caso FastVac 4000
45
17.2 Cleaning
Outside of the unit
•
Wipe with a damp cloth or sponge and mild dish soap.
Inside of the unit
•
Wipe away any food or liquids with a paper towel.
Cleaning bags for reuse
•
Wash the bags in warm water with a mild dishwashing soap, then rinse them well
and allow them to dry completely before reusing
.
DANGER
► Bags used to store raw meats, fish or greasy foods should never be reused due to risk
of contamination.
18 Troubleshooting
The following table may help you narrow down and address minor malfunctions:
18.1 Safety notices
DANGER
► Only qualified electricians, who have been trained by the manufacturer may carry out
any repairs on electrical equipment.
► Improperly performed repairs may result in personal injury or damage to the device.
18.2 Troubleshooting table
Fault
Possible Cause
To Rectify
Device does not turn
on
Defective power cord
Send device to Customer Service
A complete vacuum is
not being created in
the bag.
The open end of the bag is
not completely inside the
vacuum chamber
Position the bag correctly
The bag is defective
Select another bag
There is residue on the
welding and the seal
Clean the welding / seals and
retry once they are dry
The bag is not being
sealed correctly
The sealing bar is
overheating so that the bag
melts
Open the cover on the unit and
let it cool down for a few minutes.
Please use only specified bags