– 10 –
SE-S400/SE-S800/PCR-T500/PCR-T520/SE-C450
SE-S3000/SE-S900/PCR-T2300/PCR-T2400/SE-C3500
B-2. Disengage the hooks and remove the CASE/UPPER.
NOTE:
It is connected by the cable. Remove the CASE/UPPER carefully.
NOTES ON ASSEMBLY
Run the FFC for the Customer Display
through the hole of the case.
Hooks
Hooks
Hooks
B-3. Disconnect the cable (Main Display), FFC (Customer Display), and FPC (Key).
FFC (Customer Display)
FPC (Key)
Cable (Main Display)