background image

TORQUE CHART

Pump Item

Torque

Pump Model

Thread

Tool Size [P/N]

in. lbs.

ft. lbs.

Nm

Plunger Retainer

1851, 1861

M6

M12 Hex

55

4.6

6.2

Valve Block  Manifold Screws

1851, 1861

M12

M10 Allen [33047]

355

30.0

40

Discharge Manifold Nuts

1851, 1861

M10

M17 Hex [25083]

250

21.0

28

Rear Cover/Bearing Cover Screws

1851, 1861

M6

M10 Hex [25082]

50

4.0

5.4

Connecting Rod Screws

1851, 1861

M8

M13 Hex [25324]

216

18

24

Bubble Oil Gauge

1851, 1861

M28 Oil Gauge Tool [44050]

45

3.6

5.0

PREVENTATIVE MAINTENANCE CHECK-LIST

Check

Daily Weekly 50 hrs. 500 hrs.* 1500 hrs.** 3000 hrs.**

Clean Filters

x

Oil Level/Quality

x

Oil Leaks

x

Water Leaks

x

Belts, Pulley

x

Plumbing

x

Initial Oil Change

x

Oil Change

x

Seal Change

x

Valve Change

x

Accessories

x

TECHNICAL BULLETIN REFERENCE CHART

No.

Subject

Models

002

Inlet Pressure VS Liquid Temperature

All Models

003

Power Unit Drive Packages

3PFR - 68PFR, 10FR - 60FR

024

Lubrication of Lo-Pressure Seals

All Models

035

Servicing Crankcase Section

7PFR - 60PFR

036

Cylinder and Plunger Reference Chart

All Models

043

LPS and HPS Servicing

All Plunger Models

053

Liquid Gasket

All Plunger NAB-S.S. Models

064

By-Pass Hose Sizing

All Unloaders/Regulators

074

Torque Chart

Piston and Plunger Pumps

077

Oil Drain Kit

All Models (except 2SF/4SF)

083

Winterizing a Pump

All Models

089

Machined Valves

15PFR and 18PFR

* If other than CAT PUMPS special multi-viscosity ISO68 oil is used,

change cycle should be every 300 hours.

** Each system’s maintenance cycle will be exclusive. If system per-

formance decreases, check immediately. If no wear at 1500 hours,
check again at 2000 hours and each 500 hours until wear is ob-
served. Valves typically require changing every other seal change.

Duty cycle, temperature, quality of pumped liquid and inlet feed
conditions all effect the life of pump wear parts and service cycle.

** Remember to service the regulator/unloader at each seal servicing

and check all system accessories and connections before resuming
operation.

Refer to video for additional assistance.

INLET CONDITION CHECK-LIST

Review Before Start-Up

Inadequate inlet conditions can cause serious malfunctions in the best designed
pump. Surprisingly, the simplest of things can cause the most severe problems or go
unnoticed to the unfamiliar or untrained eye. REVIEW THIS CHECK-LIST BEFORE
OPERATION OF ANY SYSTEM. Remember, no two systems are alike, so there can
be no ONE best way to set-up a system. All factors must be carefully considered.

INLET SUPPLY should exceed the maximum flow being delivered by the pump to
assure proper performance.

Open inlet shut-off valve and turn on water supply to avoid starving pump.
DO NOT RUN PUMP DRY.

Temperatures above 130°F are permissible. Add 1/2 PSI inlet pressure per each
degree F over 130°F. Elastomer or RPM changes may be required. See Tech
Bulletin 002 or call CAT PUMPS for recommendations.

Avoid closed loop systems especially with high temperature, ultra-high pressure
or large volumes. Conditions vary with regulating/unloader valve.

Low vapor pressure liquids, such as solvents, require a booster pump and C. A.T.
to maintain adequate inlet supply.

Higher viscosity liquids require a positive head and a C. A.T. to assure adequate
inlet supply.

Higher temperature liquids tend to vaporize and require positive heads and
C. A.T. to assure adequate inlet supply.

When using an inlet supply reservoir, size it to provide adequate liquid to accom-
modate the maximum output of the pump, generally a minimum of 6-10 times the
GPM (however, a combination of system factors can change this requirement);
provide adequate baffling in the tank to eliminate air bubbles and turbulence; 
install diffusers on all return lines to the tank.

INLET LINE SIZE should be adequate to avoid starving the pump.

Line size must be a minimum of one size larger than the pump inlet fitting. Avoid
tees, 90 degree elbows or valves in the inlet line of the pump to reduce the risk of
flow restriction and cavitation.

The line MUST be a FLEXIBLE hose, NOT a rigid pipe, and reinforced on SUCTION
systems to avoid collapsing.

The simpler the inlet plumbing the less the potential for problems. Keep the
length to a minimum, the number of elbows and joints to a minimum (ideally no
elbows) and the inlet accessories to a minimum.

Use pipe sealant to assure air-tight, positive sealing pipe joints.

INLET PRESSURE should fall within the specifications of the pump.

Acceleration loss of liquids may be increased by high RPM, high temperatures,
low vapor pressures or high viscosity and may require pressurized inlet and
C. A.T. to maintain adequate inlet supply. DO NOT USE C.A.T. WITH SUCTION
INLET.

Optimum pump performance is obtained with +20 PSI (1.4 BAR) inlet pressure
and a C. A.T. for certain applications. With adequate inlet plumbing, most pumps
will perform with flooded suction. Maximum inlet pressure is 60 PSI (4 BAR).

After prolonged storage, pump should be rotated by hand and purged of air to 
facilitate priming. Disconnect the discharge port and allow liquid to pass through
pump and measure flow.

“K” versions are suitable for high inlet pressures. Consult CAT PUMPS.

INLET ACCESSORIES are designed to protect against over pressurization, control
inlet flow, contamination or temperature and provide ease of servicing.

A shut-off valve is recommended to facilitate maintenance.

Installation of a C. A.T. is essential in applications with stressful conditions such
as high temperatures, booster pump feed or long inlet lines. Do not use C. A.T.
with negative inlet pressure.

A stand pipe can be used in some applications to help maintain a positive head
at the pump inlet line.

Inspect and clean inlet filters on a regular schedule to avoid flow restriction.

A pressure transducer is necessary to accurately read inlet pressure. Short
term, intermittent cavitation will not register on a standard gauge.

All accessories should be sized to avoid restricting the inlet flow.

All accessories should be compatible with the solution being pumped to prevent
premature failure or malfunction.

Optional inlet protection can be achieved by installing a pressure cut off switch
between the inlet filter and the pump to shut off pump when there is no positive
inlet pressure.

“K” versions are suitable for high temperatures and containment of harmful 
liquids. Consult CAT PUMPS for optional flushing and cooling accessory.

BY-PASS TO INLET Care should be exercised when deciding the method of by-pass
from control valves.

It is recommended the by-pass be directed to a baffled reservoir tank, with at
least one baffle between the by-pass line and the inlet line to the pump. 

Although not recommended, by-pass liquid may be returned to the inlet line of the
pump if the system is properly designed to protect your pump. When a pulsation
dampener is used, a PRESSURE REDUCING VALVE must be installed on the
inlet line (BETWEEN THE BY-PASS CONNECTION AND THE INLET TO THE
PUMP) to avoid excessive pressure to the inlet of the pump. It is also recommend-
ed that a THERMO VALVE be used in the by-pass line to monitor the temperature
build-up in the by-pass loop to avoid premature seal failure.

A reinforced, flexible, low pressure hose rated up to 300 PSI should be used for
routing by-pass back to the pump inlet.

Caution should be exercised not to undersize the by-pass hose diameter and
length. Refer to Technical Bulletin 064 for additional information on the size and
length of the by-pass line.

Check the pressure in the by-pass line to avoid over pressurizing the inlet.

The by-pass line should be connected to the pump inlet line at a gentle angle of
45° or less and no closer than 10 times the pump inlet port diameter e.g. 1-1/2"
port size = 15" distance from pump inlet port.

Summary of Contents for 1851

Page 1: ...hich would be read at the discharge manifold of the pump NOT AT THE GUN OR NOZZLE Use PTFE thread tape or pipe thread sealant sparingly to connect accessories or plumbing E xercise ca ution not to wrap tape beyond the last threa d to avoid tape from becoming lodged in the pump or accessories This condition will cause a malfunction of the pump or system PRESSURE REGULATION All systems require both ...

Page 2: ...s 2 and 3 found under Disassembly for Discharge Valves 2 Using an allen wrench remove the Hex Socket Head Screws HSH from the VBM 3 Insert two M8x114 metric threaded bolts into the right and left servicing holes on the VBM face Thread in bolt until it makes contact with Inlet Manifold Continue threading until manifolds begin to separate Support underside of VBM to avoid possi ble damage to ceramic...

Page 3: ...nto valve chamber of Discharge Manifold with Spring Retainer facing down until completely seated 14 Support the VBM from the under side and slide manifold over Manifold Studs Apply anti seize to HSH screw threads and thread in hand tight Torque in sequence to specifications in torque chart 15 Support the Discharge Manifold from the under side and slide manifold over the Manifold Studs Install Flat...

Page 4: ...ilicone base lubricant NOTE For standard installation apply a small amount of oil to the outside edge of the LPS HPS VP MA FA and O Rings for ease of installation and to avoid damage Models 1861 1861K 1 Examine Lo Pressure Seals for wear to the internal ridges outer surfaces or for broken springs and replace as needed 2 Examine LPS Adapters for scale build up or wear and O Rings for cuts or deteri...

Page 5: ... 8 Examine Gaskets O Rings and Back up Rings for cuts or wear and replace as needed 9 Examine Plunger Retainers for wear or damaged threads and replace as needed Plunger arrangement 10 Install Gaskets first then O Rings and Back up Rings onto Plunger Retainers NOTE Lubricate O Rings and Back up Rings for ease in installation and to reduce possible damage 11 Apply Loctite 242 to exposed threaded en...

Page 6: ...Line size must be a minimum of one size larger than the pump inlet fitting Avoid tees 90 degree elbows or valves in the inlet line of the pump to reduce the risk of flow restriction and cavitation The line MUST be a FLEXIBLE hose NOT a rigid pipe and reinforced on SUCTION systems to avoid collapsing The simpler the inlet plumbing the less the potential for problems Keep the length to a minimum the...

Page 7: ...34 10 4 6 220 52 16 7 1 8 300 80 25 10 2 10 450 120 38 14 3 15 900 250 80 30 7 20 1600 400 121 50 12 25 650 200 76 19 30 250 96 24 40 410 162 42 50 600 235 62 60 370 93 At a fixed flow rate with a given size hose the pressure drop across a given hose length will be directly proportional A 50 ft hose will exhibit one half the pressure drop of a 100 ft hose Above values shown are valid at all pressu...

Page 8: ...If low recharge or install a new dampener Foreign material trapped in inlet discharge valves Clean inlet discharge valves or install new valve kit Water leak Under the manifold Worn V Packings High Pressure or Lo Pressure Seals Install new seal kit Increase frequency of service Worn adapter o rings Install new o rings Into the crankcase Humid air condensing into water inside the crankcase Install ...

Reviews: