

The LEDs are driven with a constant-current system and the light is set to any of 100 levels with variable-current control.

You can change between Constant Lighting Mode and Overdrive Mode.

You can manually set the light intensity from the operating panel or set it with an analog input (0 to 10 V) from an external device.

You can daisy-chain up to three Light Units to provide power and externally control the light intensity of all of the Light Units together.

The LDLB-IP Series provides IP67 water resistance.

Features

  The following symbols indicate and classify the precautions in the 

    Instruction Guide.

PROHIBITED

DISASSEMBLY

PROHIBITED

DO NOT TOUCH

WITH WET HANDS

DO NOT SUBJECT 

TO MOISTURE

MANDATORY

ACTIONS

These symbols indicate

prohibited actions.

This symbol indicates 

required actions.

This product has been designed with full consideration of safety. However, incorrect usage of the product may result in 

fire, electric shock, or other serious accidents. Observe the following precautions.

Warning

Indicates that incorrect 

usage may result in 

serious injury or death.

Caution

Indicates that incorrect 

usage may result in injury 

or property damage.

  The following symbols are used in this Instruction Guide to indicate 

   and classify the relative importance of warnings and cautions.

Caution

Do not drop the product 

or subject it to impact. 

Doing so may cause the 

product to malfunction.

PROHIBITED

Do not bundle product 

cables with highvoltage 

lines or power lines. 

Doing so may cause the 

product to malfunction. 

Allow leeway between 

t h e   c a b l e s   w h e n 

installing them.

MANDATORY

ACTIONS

Be c aref ul of st atic 

elec tr ic it y. Damage 

to the LED light may 

o c c u r,   i f   a   p e r s o n 

c h a r g e d  w it h  st at i c 

electricity touches it. 

Keep the product away 

from all items charged 

with static electricity.

PROHIBITED

B e f o r e   m o v i n g   t h e 

product, disconnect 

all connecting cables. 

Damaging the cables 

may result in fire or 

electric shock.

MANDATORY

ACTIONS

Do not bend a cable 

past its natural bending 

radius or jam a cable 

into a narrow space 

w h e n   w i r i n g   t h e 

product. Doing so may 

cause product failure.

PROHIBITED

Always hold onto the 

plug or connector when 

d i s c o n n e c t i n g   t h e 

cables. Pulling on the 

cable may damage the 

cable and result in fire 

or electric shock.

MANDATORY

ACTIONS

Do not intentionally 

s h o r t - c i r c u i t   t h e 

positive and negative 

output terminals.

PROHIBITED

If there is dust or other 

foreign matter on the 

electrodes, turn OFF 

the power supply and 

then use a dr y cloth 

to remove the dust or 

foreign matter. Failure to 

do so may result in fire.

MANDATORY

ACTIONS

B e s u r e t o u s e t h e 

p r o d u c t   w i t h i n   t h e 

range of input voltage. 

Applying the voltage 

beyond the range may 

cause product failure.

PROHIBITED

Do not wipe the product 

with organic solvent s, 

such as paint thinner or

benzene. Discoloration 

or deterioration of the 

product surfaces may 

occur.

PROHIBITED

1

2

3

4

5

6

Important Information for Equipment Safety

Confirming Product Information

Names and Functions of Parts

Connections

Setting the Light Intensity on the Operating Panel

External Control of the Light Intensity

- Read Before Use -

Warning

Do not disassemble 

or modify the product. 

Doing so may result in 

fire or electric shock.

DISASSEMBLY

PROHIBITED

LED light radiation may 

cause corneal or retinal 

abnormalities if you 

look directly at the light. 

To prevent harmful light 

exposure, never look 

directly at the LED light.

MANDATORY

ACTIONS

D o n o t c o n n e c t o r 

disconnect the Light 

Unit and cables with 

wet hands. Doing so 

may result in electric 

shock.

DO NOT TOUCH

WITH WET HANDS

This product generates 

high temperatures. Do 

not touch the product 

while it is turned on or 

immediately after it is 

turned off, or burning 

m ay r e s u l t . P r ov i d e 

cooling with a fan or 

other ventilation if the 

product is to be used in 

a closed space.

MANDATORY

ACTIONS

Using LDLB- series 

Light Units (not water 

resistant)

M a k e   s u r e   t h a t   t h e 

product is free of moisture 

or any liquid. Exposure to 

water may result in fire, 

electric shock.

DO NOT SUBJECT 

TO MOISTURE

Connect or disconnect 

the light cable only after 

turning off the power 

supply. Failure to do 

so may result in circuit 

damage, f ire caused 

by a minute spark, or 

electric shock.

MANDATORY

ACTIONS

If abnormal condition occurs such as fuming, heat, smell, 

noise, or so on, stop using the product immediately, and 

turn off the power supply. A fire or electric shock may 

result if the product is kept used.

MANDATORY

ACTIONS

The following label is attached to the LED light. The color of the label indicates the luminescence color of the product. The name 

label specifies the model name, power consumption, and serial number. Be sure to check the contents before using the product 

and handle the label with care. If the label is missing or damaged and the contents cannot be checked, please contact CCS Inc.

Connecting One Light Unit

Daisy-chaining Two or Three Light Units

Maximum Cable Length

Before you connect the Input Cable or Link Cable, make sure that the power supply is turned OFF. Making connec-

tions with the power supply turned ON may result in fire, electric shock, or breakdown in the Light Unit.

Handle the Light Units and connectors with care. Do not deform or damage the connectors.

Connect the cables correctly to the Light Units.

Connect a Sealing Cap to any output connectors to which a cable is not connected to maintain water resistance. The 

Sealing Cap is connected to the output connector when the Light Unit is shipped.

If the Light Unit is not used for a long period of time with the cable disconnected, attach the Cap to the connector or take 

other measures to maintain water resistance.

Observe the following precautions to prevent electrical shock and accidents from water entry.

Using LDLB-IP-series Light Units

Warning

Caution

1

1

2

2

You can daisy-chain up to three Light Units to set the light intensities or turn ON and OFF all of the Light Units together.

The maximum length of the 24-VDC power supply cable depends on the wire diameter, operating mode, and number of con-

nected Light Units. The maximum cable lengths are given in the following table.

One Light Unit Connected: The table gives the maximum length of the Input Cable.

Two or Three Light Units Connected: The table gives the maximum total length of the Input Cable and Link Cables.

Connect the Input Cable to the input connector and connect the leads on the end of the Input 

Cable to an external device.

Connect the output and input connectors of the Light Units with Link Cables. Also connect the Input 

Cable to the input connector and connect the leads on the end of the Input Cable to an external device.

Turn ON the power supply.

Turn ON the power supply.

Changing from Constant Lighting Mode to Overdrive Mode

1) Set the ON/OFF inputs from the external device to the status for turning ON the Light Unit in Constant Lighting Mode. 

    Refer to 

7. ON/OFF Inputs

 for information on the ON/OFF input.

2) Change the operating modes in order from the Light Unit that is farthest from the power supply.

    (In the above figure, the order would be Light Unit A, Light Unit B, and then Light Unit C.)

   Refer to 

3. Names and Functions of Parts

 for information on changing the operating mode. If the setting status of the 

    ON/OFF inputs is not correct, an overdrive error will occur when you change the operating mode. Also, if the order is not 

    correct, an overload error will occur.

Changing from Overdrive Mode to Constant Lighting Mode

1) Change the operating modes in order from the Light Unit that is nearest to the power supply.

    (In the above figure, the order would be Light Unit C, Light Unit B, and then Light Unit A.)

    Refer to 

3. Names and Functions of Parts

 for information on changing the operating mode. If the order is not correct, 

    an overload error will occur. The setting status of the ON/OFF inputs is not relevant.

To external device

Input Cable

Link Cable

Link Cable

Light Unit A

Light Unit B

Light Unit C

Sealing Cap

(for LDLB-IP Series)

When you daisy-chain Light Units, you must use the operating panel on each Light Unit to change between Constant 

Lighting Mode and Overdrive Mode. Use the following procedure to change the operating mode.

To external device

Input Cable

Sealing Cap

 (for LDLB-IP Series)

Connection Example

LDLB Light Unit

External Circuit

Variable power supply

(0 to 10 VDC)

24 VDC

* You can adjust the light intensity with a variable power supply or a variable resistor.

*

If you use a variable power supply, use a power supply with a sinking 

output of 3 mA minimum per Light Unit.

Pin 5

Pin 3

If you use a variable resistor, use the one specified below.

    One Light Unit: 15 kΩ

    Two Light Units: 10 kΩ

    Three Light Units: 5 kΩ

Do not exceed an allowable difference of 20% in the overall resistance.

Note: According to product specifications, the light intensity that is set on 

          the operating panel may be used when the resistance is near the 

          maximum value.

If pin 5 (analog input) and pin 3 (common ground) are not connected on the input connector or if 13 to 24 V (maximum in-

put voltage: 26.4) is input, you can use the + and − switches on the operating panel to manually set the light intensity.

If 0 to 10 V is applied between pin 5 (analog input) and pin 3 (common ground) on the input connector, you can set the light 

intensity to any of 100 levels with the voltage of the analog input.

The light intensity is displayed on the digital display between 00 and 99 

(100 levels).

If you hold down the + or − key for more than 1 second, the value will 

change faster.

The manually set light intensity is saved internally even after you turn 

OFF the power supply or after you change to external light intensity 

control with an analog input.

The light intensity is displayed on the digital display between 00 and 99 (100 levels).

To maintain the light intensity, continue to input a constant voltage. The light intensity that is set by the analog input is not 

stored in the Light Unit.

Note: Depending on the number of connected Light Units and the cable length, different light intensities may be set for the same analog 

input voltage.

Note: The digital display will show "--" if the light is turned OFF in Constant Lighting Mode. If you turn the light ON and OFF repeatedly over 

a short period of time, the digital display may not display numbers correctly.

MODE

OverDrive

Continuous : Hold down

L

E

V

E

L

O/D

Con

Input Connector (M12 Plug) Configuration

Setting the Light Intensity with an Analog Input

Voltage (V) between Pin 5 and 3

Li

gh

t i

nt

en

si

ty

0

99

20

40

59

79

2

4

6

8

10

5

4

1

3

2

3

Set the operating modes of the Light Units.

Operating 

Panel

Input Connector (M12 Plug)

The digital display shows the light in-

tensity between 00 and 99.

(“00” is the minimum light level.)

You can manually set the light intensity 

with the + and 

 switches. Refer to 

5. 

Setting the Light Intensity on the Oper-

ating Panel

 for details.

You can change the operating mode 

by holding down the + and − switches 

at the same time for 3 seconds.

This connector is used to supply 

power to the Light Unit and to input 

signals to control the light intensity 

and turn the light ON and OFF.

Note: There are no restrictions in the installation 

direction. You can install the Light Unit up-

side down or in any other direction. Refer to 

10. Dimensions

 for the installation holes.

Using LDLB-IP-series 

Light Units

If you do not use this con-

nector, always attach a 

Sealing Cap to it to main-

tain water resistance.

Output Connector (M12 Socket)

If you daisy-chain Light Units, this 

connector is connected to the input 

connector on the next Light Unit with 

a Link Cable.

If you daisy-chain Light Units, you can 

supply power, control the light intensity 

with an analog input, and use an ON/

OFF input to control all of the Light Units 

together. You can also control the light 

intensity of the Light Units individually 

from the operating panels. You can con-

nect up to three Light Units.

A Link Cable (model: FECB-0.6-M12-

5M-5F, 0.6 m) is available as an option 

(sold separately).

The LDLB-IP-series Light Units maintain IP67 

water resistance when this Cable is connected.

Input Cables (models: FECB-M12-5F 

Series, 1, 2, 3, and 5 m, flying leads) are 

available as options (sold separately).

The LDLB-IP-series Light Units maintain IP67 

water resistance when this Cable is connected.

Light-emitting Surface

Digital Display

Mode Indicator

(Top panel)

Pin 

No.

Signal

Cable

FECB-M12-

5F Series

Wire color

1

24 VDC

Brown

2

ON/OFF input (NPN)

White

3

Common ground

Blue

4

ON/OFF input (PNP)

Black

5

Analog input (0 to 10 V)

Gray

Pin 

No.

Signal

Cable

FECB-M12-

5F Series

Wire color

1

24 VDC

Brown

2

ON/OFF input (NPN)

White

3

Common ground

Blue

4

ON/OFF input (PNP)

Black

5

Analog input (0 to 10 V)

Gray

Light intensity

00

01

49

50

98

99

Radiant 

quantity

Constant Lighting Mode 10%

11%

55%

55%

99% 100%

Overdrive Mode

100% 102%

214% 216%

328% 330%

5

5

4

3

1

2

3

4

2

1

Refer to 

9. Optional Products (Sold Sep-

arately)

 for details on the Link Cable.

Refer to 

6. External Control of the 

Light Intensity

 for information on the 

analog input.

Refer to 

7. ON/OFF Inputs

 for informa-

tion on the ON/OFF inputs.

Refer to 

9. Optional Products (Sold Sepa-

rately)

 for details on the Input Cable.

Label (Example)

Name label (Example)

The general relationship between the light intensity and the radiant quantity is shown in the following table.

Constant Lighting Mode

You can set the light intensity to any of 

100 levels from the operating panel or with 

an analog input from the input connector. 

You can turn the light ON and OFF with an 

ON/OFF input from the input connector.

Overdrive Mode

The mode indicator on the operating 

panel will light. A larger current en-

ables a brighter light intensity (100 lev-

els) than in Constant Lighting Mode.

However, the light intensities that you 

can set are restricted as shown below. 

Refer to 

7. ON/OFF Inputs

 for details.

   Operating time

   Signal repeat period to light the LEDs

Wire diameter

Number of Light Units connected in Constant Lighting Mode

Number of Light Units connected in Overdrive Mode

1

2

3

1

2

3

AWG16

10 m

10 m

10 m

10 m

5.5 m

2 m

AWG18

10 m

10 m

10 m

8 m

3.5 m

1.5 m

AWG20

10 m

10 m

7 m

5.5 m

2 m

Cannot be used.

AWG22

10 m

7 m

4.5 m*

3 m*

1 m*

Cannot be used.*

* The wire diameter is AWG22 for the optional (sold separately) FECB-M12-5F-series Input Cables and FECB-0.6-M12-5M-5F Link Cable. If the 

   maximum length given above is exceeded, shorten the Input Cable or contact CCS.

− switch

+ switch

Digital display

All manuals and user guides at all-guides.com

all-guides.com

Reviews: