ELECTRICAL CONNECTION
Before connecting the PHILEO to the mains, check that the device is protected by a
30mA residual current device.
Supply must be permanent and fully protected from any eventual overvoltage or
under voltage.
The PHILEO dosing pump can function only when the filtration pump of the pool is in
operation. To this end, the PHILEO electrical box comes with a socket on the front and
a connector with 5 metres of cable.
Both wires of this connector must be connected to a dry contact of the filtration
pump. Dry contact means potential free and should be used only for one
device.
If a CCEI filtration box is being used, this dry contact can be taken from
terminals 7 and 8 (for GC type contactors) and terminals 13 and 14 (for LC1 type
contactors) if these terminals have not already been used.
N
I IN
multi9
S FT
6Aam
e
r
r
e
N
e
s
a
h
P
M
U1 U2 1 4 2
N
A B C D
Marche Forcée Interdit Pompe
In the case of a filtration box of a different make, this dry contact must be taken directly
from filtration contactor or a relay or an added parallel connection.
ATTENTION : The servoing connection to the filtration should never be shunted.