– 11 –
SE-S400/SE-S800/PCR-T500/PCR-T520/SE-C450
SE-S3000/SE-S900/PCR-T2300/PCR-T2400/SE-C3500
C. PCB ASSY/E292-COM
C-1. Remove the COVER/CONNECTOR.
C-2. Undo four lock screws.
C-3. Disconnect the CABLE/FFC JOINER.
C-4. Remove the PCB ASSY/E292-COM.
COVER/CONNECTOR
Lock screws (4)
CABLE/FFC JOINER
PCB ASSY/E292-COM
D. PRINTER
NOTE:
This procedure is applicable for a single printer. Repeat the steps for two-printer models.
D-1. Undo two screws.
D-2. Disconnect one FPC.
D-3. Remove the PRINTER.
PRINTERs
FPC
FPC
Screws (S2)
NOTE:
When replacing the PRINTER with a new part, remove the roller from the new PRINTER and
replace it with the roller for the PLATEN ARM.
Roller