background image

13

Heat Index range

Warning

Explanation

27°C to 32°C

(80°F to 90°F)

Caution

Possibility of heat exhaustion

33°C to 40°C

(91°F to 105°F)

Extreme Caution

Possibility of heat dehydration

41°C to 54°C

(106°F to 129°F)

Danger

Heat exhaustion likely

≥55°C (≥130°F)

Extreme Danger

Strong risk of dehydration / sun stroke

Note: 

Heat index is only calculated when temperature is 27° C (80° F) or above, and based solely from the 

temperature and humidity measured from the 5-IN-1 sensor.

TO VIEW DEW POINT

Press the 

[ INDEX ]

 key repeatedly until 

DEW POINT

 displays.

Note: 

The dew point is the temperature below which the water vapor in air at constant barometric pressure 

condenses into liquid water at the same rate at which it evaporates. The condensed water is called dew when 

it forms on a solid surface. The dew point temperature is calculated from the outdoor temperature and humidity 

measured at the outdoor 5-in-1 sensor.

HISTORY DATA (ALL RECORDS IN THE PAST 24 HOURS)                                                                               

The main unit will record past 24 hours weather data automatically that included past indoor and outdoor 

temperature & humidity, baro, wind chill, wind speed and rainfall records.

1. Press the 

[ HISTORY ]

 key to check past 1 hour history records.

2. Press 

[ HISTORY ]

 key repeatedly to show past 2, 3, 4 , 5.......24 history weather records.

MAX/MIN MEMORY FUNCTION                                                                                                                            

1. Press the 

MAX/MIN

 key to check the maximum/minimum records. The checking orders will be: Outdoor 

max temperature 

 Outdoor min temperature 

 Outdoor max humidity 

 Outdoor min humidity  

 Indoor max temperature 

 Indoor min temperature 

 Indoor Max humidity

 Indoor min 

humidity 

 Outdoor max wind chill 

 Outdoor min wind chill  Outdoor max heat index 

 Outdoor 

min heat index 

  max dew point 

 min dew point 

 Max pressure 

 Min pressure 

 Max 

average 

 Max gust 

 Max rainfall.

2. Press and hold the

 [ MAX/MIN ] 

key for 2 seconds to reset the maximum and minimum records.

Note: 

When maximum or minimum reading is displayed, the corresponding timestamp will be shown.

HI/LO ALERT                                                                                                                                                          

HI/LO alert are used to alert you of certain weather conditions. Once activated, the alarm will turn on and 

amber LED starts flashing when a certain criterion is met. The following are areas and type of alert provided:

Area

Type of Alert available

Indoor temperature

HI and LO alert

Indoor humidity

HI and LO alert

Outdoor temperature

HI and LO alert

Outdoor humidity

HI and LO alert

Rainfall

HI alert 

 

(Daily rainfall since midnight)

Wind speed

HI alert

Summary of Contents for C8479B

Page 1: ...1 PROFESSIONAL Colour WEATHER STATION WITH 5 IN 1 SENSOR Model C8479B USER MANUAL...

Page 2: ...PEED WIND DIRECTION 11 WIND CHILL HEAT INDEX DEW POINT 12 HISTORY DATA ALL RECORDS IN THE PAST 24 HOURS 13 MAX MIN MEMORY FUNCTION 13 HI LO ALERT 13 WIRELESS SIGNAL RECEPTION 14 TEMPERATURE HUMIDITY 1...

Page 3: ...er when the set high or low weather criteria are met The barometric pressure records are computed to give users forthcoming weather forecast and stormy warning Day and date stamps are also provided to...

Page 4: ...6 HISTORY key 17 SENSOR key 7 INDEX key 18 RCC key 8 LCD display 19 RESET key 9 AAA battery compartment 20 key 10 Power jack Temperature sensor 21 key 11 Wall mounting hole 22 Extend wall mount holder...

Page 5: ...NSOR 1 Wind cups anemometer 2 Wind vane 1 2 2 LCD DISPLAY NORMAL TIME AND CALENDAR SECTION 1 Day of the week 2 Low battery indicator for main unit 3 Time 4 DST 5 RCC signal strength indicator 6 Alarm...

Page 6: ...dicator 2 Time range record indicator 3 Day records indicator 4 HISTORY 5 Hi Alert and Alarm 6 Current rainfall rate 7 Rainfall unit inch mm 3 4 2 1 5 6 7 WIND DIRECTION 1 WIND DIRECTION indicator 2 C...

Page 7: ...around the sensor for accurate rain and wind measurement Install the sensor with the smaller end facing the North to properly orient the wind direction vane Secure the mounting stand and bracket inclu...

Page 8: ...the sensor Note Pressing RESET key at bottom of wireless 5 IN 1 sensor will generate a new code for pairing purpose Always dispose old batteries in an environmentally safe manner RADIO CONTROLLED ATO...

Page 9: ...he ALARM key anytime to show the alarm time 2 Press the ALARM key to activate the alarm 3 Press again to activate alarm with ice alert function 4 To disable the alarm press until the alarm icon disapp...

Page 10: ...spheric pressure When you change the relative atmospheric pressure value the weather indicators will change along with it The relative atmospheric pressure is based on the sea level but it will change...

Page 11: ...m h TO SELECT WIND SPEED UNIT 1 Press and hold the key for 2 seconds to enter unit setting mode 2 Use key key to change the unit between mph miles per hour m s meter per second km h kilometer per hour...

Page 12: ...ome branches break off trees and some small trees blow over Construction temporary signs and barricades blow over 47 54 mph 41 47 knot 20 8 24 4 m s 10 Storm 89 102 km h Trees are broken off or uproot...

Page 13: ...wind speed and rainfall records 1 Press the HISTORY key to check past 1 hour history records 2 Press HISTORY key repeatedly to show past 2 3 4 5 24 history weather records MAX MIN MEMORY FUNCTION 1 Pr...

Page 14: ...rm automatically turn off after 2 minutes WIRELESS SIGNAL RECEPTION No sensor Signal searching Strong signal Weak signal Signal lost The 5 IN 1 sensor is capable of transmitting data wirelessly over a...

Page 15: ...n the Display main unit press and hold the WIND key for 8 seconds until the upper part Northern Hemisphere of the compass lights up and blinking 3 Use key key to change to lower part Southern Hemisphe...

Page 16: ...d Direction 1 Check wind cups Anemometer 2 Check the wind vane and Signal lost for 15 minutes 1 Relocate the main unit and 5 in 1 sensor closer to each other 2 Make sure the main unit is placed away f...

Page 17: ...F or MSF base on the country version DST AUTO OFF INDOOR BAROMETER Barometer unit hPa inHg and mmHg Measuring range 540 1100hPa Accuracy 700 1100hPa 5hPa 540 696hPa 8hPa 20 67 32 48inHg 0 15inHg 15 95...

Page 18: ...ll mm and in Range for rainfall 0 9999mm 0 393 7inches Resolution 0 4 mm 0 0157 in Accuracy for rainfall Greater of 7 or 1 tip Memory modes Max rainfall from last memory reset Historical data for last...