- 2 -
Signal from a Sinking Input (NPN)
You can turn the light ON and OFF with a signal input from the input connector. With these Light Units, you can use a
sinking input (NPN) or a sourcing input (PNP).
Pin 4 Open
Constant Lighting Mode
Connection Example
Pin 4 High Voltage
Overdrive Mode
Light Unit status
Pin 2 (NPN)
Lit.
Lit.
Low voltage
Open
ON delay time: 55 us max.
OFF delay time: 45 us max.
Not lit.
Minimum operating time:
Approx. 100 us
Light Unit status
Pin 2 (NPN)
Lit.
Lit.
Low voltage
Open
ON delay time: 55 us max.
OFF delay time: 45 us max.
Not lit.
Minimum operating time:
Approx. 100 us
Pin 2 (NPN)
Low voltage
Open
Light Unit status
Not lit.
Not lit.
OFF delay time: 45 us max.
Lit.
ON delay time: 55 us max.
Minimum operating time:
Approx. 100 us
Pin 2 (NPN)
Low voltage
Open
Light Unit status
Not lit.
Not lit.
OFF delay time: 45 us max.
Lit.
ON delay time: 55 us max.
Minimum operating time:
Approx. 100 us
LDLB Light Unit
External Circuit
Pin 4
Pin 3
Pin 2
Transistor (NPN)
open collector
LDLB Light Unit
External Circuit
5 VDC
24 VDC
Pin 4
Pin 3
Pin 2
Transistor (NPN)
open collector
5 VDC
*
*
Switch the signal input on pin 2 to turn the light ON and OFF with a signal from a sinking input (NPN). Also, you can input
a high voltage on pin 4 to switch the logic for turning the light ON and OFF.
Switch the signal input on pin 4 to turn the light ON and OFF with a signal from a sourcing input (PNP). Also, you can input
a low voltage on pin 2 to switch the logic for turning the light ON and OFF.
* Use an element or switch with a current flow of approximately 1 mA in the external circuit.
Logic Table
Refer to the following table for the low and high voltages.
Logic switching
Pin 4
Open
High voltage
Signal input
Pin 2 (NPN)
Open
Low voltage
Open
Low voltage
Operating
mode
Constant Lighting Mode
Lit.
Not lit.
Not lit.
Lit.
Overdrive Mode
Not lit.
Lit.
Lit.
Not lit.
Logic switching
Pin 2
Open
Low voltage
Signal input
Pin 4 (PNP)
Open
High voltage
Open
High voltage
Operating
mode
Constant Lighting Mode
Lit.
Not lit.
Not lit.
Lit.
Overdrive Mode
Not lit.
Lit.
Lit.
Not lit.
Pin
Signal input status
Range
Pin 2 (NPN)
Low voltage
0 to 1.1 VDC
Pin 4
High voltage
20.7 to 26.4 VDC
Pin
Signal input status
Range
Pin 2
Low voltage
0 to 1.1 VDC
Pin 4 (PNP)
High voltage
20.7 to 26.4 VDC
Transistor
(NPN)
Pin 2
Pin 3
(ground)
Switch,
relay, etc.
Pin 2
Pin 3
(ground)
Signal from a Sourcing Input (PNP)
Pin 2 Open
Constant Lighting Mode
Connection Example
Pin 2 Low Voltage
Overdrive Mode
LDLB Light Unit
External Circuit
5 VDC
24 VDC
Pin 4
Pin 3
Pin 2
Transistor (PNP)
open collector
*
LDLB Light Unit
External Circuit
5 VDC
24 VDC
Pin 4
Pin 3
Pin 2
Transistor (PNP)
open collector
*
Pin 4 (PNP)
High voltage
Open
Lit.
Light Unit status
Lit.
OFF delay time: 45 us max.
Not lit.
ON delay time: 55 us max.
Minimum operating time:
Approx. 100 us
Pin 4 (PNP)
High voltage
Open
Lit.
Light Unit status
Lit.
OFF delay time: 45 us max.
Not lit.
ON delay time: 55 us max.
Minimum operating time:
Approx. 100 us
Light Unit status
Pin 4 (PNP)
Not lit.
Not lit.
High voltage
Open
ON delay time: 55 us max.
OFF delay time: 45 us max.
Lit.
Minimum operating time:
Approx. 100 us
Light Unit status
Pin 4 (PNP)
Not lit.
Not lit.
High voltage
Open
ON delay time: 55 us max.
OFF delay time: 45 us max.
Lit.
Minimum operating time:
Approx. 100 us
* Use an element or switch with a current flow of approximately 1 mA in the external circuit.
Logic Table
Refer to the following table for the low and high voltages.
Pin 4
Pin 3
(ground)
Switch,
relay, etc.
