background image

ENGLISH                                                                                                            
 

 

Attached to TCITY Installation Manual 07/29/2021 

explosion. It might cause severe body 
injuries.

 

 

Do  not 

install  and  use  this 

product 

in 

hazardous 

environments 

(high 

risk 

of 

explosion). 

 

Installation and safety 

 

Handle  the  lamp  with  care  and 
avoid  having  it  drop  or  being  hit 
even  it  is  still  packed,  which 
might    cause  body  injuries,  as 
well as material damages. 

 

 Ensure  the  original  mounting 
accessories are used, as available 
from the manufacturer.  

 

Set  up  the  mounting  accessories 
properly. 

 

The equipment must be correctly 
fastened using the proper screws 
according  to  the  application, 
place  and  surface  where  the 
product is being mounted.   

 

Ensure  that  the  fastenings  are 
regularly checked. 

 

Danger  of  dazzling  glare  due  to  a 
white light source

  

Avoid  staring  directly  at  the  light 
source,  as  it  may  cause  a  temporary 
reduction  of  vision.  Irritation,  aches, 
damages  or  accidents  may  as  well 
occur. 

 

Avoid  staring  directly  at  the  light 
source. 

 

The  device  must  be  adjusted  so 
as  to  avoid  having  the  light  flow 
directed towards the eyes. 

 

Danger  caused  by  inappropriate 
spare parts. 

Using  inappropriate  spare  parts  may 
cause  bodily  injuries  and  material 
damages. 

 

Do not 

use spare parts that have 

not 

approved 

by 

the 

manufacturer. 

 

Damage  caused  by  the  presence  of 
laser beams 

Use  of  the  T-CITY  LED  lighting 
equipment 

is  not

  allowed  when  a 

high-power  laser 

  see:  a    laser 

cutting  system  -  is operating,  since  it 
may damage the LED source. 

 

Danger due to high temperatures   

Installing and using the equipment in 
all  the  environments  where  the 
existing 

temperature 

remarkably 

exceeds  the  foreseen  operating 
temperature will considerably reduce 
LED  lifetime  while  damaging  as  well 
the built-in electronic components. 

 

Do  not 

use  this  Device  in 

environments 

where 

the 

operating  temperature  of  the 
device is exceeded. 

 

Operating temperature -4/+113°F     
(-20/+45°C)

 

 

Avoid direct solar radiation. 

 

Danger due to repairs 

Having  the  product  disassembled  or 
repaired  without  any  appropriate 
technical  /electrical  knowledge  may 
cause  damages  to  persons  and 
objects. 

Safety Warnings 

Summary of Contents for T-City Series

Page 1: ...1 ENGLISH T City Series Installation Manual 24 VDC...

Page 2: ...ounting accessories 8 4 3 Installation 9 5 Plug in 11 5 1 Low voltage plug in with M12 connector 11 5 2 Power cord 12 5 3 Integrated Power Cord 12 6 Switch on Switch off 13 7 Problem solving 13 8 Ligh...

Page 3: ...ensure that the lamp remains perfectly sealed against any liquids The mounting brackets allow to easily adjust the flow beam direction up to 90 Waterproof LED lighting recommended for CNC EDM and tra...

Page 4: ...t is recommended only provided it is in perfect conditions and the user is well acquainted with all safety instructions CCEA the manufacturer waives any responsibility in case of product tampering or...

Page 5: ...the light source The device must be adjusted so as to avoid having the light flow directed towards the eyes Danger caused by inappropriate spare parts Using inappropriate spare parts may cause bodily...

Page 6: ...e manufacturer will null and void the warranty 2 3 Damage risk levels Dangers where noncompliance may immediately severe injuries and eventually lead to death Dangers where failure to satisfy requirem...

Page 7: ...ng equipment correctly and efficiently installed and used Note The product code is found on the brand name label stuck on the product s backside Find out the product code printed on the brand name lab...

Page 8: ...Symbol keys ENGLISH 8 4 Guide to installation 4 1 Product sizes and accessories 4 2 TFX01 side mounting brackets Guide to installation COD TFX01...

Page 9: ...side fasteners of chrome plated steel with M3 fixing screws and steel handle washers Direction of the luminous flux adjustable at 70 Installation with TFX01 side mounting brackets Hook the two side b...

Page 10: ...er Damaged or broken lamp When side mounting the lamp ensure to never completely loosen the M3 screws allowing for lamp rotation to avoid having the lamp fall down The side fasteners must be checked o...

Page 11: ...Wrong wiring may cause damages to the lamp All electrical connections have to be carried out by qualified electricians Please respect the polarity of connectors Always use the power cord supplied with...

Page 12: ...es A Coding connector female with pre assembled UL PVC Cable 4X0 75mmq Cross section PIN connection conductor 1 DC 24VDC brown 2 Not connected white 3 DC 0VDC blue 4 Not connected black Power cord DES...

Page 13: ...to replace the PCB LED if the lamp is properly installed and used following the instructions in this manual Please contact CCEA s Technical Support service or your Reseller in case the replacement of...

Page 14: ...ollowing different ways Any unauthorized repairs or attempts to repair the product Equipment operation under environmental conditions other than those specified in the user manual Liquid leakages insi...

Page 15: ...Please refer to the data printed on the label or engraved on the lamp Power supply 22 28 VDC Power input 6 12 18 24W see label IEC Class III Degree of protection IP67 compatible with NEMA type 12 LED...

Page 16: ...Symbol keys ENGLISH 16 14 Symbol keys CE Conformity marking Protection class III device Degree of protection IP67 IP67 WARNING Cancer and Reproductive Harm www P65Warnings ca gov...

Page 17: ...articular requirements part 4 Portable general purpose luminaries CEI EN 62031 LED modules for general lighting Safety specifications CEI EN 62384 DC or AC supplied electronic control gear for LED mod...