background image

Symbol keys 

                                                                             ENGLISH 

 

 


 

2.

 

Safety instructions  

Each lighting device in the 

T-CITY 

series 

was 

designed 

and 

manufactured  based  on  state-of-
the-art techniques.              
It  is  made  of  well-selected,  high-
quality  materials.  It  is  carefully 
tested throughout the production 
process,  from  the  raw  material 
through to packaging, following a 
detailed  production  schedule  so 
as  to  guarantee  that  the  product 
is safe and reliable. 

Material damages, as well as body 
injuries,  may  nevertheless  still 
occur while using it. 

 
 
 
 

 

This  manual  is  part  of  the 

equipment  and  must  always 
be kept with it. 

 

Please  make  sure  that  ALL 

instructions/information 

in 

this manual are carefully read 
through  

 

Strict  compliance  with  the 

instructions  provided  in  this 
manual  and  on  the  lighting 
equipment is required  for its 
correct use   

 

Installation  and  use  of  the 

product  is  recommended 
only provided it is  in perfect 
conditions,  and  the  user  is 

well-acquainted 

with 

all 

safety instructions  

 

CCEA,  the  manufacturer,  waives 
any  responsibility  in  case  of 
product  tampering  or  improper 
use 

2.1 Proper use of the product 

This lighting equipment is fit for being 
installed inside machine tools, even in 
a wet environment. 
  

2.2 Product Safety 
 
Electrical Risks 

The  improper  and  incorrect  use  of 
the  equipment  may  cause  bodily 
injuries and material damages.  

 

All 

electrical 

connection 

procedures    must  be  carried  out 
by a licensed electrician  

 

Switch  off  the  power  supply 
before 

any 

installation, 

maintenance 

or 

reparation 

procedures. 

 

Please  ensure  that  the  power 
supply 

rated 

tension 

and 

frequency meets the requirements 
shown  on  the  product  label.  
Please respect cable polarity. 

 

Maintenance  and  reparations 
must  only  be  carried  out  by 
qualified electricians. 

 
Risk of explosion

  

Risk  of  explosion  might  occur    upon 
installing  and  using  this  product  for 
applications  with  a  high  risk  of 

Safety instructions 

Summary of Contents for T-City Series

Page 1: ...1 ENGLISH T City Series Installation Manual 24 VDC...

Page 2: ...ounting accessories 8 4 3 Installation 9 5 Plug in 11 5 1 Low voltage plug in with M12 connector 11 5 2 Power cord 12 5 3 Integrated Power Cord 12 6 Switch on Switch off 13 7 Problem solving 13 8 Ligh...

Page 3: ...ensure that the lamp remains perfectly sealed against any liquids The mounting brackets allow to easily adjust the flow beam direction up to 90 Waterproof LED lighting recommended for CNC EDM and tra...

Page 4: ...t is recommended only provided it is in perfect conditions and the user is well acquainted with all safety instructions CCEA the manufacturer waives any responsibility in case of product tampering or...

Page 5: ...the light source The device must be adjusted so as to avoid having the light flow directed towards the eyes Danger caused by inappropriate spare parts Using inappropriate spare parts may cause bodily...

Page 6: ...e manufacturer will null and void the warranty 2 3 Damage risk levels Dangers where noncompliance may immediately severe injuries and eventually lead to death Dangers where failure to satisfy requirem...

Page 7: ...ng equipment correctly and efficiently installed and used Note The product code is found on the brand name label stuck on the product s backside Find out the product code printed on the brand name lab...

Page 8: ...Symbol keys ENGLISH 8 4 Guide to installation 4 1 Product sizes and accessories 4 2 TFX01 side mounting brackets Guide to installation COD TFX01...

Page 9: ...side fasteners of chrome plated steel with M3 fixing screws and steel handle washers Direction of the luminous flux adjustable at 70 Installation with TFX01 side mounting brackets Hook the two side b...

Page 10: ...er Damaged or broken lamp When side mounting the lamp ensure to never completely loosen the M3 screws allowing for lamp rotation to avoid having the lamp fall down The side fasteners must be checked o...

Page 11: ...Wrong wiring may cause damages to the lamp All electrical connections have to be carried out by qualified electricians Please respect the polarity of connectors Always use the power cord supplied with...

Page 12: ...es A Coding connector female with pre assembled UL PVC Cable 4X0 75mmq Cross section PIN connection conductor 1 DC 24VDC brown 2 Not connected white 3 DC 0VDC blue 4 Not connected black Power cord DES...

Page 13: ...to replace the PCB LED if the lamp is properly installed and used following the instructions in this manual Please contact CCEA s Technical Support service or your Reseller in case the replacement of...

Page 14: ...ollowing different ways Any unauthorized repairs or attempts to repair the product Equipment operation under environmental conditions other than those specified in the user manual Liquid leakages insi...

Page 15: ...Please refer to the data printed on the label or engraved on the lamp Power supply 22 28 VDC Power input 6 12 18 24W see label IEC Class III Degree of protection IP67 compatible with NEMA type 12 LED...

Page 16: ...Symbol keys ENGLISH 16 14 Symbol keys CE Conformity marking Protection class III device Degree of protection IP67 IP67 WARNING Cancer and Reproductive Harm www P65Warnings ca gov...

Page 17: ...articular requirements part 4 Portable general purpose luminaries CEI EN 62031 LED modules for general lighting Safety specifications CEI EN 62384 DC or AC supplied electronic control gear for LED mod...

Reviews: