background image

9

M

alibu

 S

tar

®

Please refer to this guide before requesting service or contacting your dealer for assistance.

TROUBLESHOOTING TIPS

PROBLEM 

POSSIBLE REMEDIES 

Fan will not start

 

•  Check the main circuit fuses, circuit breakers, and wall switch position. Check all 

wire connections. Make sure the power is turned off during this inspection.

Fan is noisy during operation

 

•  Check and tighten the light fixture retaining screws, glass shade screws, and/or 

lightbulb(s).

 

•  Tighten the blade to bladeholder screws.

 

•  Tighten the canopy screws and mounting plate assembly. 

 

•  Check and tighten blade holders to flywheel (or direct drive motor).

 

•  Make sure all screws in the motor housing are snug but not overly tight.

 

•  Check that the wire nuts inside the canopy and switch housing are not touching 

the metal parts or have fallen off the wire splices. Tighten or adjust as necessary.

Fan runs slowly in either direction

 

•  Defective reverse switch, defective capacitor, or open motor winding. Replace

if rotation is started by hand; will not

 

  reverse switch assembly, replace PCB assembly, or replace motor unit.

reverse

Fan will not  operate at proper speeds

 

•  Defective three-speed pull-chain switch assembly or defective capacitor. Replace

or will not operate at any speed

 

  three-speed pull-chain switch assembly or replace PCB assembly.

Fan wobbles or shakes excessively

 

•  Check that all blades are set to exactly the same angle by repeating the "Blade 

Angle Adjustment" instructions on page 7.

 

•  Check that all blades are installed correctly in the blade holder assembly so that 

their leading edge is facing the correct direction. See "Blade Orientation" section, 

Step 10, on page 7. 

All blades flap

 

•  Blade orientation has material as leading edge. Orient blades correctly, then set 

blade angle by repeating Steps 10 through 12 on page 7 starting with "Blade 

Orientation."

One blade flaps

 

•  Blade wire tension is incorrect. Return blade set to factory for service 

refurbishment and repair.

 

•  Blade material is torn. Return blade set to factory for service refurbishment and 

repair.

No airflow from fan 

•  Blade angle is set flat. Orient blades correctly.

 

•  Blade angle is set too low. Orient blades correctly.

 

•  Blade angle is set for upward airflow. Orient blades correctly.

Summary of Contents for Malibu Star

Page 1: ...81 Wall Control for Fan and Lights 8 W 80 or W 81 Wall Control Operation 8 TROUBLESHOOTING TIPS 9 CARE RECOMMENDATIONS 10 PRODUCT SPECIFICATIONS 10 READ AND SAVETHESE INSTRUCTIONS SAFETY FIRST Safety...

Page 2: ...wiring codes you should use a qualified electrician To avoid overheating and possible damage to other equipment do not install control to a receptacle fluorescent light fixture motor operated applian...

Page 3: ...imum SUGGESTED EXTENSION POLE LENGTHS When to Use Extension Poles For best performance and appearance an extension pole should be used with your Casablanca fan when installing on high cathedral ceilin...

Page 4: ...packaging material be certain that all parts have been removed PERMA LOCK HARDWARE Allen Set Screw 1 4 20 x 1 4 pre installed 3mm Allen Wrench Downrod Ball Assembly Motor Wires Ground Wire Downrod Bal...

Page 5: ...dware included with the outlet box Tighten the screws firmly by hand only being careful not to bend the bracket by over tightening Ceiling Fan Approved Outlet Box Ceiling Wiring Crossbar Mounting Brac...

Page 6: ...CK power wire from fan to RED wire from W 80 in ceiling outlet box Secure with wire nut Cap BLUE D 1 Option wire with wire nut Step 6b W 80 or W 81 Wiring Connections WITH light fixture GREEN leads fr...

Page 7: ...blade with the proper orientation as described in previous Step 9 NOTE Before securing the fan blade adjust the pitch or angle of the blade for either upward or downward air flow as described below in...

Page 8: ...OPERATION The W 80 or W 81 wall control provides separate control of fan and light with two separate knobs from a convenient wall location The W 80 or W 81 is designed to replace a standard wall swit...

Page 9: ...ot reverse switch assembly replace PCB assembly or replace motor unit reverse Fan will not operate at proper speeds Defective three speed pull chain switch assembly or defective capacitor Replace or w...

Page 10: ...ed radio TV technician for help NOTE Any changes or modifications to the transmitter or receiver not expressly approved by Casablanca Fan Company may void one s authority to operate this remote contro...

Reviews: