TECHNICAL FEATURES 

 

General

 

Dimensions (wxhxd) in mm 
Weight 
Power supply voltage 
Protection index 
Insulation

 

 

300x1500x90 

2 kg 

230V / 50Hz  

IP-55 

Class II 

 

 
pH-metre 
Measuring range 
Measuring resolution 
Probe 
Calibration 
Correction (offset) 
 
Dosing pump  
Type  
Max. flow 
Dosing 
 
Volume control 

 

 

 

3.9 to 9.9 

+/- 0.1 

Combined electrode 

at pH 7 and pH9 

+/- 0.5 

 
 

Peristaltic 

1.8 l/h 

Proportional 0 to 0.9l/h  

 

Daily and total 

 

Accessories supplied

 

4 m cristal tube 
2 clamp saddles, 50 mm 
1 inlet filter and suction filter for the tank 
containing the solution 
1 cable for the connection to the filtration 
1 calibration solution at pH7  
1 calibration solution at pH9 
2 pH probes 
1 probe holder 
1 injector 
1 maintenance kit for the pump

 

Menu with a choice of 8 languages 

 

French, English, German, Spanish,

 

Italian, Portuguese, Dutch, Czech

 

 

Warning: This equipment is designed to provide metered doses of ph corrector especially 
for swimming pools. 
If it is to be used with another type of solution, please check the compatibility of the 
equipment with the manufacturer. 
Its use with hydrochloric acid at more than 10% solution is not recommended.

 

 

When the device is metering doses, the pump does not run continuously but for 
about 1 minute in 2.

 

Summary of Contents for PF10J027

Page 1: ...11 04 2016 CONTENTS TECHNICAL FEATURES 3 INTRODUCTION 4 OPERATION 4 Status menu 4 Settings menu 7 HYDRAULIC CONNECTION 8 pH probe installation 8 Injector installation 8 Installation diagram 9 ELECTRIC...

Page 2: ...User manual v1 1 PHILEO PRO CCEI page 2...

Page 3: ...tion filter for the tank containing the solution 1 cable for the connection to the filtration 1 calibration solution at pH7 1 calibration solution at pH9 2 pH probes 1 probe holder 1 injector 1 mainte...

Page 4: ...a pull down menu for viewing the status of the PHILEO S different variables Moreover this pull down menu is used to access the ADJUSTMENTS menu for adjusting the device THE STATUS MENU Scrolling throu...

Page 5: ...water pH exceeds the pH set point pH MODE for injecting an alkaline product and hence increasing pool pH The pump starts up when the pH of the water is less than the pH set point ON MODE For injectin...

Page 6: ...probe calibration This operation must be performed when starting up the PHILEO for the first time and then repeated about once a month There are two solutions supplied with the PHILEO to be used for...

Page 7: ...s different adjustment options To access the settings menu press the and keys The different displays are as follow Language This menu allows any one of 8 languages to be chosen for the PHILEO menu Fr...

Page 8: ...pH probe Use a clamp saddle the probe holder and the probe Any screwing must be done with TEFLON PH PROBE INSTALLATION The probe is designed for measuring and checking pool pH by sending information...

Page 9: ...nto the clamp saddle with TEFLON Clamp saddle to be fitted onto the piping INSTALLATION DIAGRAM The various PHILEO components to be onto the piping of the swimming pool are The pH probe which must be...

Page 10: ...ires of this connector must be connected to a dry contact of the filtration pump Dry contact means potential free and should be used only for one device If a CCEI filtration box is being used this dry...

Page 11: ...User manual v1 1 PHILEO PRO CCEI page 11...

Page 12: ...r The company Bleu Electrique FR 47403521693 declares that the PHILEO product satisfies the safety and electromagnetic compatibility requirements specified in European directives 2006 95 CE and 2004 1...

Reviews: