![CCi PiMPro Tower 1821 User Manual Download Page 4](http://html.mh-extra.com/html/cci/pimpro-tower-1821/pimpro-tower-1821_user-manual_2575789004.webp)
8/7/2018
Rev. 1.0
4
Tower Series PIM Analyzer Remote
Operation User Guide
Table 1 - Tower Series PIM Analyzer Specifications
Description
Typical Specifications
Electrical Specifications
Frequency Bands
Receive Range (MHz)
Transmit Range (MHz)
LTE 700 (Tower Series Dual Band 700)
698 - 722 (RX1), 780 - 798 (RX2)
745.6 - 769.4 (TX1), 732.6 - 734.4 (TX2)
APT 700 (Tower Series Dual Band 700A)
703 - 748 (RX1), 825 - 845 (RX2)
758 - 776 (TX1), 788 - 807 (TX2)
LTE 800 (Tower Series 800)
832 - 862
811 - 821 (TX1), 791 - 795 (TX2)
Cellular 850 (Tower Series 850)
824 - 849
864 - 871 (TX1), 881.6 - 894 (TX2)
GSM 900 (Tower Series 900)
890 - 915
925 - 937.5 (TX1), 951.5 - 980 (TX2)
DCS 1800 / UMTS 2100 (Tower Series Dual Band 1821)
1710 - 1785 (RX1), 1920 - 1980 (RX2)
1805 - 1833 (TX1), 1855 - 1880 (TX2)
PCS/AWS (Tower Series Dual Band 1921)
1710 - 1755 (RX1), 1850 - 1910 (RX2)
1965 - 1995 (TX1), 1930 - 1945 (TX2)
2110 - 2155 (TX1)
LTE 2600 (Tower Series 2600)
2500
– 2570 (RX1)
2620 - 2644 (TX1) 2690 Fixed (TX2)
Transmitter
Frequency Accuracy:
±1 ppm @ +23°C; Stability ±1 ppm (-10°C to +55°C)
Frequency Aging:
±1 ppm/yr
Output Accuracy:
± 0.3 dB
Frequency Step Resolution:
± 200 KHz
Output Power Resolution:
± 0.1 dB
Adjustable Power Range:
20 to 46 dBm x 2 (100 mW
– 40 W x 2)
Receiver
Residual Intermod Level :
< -120 dBm (< -163 dBc at 20 W); -125 dBm (-168 dBc) Typical
Measurement Range:
-60 to -140 dBm
Noise Floor:
-136 dBm
Reverse Power Protection:
13 dBm (20 mW) continuous
Measurement Modes
Measurement Method:
One Port, Reverse PIM
Real Time PIM:
3
rd
and 5
th
order IMD
Return Loss:
Measured in dB
Frequency Sweep:
Frequency Response
PIM vs. Time:
3
rd
and 5
th
order IMD
RX Interference:
Receive Only Mode
– Noise Floor Measurements
Noise Floor Measurement:
Up-Link noise level with TX off
PIM Location (PiMPoint):
Distance to PIM Location in Feet or Meters with VP Settings
Distance to Fault/Cable Loss:
One Port Open-Short Calibration
DAS Feature:
Path Loss Characteristics (at Low Power over time)
Measurement Range
Return Loss:
Directivity >25 dB;
Resolution:
>0.1 dB
VSWR:
Measurement Range 17:1 to 1.12:1;
Resolution:
>0.01 dB
Cable Loss:
Measurement Range 0 to 30 dB;
Resolution:
>0.01 dB
Distance to Fault:
VSWR Range 17:1 to 1.02:1;
RL Range:
0 to 40 dB
System
Battery:
>3 hours (Full Charge)
Power:
AC (90 - 256 VAC, 50 - 60 Hz)
Alarms:
Audio & Visual Display
Display Size & Type:
8.” (203.2 mm) Capacitive TFT, Industrial Grade Screen
Data Ports:
3
– USB 2.0, 1 x Ethernet LAN Port
Remote Control:
WiFi Enabled (802.11n)
Control:
GUI Control Via Touch Screen Display
Battery Power:
28 VDC
Battery Capacity:
3.5 AH (99.4 WH)
Battery Type:
Li-Polymer Removable Battery Pack
Electrical
Max Power Consumption:
<340 W
Mechanical
Weight:
< 18 to 27 lbs. (8.5 to 12.5 kg) (Model Dependent)
RF Output Connector:
1 x 7/16 DIN Female
Dimensions (W × H × D):
14” × 9” × 4.5” (350 × 230 × 114 mm)
Operating Temperature:
-10
C to +45
C (14
F to 113
F), 95% RH
Storage Temperature:
-30
C to +60
C (-22
F to 140
F), 85% RH