mdresult=<SP><hexadecimal
byte0><SP><hexadecimal
byte1>...<SP><hexadecimal byte63>
where <SP> is the SPACE symbol, and the byte value, byteN, indicates the
number of sub-zones (blocks of 32x32 pixels) with motion within zone N.
Note: the sub-zone size is fixed to 32x32 and cannot be changed.
Important: the user should keep in mind that the total number of zones is
always 64 (8 vertically and 8 horizontally). Therefore, if the zone size is
large, some zones may not correspond to the active pixel array. In that
case their motion detection value is not meaningful and should be ignored.
For example, for MP1 camera: if the image size is 1280x1024, then for
zone size 8x8 there are 5 by 4 active zones (3 zones after every 5 zones
must be ignored as well as all zones after zone 32). Example:
mdresult= 00 1A 01... means that in zone 0 motion was not detected,
in zone 1 there are 26 (32x32) sub-zones with motion, in zone 2
there is one sub-zone 1 with motion ….
Access Control
CBC (America) cameras support dual-level password-protected access control.
Camera authentication is compatible with RFC-2068 HTTP 1.1 and is supported
by all standard browsers and video surveillance software.
There are two types of users with the following reserved names:
a dmin ‒ has full access to all camera settings and the video.
viewer ‒ has viewing access to all current camera settings and the video.
Setting and removing the passwords is the privilege of the admin user, while the
viewer can only use the existing password, but not change it. Factory defaults
erase all current passwords for both the admin and the viewer. A newly
shipped camera has no password protection and allows full anonymous access
from the network. In case the admin password has not been set, the camera has
full anonymous access from the network, even if the viewer password has been
set.
Access control setup consists of three steps:
1.
Set a dmin password (using http commands or using the cameraʼs web
page, see below).
2.
Log-in using the admin password and set the viewer password.
3.
Communicate the viewer password to the users.