Xiamen Cashino Technology Co.,Ltd
A2L User Manual
37
Whatever the input data length is 11 or 12,the check bit is automatically
inserted or corrected
Initial character,central split character,and terminator are inserted
automatically
When print UPCE
(
m = 1 or 66
)
,Please pay attention as following:
The system character (NSC) 0 will be inserted automatically when
data
length is 6
The first system character (NSC) d1 must be 0 when the data length
is 7,8,11 and 12.
Whatever the data length is 6,7,8,11 and 12,the check bit inserted or
corrected automatically
Whatever the input data length is 6,7,8,11,and 12,the barcode
readable character(HRI) just show 6 as data,but excluded system
character (NSC) and check code;
The transition relation between transmission and printing data as
below:
When d6 is 1~9,be sure d7,d8,d9,d10 are 0,and d11 is 5~9
Initial character,terminator automatically inserted
When print EAN13(m = 2 or 67),Please pay attention as following:
Whatever the input data length is 12 or 13,check bit is automatically
inserted or corrected
Initial character,central split character and terminator inserted
automatically
When print EAN8(m = 3 or 68),please pay attention as following:
Whatever input data length is 7 or 8,the check bit is automatically
inserted or corrected
Initial character,central split character and terminator inserted
automatically
When print CODE39(m = 4 or 69),please pay attention as following:
When d1 or dn are not Initial character/terminator ”*”, encoder is
automatically inserted ”*”