4.3 Installation 
 
 
 
 
The  lamp  fall-down  may  cause 
damage to persons and objects  

 

When mounting the lamp ensure 
that  the  original  fastenings  are 
used,  which  you  may  purchase 
from the supplier.

 

 

Have  the  fastening  accessories 
correctly mounted.

 

 
 
 
 
Switch  off  the  power  supply  before 
proceeding to installation.  
 
Correct  installation  using  only  the 
original fastenings TFX01 

The  T-CITY  mounting  accessories  are 
made of:

 

-

 

N.2  side  fasteners  of  chrome-
plated steel with M3 fixing screws 
and steel handle washers.    

-

 

Direction  of  the  luminous  flux 
adjustable at +/- 70°. 

 
 

 
 
 
 
 

Installation  with TFX01 side-
mounting brackets 
 

 

Hook  the  two  side  brackets  on 
the  lamp  sides  using  the  2 
screws provided.

 

 

 

Bore  the  fixing  holes  on  the 
machine  surface,  as  shown 
hereunder (Side mounting pitch): 

 

 
 
 

 
       Model 

 

-L- 

      TC012

 

      9.29

 (236mm) 

      TC022

             15.98

 (406mm) 

      TC032

             22.68

 (576mm)  

      TC042

             29.37

 (746mm)            

 

 

After  the  mounting  holes  have 
been  made,  fix  the  lamp  to  the 
machine  structure  using  M5 
screws of at least 8 mm. length (2 
screws  for  each  fastener).    The 
plate  where  the  lamp  will  be 
mounted has to be at least 2 mm 
thick. 

 
 
 
 
 
 
 
 
 
 

    

ATTENTION

 

  

 

WARNING 

Installation 

Summary of Contents for T-City Series

Page 1: ...1 ENGLISH T City Series Installation Manual 24 VDC...

Page 2: ...ounting accessories 8 4 3 Installation 9 5 Plug in 11 5 1 Low voltage plug in with M12 connector 11 5 2 Power cord 12 5 3 Integrated Power Cord 12 6 Switch on Switch off 13 7 Problem solving 13 8 Ligh...

Page 3: ...ensure that the lamp remains perfectly sealed against any liquids The mounting brackets allow to easily adjust the flow beam direction up to 90 Waterproof LED lighting recommended for CNC EDM and tra...

Page 4: ...t is recommended only provided it is in perfect conditions and the user is well acquainted with all safety instructions CCEA the manufacturer waives any responsibility in case of product tampering or...

Page 5: ...the light source The device must be adjusted so as to avoid having the light flow directed towards the eyes Danger caused by inappropriate spare parts Using inappropriate spare parts may cause bodily...

Page 6: ...e manufacturer will null and void the warranty 2 3 Damage risk levels Dangers where noncompliance may immediately severe injuries and eventually lead to death Dangers where failure to satisfy requirem...

Page 7: ...ng equipment correctly and efficiently installed and used Note The product code is found on the brand name label stuck on the product s backside Find out the product code printed on the brand name lab...

Page 8: ...Symbol keys ENGLISH 8 4 Guide to installation 4 1 Product sizes and accessories 4 2 TFX01 side mounting brackets Guide to installation COD TFX01...

Page 9: ...side fasteners of chrome plated steel with M3 fixing screws and steel handle washers Direction of the luminous flux adjustable at 70 Installation with TFX01 side mounting brackets Hook the two side b...

Page 10: ...er Damaged or broken lamp When side mounting the lamp ensure to never completely loosen the M3 screws allowing for lamp rotation to avoid having the lamp fall down The side fasteners must be checked o...

Page 11: ...Wrong wiring may cause damages to the lamp All electrical connections have to be carried out by qualified electricians Please respect the polarity of connectors Always use the power cord supplied with...

Page 12: ...es A Coding connector female with pre assembled UL PVC Cable 4X0 75mmq Cross section PIN connection conductor 1 DC 24VDC brown 2 Not connected white 3 DC 0VDC blue 4 Not connected black Power cord DES...

Page 13: ...to replace the PCB LED if the lamp is properly installed and used following the instructions in this manual Please contact CCEA s Technical Support service or your Reseller in case the replacement of...

Page 14: ...ollowing different ways Any unauthorized repairs or attempts to repair the product Equipment operation under environmental conditions other than those specified in the user manual Liquid leakages insi...

Page 15: ...Please refer to the data printed on the label or engraved on the lamp Power supply 22 28 VDC Power input 6 12 18 24W see label IEC Class III Degree of protection IP67 compatible with NEMA type 12 LED...

Page 16: ...Symbol keys ENGLISH 16 14 Symbol keys CE Conformity marking Protection class III device Degree of protection IP67 IP67 WARNING Cancer and Reproductive Harm www P65Warnings ca gov...

Page 17: ...articular requirements part 4 Portable general purpose luminaries CEI EN 62031 LED modules for general lighting Safety specifications CEI EN 62384 DC or AC supplied electronic control gear for LED mod...

Reviews: