Micro-control as
Operation and Maintenance Manual for MC-3-series
Page 2 of 9
MAN-05-006
Rev.
1
Operation and Maintenance Manual MC-3-series
Document number
Page 1: ...e Manual MC 3 series Document number MAN 05 006 This page is not a part of the customer manual and shall not be distributed Revision 1 2 3 4 5 Date 2005 07 14 Written by AB Checked by JL Approved by File name G 05 MAN 05 006 01 Operation and Maintenance Manual for MC 3 series Revision history Rev Changes 1 First revision 2 3 4 ...
Page 2: ...Micro control as Operation and Maintenance Manual for MC 3 series Page 2 of 9 MAN 05 006 Rev 1 Operation and Maintenance Manual MC 3 series Document number MAN 05 006 ...
Page 3: ...minal 5 2 1 1 Operating the terminal 5 2 1 2 Maintenance 5 2 1 3 Display Codes 5 2 1 4 Physical data 6 2 2 Battery Charger and Batteries 5 2 2 1 Changing the battery 6 2 2 2 Battery Charger Installation and Use 6 2 2 3 Disposing of the batteries 6 2 3 Base unit 6 2 3 1 Installation 6 2 3 2 Maintenance 6 2 3 3 Display Codes 6 2 3 4 Physical data 6 2 4 Carrying Belt Strap 6 2 5 Antenna 6 2 5 1 Insta...
Page 4: ...unctions are built into each A unique serial number for each system means one system cannot operate another A check sum in the data transmission ensures that the system only recognises valid data Double monitoring of joysticks An activity check during start up prevents the terminal from starting if a switch or joystick is faulty or if a security critical function is active Self checks and continuo...
Page 5: ...hat are described in this chapter are common for all MC 3 series deliveries Micro control can supply manuals for specific machines if requested to do so 2 1 1 Operating the terminal Check that a fully charged battery is in the terminal Pull twist the Emergency Stop pushbutton out and turn the terminal ON Press the start pushbutton if fitted After a self test approx 1 second the terminal will estab...
Page 6: ...y Charger Installation and Use Install the battery charger in a clean and dry environment with temperature 10 C 40 C Connect the charger to the correct supply voltage Insert the battery to be charged Wait to see the indication that charging is normal Leave the battery in the charger until it is required for use Use only the battery charger supplied with the system or a replacement from Micro contr...
Page 7: ...f the housing or some distance away with an extension cable supplied by Micro control as 2 5 1 Installation The best location for the antenna is somewhere in free space If possible mount it so that you have a free line of sight to the operators position Do not mount the antenna inside a metal enclosure and take care that the antenna will not be damaged by moving machinery 3 Warranty All the delive...
Page 8: ...ition or a switch is in ON position Set all switches joysticks to OFF position and or neutral position 3 flashes with a stop Radio fault Change Replace the Radio module 4 flashes with a stop Shutdown because of low battery voltage Replace the battery with a fully charged one 5 flashes with a stop Keyboard fault The terminal is not able to read switches joysticks etc There is a fault at the input m...
Page 9: ...yed is an integer between 1 and 13 Is displayed only when the terminal is in programming mode None A 00 No analog channel is activated Is only displayed when the terminal is in programming mode Activate the analog channel that you wish to program E001 Processor fault Indicates a processor module fault and or a processor fault Ensure that the processor module BOOT jumper is not turned on Replace th...