![Casio PCR-T2300 Service Manual Download Page 35](http://html1.mh-extra.com/html/casio/pcr-t2300/pcr-t2300_service-manual_2568579035.webp)
– 33 –
SE-S400/SE-S800/PCR-T500/PCR-T520/SE-C450
SE-S3000/SE-S900/PCR-T2300/PCR-T2400/SE-C3500
[12] Time & Date Setting/Time & Date Display
[Function]
Allows you to check or change the time (hour, minutes, seconds) and date (year, month, day) that
are currently set.
[12-1] Time & Date Setting
[Operation]
<Time setting>
Command : h h m m s s
0
0
7
0
k
hh
Hour
mm
Minutes
ss
Seconds
• The new settings are printed out when the it is complete.
<Date setting>
Command : y y m m d d
0
1
7
0
k
yy
Year
mm
Month
dd
Day
• The new settings are printed out when the it is complete.
[12-2] Time & Date Display
Command :
7
0
or
1
7
0
k
• To end the display, press the
C
key.
[Display of the Result]
YY/MM/DD HH:MM SS
[13] Drawer Open Test
[Function]
Tests whether drawers operate correctly. The drawer sensor checks every two seconds while
the drawer open test is performed in
fi
nite times. Only when the drawer is closed, the drawer is
reopened.
[Operation]
Command : n
0
9
1
k
n: Number of times to run
0
Once (Can be omitted)
1 ~ 9
In
fi
nite loop (To forcibly terminate the test, press the
C
key.)
[Display of the Result]
DRW OK
[Printout of the Result]
DRW 91
DRW OK
END 91