Pin 4
Pin 3
(ground)
Transistor
(PNP)
Optional Products (Sold Separately)
9
Error Displays
8
If an error occurs, it will be shown on the digital display on the operating panel.
Digital display
Status
E1
Overdrive error
In Overdrive Mode, the operating time or the ON signal repeat period limit was exceeded. This
error is shown on the digital display for 3 seconds. The mode indicator on the upper left of the
digital display will flash continuously.
(The mode indicator will stop flashing when you change to Constant Lighting Mode or when you
cycle the power supply.)
E2
Overload error
An overload occurred, e.g., four or more Light Units were connected.
Outputting light will be stopped and automatic recovery will be attempted after 3 seconds.
Restrictions in Overdrive Mode
Depending on the set light intensity, the operating time and the repeat period of the signal that lights the Light Unit (i.e., the
ON signal) are restricted. Input ON signals that meet the conditions given in the following table.
*1 If the ON signal exceeds the above operating time (T
L
),
the light will be turned OFF automatically.
*2 If the ON signal is input in less time than the above
period, it will be ignored.
Light intensity
Operating time (T
L
)
*1
ON signal repeat period
*2
0 to 28
125 ms max.
At least 6.7 times the operating time
29 to 99
10 ms max.
At least 14.3 times the operating time
If the ON signal is input continuously, the light will repeatedly turn ON and OFF.
Light Unit
status
ON signal
6.7 or 14.3 times T
L
6.7 or 14.3 times T
L
6.7 or 14.3 times T
L
Not lit.
Lit.
Not lit.
Lit.
Lit.
Not lit.
Not lit.
ON delay time: 55 us max.
T
L
: Operating time
(125 ms max. or 10 ms max.)
: Invalid ON signals
T
L
T
L
T
L
ON delay time: 55 us max.
ON delay time: 55 us max.
Common Specifications
Specifications by Model
Main Specifications
11
Input voltage (rating)
24 VDC
Input voltage (range)
22.8 to 26.4 VDC
Input current (rating)*
Constant lighting mode: 1.3A max.
Overdrive mode: 6A max.
Input connector
M12 (5 pins, plug)
Output connector
M12 (5 pins, socket)
Lighting mode
Constant lighting mode, overdrive mode
Inrush current (max.)
6 A from a cold start
Insulation withstand voltage
(input and output-case)
250 VAC for one minute, cutoff current: 10 mA,
500 VDC, 1MΩ min.
Operating temperature
and humidity (indoors only)
Temperature: 0 to 40°C, Humidity: 20% to
85% (with no condensation)
Storage temperature
and humidity
Temperature: −20 to 60°C, Humidity: 20%
to 85% (with no condensation)
Vibration resistance
Acceleration: 19.6 m/s
2
, frequency: 10 to 55 Hz,
cycles: 3 minutes,sweep cycle: for 1 hour
each in X, Y, and Z directions
Shock
Acceleration: 800 m/s
2
, Application time: 11 ms,
Repetitions: 3 times each in 6 directions
Cooling method
Natural air cooling
CE Marking
Safety standard: Conforms to EN62471
EMS standard: Conforms to EN61000-6-2
EMI standard: Conforms to EN61000-6-4
Environmental regulations RoHS compliant
Case material
Aluminum alloy, resin
Weight
500 g
Accessories
Instruction Guide
Model
LED
color
Peak wavelength /
Correlated color
temperature (typ.)
Power
consumption
(W)(max.)
Protective
structure
LDLB-300SW-N White
6100 K
31
-
LDLB-300RD-N
Red
630 nm
24
-
LDLB-IP-300SW-N White
6100 K
31
Conforms to IP67
(JIS C 0920)
LDLB-IP-300RD-N
Red
630 nm
24
Conforms to IP67
(JIS C 0920)
* Recommended tightening torque: 0.7 N·m
*
* The dimensions shown on the left include
tolerance. If you mount two Light Units with
their short sides adjacent to each other, you
can separate the centers of the installation
holes by 8 mm to eliminate misregistration.
4 x Ø4.5
(For installation)
313
304
63
3.
5
3.5
Sealing Cap: PROT-M12 (PHOENIX CONTACT)
(For LDLB-IP Series)
300 (
発光面
)
24 (
Em
itt
in
g s
ur
fa
ce
)
10
320
70
11
Bottom view
Rear view
Top view
8
32
Side view
8
(0.6)
54
8
8
Headquarters
Address any product queries to the following address or to your nearest CCS representative.
* The power supply for daisy-chained Light Units must provide
sufficient output for all of the Light Units.
7
10
7
ON/OFF Inputs
Dimensions
ON/OFF Inputs
(Continued)
Light Unit
status
ON signal
T
L
6.7 or 14.3 times T
L
Not lit.
Lit.
Lit.
Not lit.
Not lit.
Light Unit
status
Not lit.
Not lit.
ON signal
ON delay time: 55 us max.
OFF delay time: 45 us max.
Lit.
T
L
Input Connector (M12 Plug) Configuration
5
4
1
3
2
Pin No.
Signal
Cable
FECB-M12-5F Series
Wire color
1
24 VDC
Brown
2
ON/OFF input (NPN)
White
3
Common ground
Blue
4
ON/OFF input (PNP)
Black
5
Analog input (0 to 10 V)
Gray
EXCEPT FOR THE EXPRESS WARRANTIES STATED IN THIS DOCUMENT, CCS MAKES NO
ADDITIONAL WARRANTIES, EXPRESS, IMPLIED, OR STATUTORY, AS TO ANY MATTER
WHATSOEVER. IN PARTICULAR, ANY AND ALL WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.
EXCEPT AS EXPRESSLY SET FORTH HEREIN, CCS MAKES NO WARRANTIES WITH RE-
SPECT TO THE PRODUCTS.
WARRANTY PERIOD: TWO YEARS (ONE YEAR FOR RADIANT QUANTITY), STARTING
FROM CCS Inc. SHIPPING DATE.
CCS Inc. WILL REPAIR OR REPLACE THE PRODUCT FREE OF CHARGE IF IT SHOULD
FAIL TO FUNCTION OR IF THE RADIANT QUANTITY OF THE PRODUCT SHOULD DROP
TO 50% OR LESS OF ITS INITIAL RADIANT QUANTITY WITHIN THE SPECIFIED WARRAN-
TY PERIOD. IF EITHER OF THESE CONDITIONS OCCURS, PLEASE TAKE THE PRODUCT
TO YOUR CCS SALES REPRESENTATIVE.
WARRANTY TERMS
1 CCS Inc. WILL REPAIR OR REPLACE THE PRODUCT FREE OF CHARGE IF IT SHOULD
FAIL TO FUNCTION UNDER USE ON OUR SPECIFIED CONDITION IN ACCORDANCE
WITH THE INSTRUCTION GUIDE AND OTHER WRITTEN CAUTIONS DURING THE INDI-
CATED WARRANTY PERIOD OF TWO YEARS.
2 CCS Inc. WILL REPAIR OR REPLACE THE PRODUCT FREE OF CHARGE IF ITS RADIANT
QUANTITY SHOULD DROP TO 50% OR LESS OF ITS INITIAL RADIANT QUANTITY UN-
DER USE ON OUR SPECIFIED CONDITION IN ACCORDANCE WITH THE INSTRUCTION
GUIDE AND OTHER WRITTEN CAUTIONS DURING THE INDICATED WARRANTY PERI-
OD OF ONE YEAR.
3 CCS Inc. WILL CHARGE A REPAIR FEE UNDER THE FOLLOWING CONDITIONS:
1) IF THE PRODUCT HAS BEEN SUBJECTED TO MISUSE, UNAUTHORIZED REPAIRS,
OR MODIFICATION FROM ITS ORIGINAL DESIGN.
2) IF THE PRODUCT HAS BEEN DAMAGED FROM IMPACTS DUE TO INAPPROPRIATE HAN-
DLING.
3) IF DAMAGE TO THE PRODUCT RESULTS FROM EXTERNAL CAUSES INCLUDING
ACCIDENTS, FIRE, POLLUTION, RIOTS, COMMUNICATION FAILURES, EARTH-
QUAKES, THUNDERSTORMS, WIND AND FLOOD DAMAGE, OR ANY OTHER ACT OF
PROVIDENCE, OR FROM ANY EXTRAORDINARY CONDITIONS SUCH AS ELECTRICAL
SURGES, WATER LEAKAGE, CONDENSATION, OR THE USE OF CHEMICALS.
4) IF THE DAMAGE RESULTS FROM CONNECTION TO ANY Control Unit OR TO ANY EQUIPMENT
WHICH CCS Inc. DOES NOT MANUFACTURE OR DOES NOT SPECIFY FOR USE.
4 CCS ASSUMES NO LIABILITY FOR ANY PURCHASER’S SECONDARY DAMAGE (DAMAGE OF
EQUIPMENT, LOSS OF OPPORTUNITIES, LOSS OF PROFITS, ETC.) OR ANY OTHER
DAMAGE RESULTING FROM A FAILURE OF OUR PRODUCT.
THIS WARRANTY INFORMATION PROVIDES THE SCOPE OF CCS'S PRODUCT WARRAN-
TY WITHIN THE SPECIFIED PERIOD, AND DOES NOT INDICATE OR IMPLY ANY FURTHER
GUARANTEE BEYOND THE WARRANTY TERMS.
CONTACT CCS FOR INQUIRIES OR INFORMATION ON REPAIRS TO THE PRODUCT AF-
TER THE EXPIRATION OF THE WARRANTY.
NOTE: THE RADIANT QUANTITY REFERS TO THE WATTAGE OF PHYSICAL ENERGY RADIATED
FROM AN LED. IT REFERS TO THE RADIATION LUMINOSITY OF THE LED MEASURED
UNDER CONDITIONS SPECIFIED BY CCS OR THE RADIATION ILLUMINATION OF THE LED
UNDER SPECIFIED IRRADIATION CONDITIONS. CCS SPECIFIES THE RADIANT QUANTITY
FOR EACH LED LIGHT BECAUSE THE MEASUREMENT AND IRRADIATION CONDITIONS
VARY FROM THE FORM, THE APPLICATION AND THE IRRADIATION WAVELENGTH.
Warranty Information
Copyright© 2016 CCS Inc. All Rights Reserved.
Descriptions in this instruction guide are based on information available as of July 2016. KZ06922-T001-003
Shimodachiuri-agaru, Karasuma-dori, Kamigyo-ku,Kyoto 602-8011 Japan
E-mail : [email protected]
Phone : +81-75-415-8284 Fax : +81-75-415-8278
Use our website to find your nearest CCS representative.
http://www.ccs-grp.com/mvad
Contents of this Instruction Guide may be changed without prior notice.
Illustrations used in this Instruction Guide may differ from actual products.
CCS maintains the copyright on this Instruction Guide. Unauthorized transfer or reproduction is strictly prohibited.
Instruction Guide and Dimensional Diagrams in PDF or CAD can be downloaded from the CCS website. http://www.ccs-grp.com
Information Required for China RoHS Directive
环保
使用期限
产品
有害物质的名称及含量
铅
(Pb)
汞
(Hg)
镉
(Cd)
六价铬
(Cr(VI))
多溴联苯
(PBB)
多溴二苯醚
(PBDE)
LED 照明
( 本表格依据 SJ/T11364 的规定编制。)
:
表示该有毒有害物质在该部件所有均质材料中的含量均在 GB/T26572 标准规定的限量要求以下。
:
表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 GB/T26572 标准规定的限量要求。
( 注 ) 铅和镉中的“×”,因欧洲 RoHS 没限定,故用“○”表示。
Usage deadline for environmental protection
The number used in this logo is based on “Management Methods for Restricting Hazardous Substances Used
in Electric and Electronic Products” and related regulations from People’s Republic of China. It shows the
product usage duration in years for environmental protection. After finishing a product usage, the product
needs to be re-used or discarded appropriately following local law and regulations, complying with safety and
usage caution.
Usage Deadline
for Environmental
Protection
Product
name
Names and contents of hazardous substances
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
chromium (Cr(VI))
PBB
PBDE
LED
Lights
(This table is made in compliance with SJ/T11364 regulations.)
: Indicates that this toxic or hazardous substances contained in all the homogeneous
materials for this part, according to GB/T26572 is within the limit requirement.
: Indicates that this toxic or hazardous substance contained in all the homogeneous materials
for this part, according to GB/T26572, is over the limit requirement.
*Lead and cadmium are excluded in EU RoHS.
Names and contents of hazardous substances
产品中有害物质的名称及含量
环保使用期限
此标志的数字是根据中华人民共和国电器电子产品有害物质限制使用管理办法以及有关标准等,表示该产品的环
保使用期限的年数。
遵守产品的安全和使用上的注意,在产品使用后采取适当的方法根据各地法律,规定,回收再利用或进
行废弃处理。
Ø
14
.8
44
n x 1000
50
(Ø
5.1
)
(n=1, 2, 3, 5)
(Unit: mm)
(Unit: mm)
Light Unit (input connector)
(Socket)
Input connector
(Socket)
Output connector
(Plug)
Flying leads
(5 wires, AWG22)
Ø
14
.8
(Ø
5.1
)
Ø14
.8
44
600
46.8
Input Cable
Link Cable
Model: FECB-n-M12-5F
Model: FECB-0.6-M12-5M-5F
This cable is used to supply power to the Light Unit and to input sig-
nals to control the light intensity and turn the light ON and OFF.
Use this cable for daisy-chain connections.
Select the required cable length.
Weight: 50 g max.
Model FECB-1-M12-5F FECB-2-M12-5F FECB-3-M12-5F FECB-5-M12-5F
Length
1 m
2 m
3 m
5 m
Weight
55 g max.
90g max.
130g max.
210g max.
All manuals and user guides at all-guides.com