15                                                                  8/31/2015

 

3.

 

Error Messages & Solution 

Error 

Message 

on Display 

Description 

Solution 

"Err 0"

 

The "Err 0" occurs when scale is not stable.

 

Remove unstable facts. 

"Err 1"

 

The  "Err  1"  occurs  when  a  current  zero  point 

has shifted from the last span calibration.

 

Please call your CAS 

dealer. 

"Err 2"

 

The "Err 2" is not a real error. Only it prompts 

return CAL switch to the normal position.

 

Please call your CAS 

dealer. 

"Err 3"

 

The "Err 3" is an overload error.

 

Please remove the 

weight. 

"Err 4"

 

The "Err 4" is leakage of payment.

 

Scale needs more 

payment. 

"Err 5"

 

The "Err 5" means there is already tare.

 

Remove the tare. 

"Err 6"

 

The  "Err  6"  means  total  price  summation  is 

over. 

 

Please change unit price 

or remove some weight. 

"Err 7"

 

The "Err 7" means total price is over. 

 

Please change unit price 

or remove some weight. 

"Err 8"

 

The "Err 8" means Euro rating price is over.

 

Please change unit price 

or change euro rate. 

“Err 11” 

The  "Err  11"  means  a  writing  error  of  the 

internal  nonvolatile  memory.  To  recognize  this 

error, be sure to check the voltage on the circuit 

and do calibration procedures. 

If it still has "Err 11", 

replace the digital module.

 

“Err 12” 

The  "Err 12" warns that  the  scale has  lost the 

parameters for weighing regulations or has lost 

the factors for a digital span calculation. 

Enter each condition codes 

again (?).   

Please try a span 

calibration again if still not 

fixed. 

“Err 13” 

The "Err 13" means the soft key code is broken. 

Please try to find out which 

key lost soft key code and 

then input this code again. 

“Err 14” 

The  "Err  14"  means  calibration  range  is  not 

correct. 

Please call your CAS 

dealer.

 

“Err 15” 

The "Err 15" means 1/2 or 1/4 unit price is over. 

Please change unit price

 

 

 

 

 

Summary of Contents for PR-T Series

Page 1: ...PR T Service Manual 1 8 31 2015 PR T SERVICE MANUAL...

Page 2: ...1 6 Input Function Key Code C 6 2 1 7 Percent Calibration C 7 2 1 8 Battery Calibration C 8 3 Error Messages Solution 15 4 The Schematics and Diagram 16 4 1 System Block Diagram 16 4 2 Circuit Diagra...

Page 3: ...ion Make sure that you plug your scale into the proper power outlet Place the scale on a flat and stable surface Plug into a power outlet 30 minutes before operations Keep the scale away from strong E...

Page 4: ...ce Symbols Power Battery Zero Stable Tare Discount Caps Sum Interface RS232 Keys Number 0 9 Direct PLU 01 30 ZERO TARE Feed Discount Menu PLU call Total Add Void Clear Multiply Print Function Direct P...

Page 5: ...PR T Service Manual 5 8 31 2015 1 4 Dimension...

Page 6: ...go to program mode To call up a PLU with numeric key To input non weighed item SHIFT To select alternate key functions To show subtotal total payment sum Direct PLU keys Alphabet Key A Z key To chang...

Page 7: ...PR T Service Manual 7 8 31 2015 1 6 SealingMethod...

Page 8: ...Setting TARE key MODE Function CAL 1 Display normalized AD CAL 2 Display Keypad infomation CAL 3 Weight Setting Mode UnLoad TARE MIDD TARE after loading for mid capacity weight FULL TARE after loading...

Page 9: ...d then it displays span message 7 Load full weight on the platform 8 Press TARE key and then it displays middn message 9 Load middle weight ex 1 3 full capacity on the platform 10 Press TARE key and t...

Page 10: ...6 Use Preset tare 0 Don t use 1 Use BIT5 Use Back light 0 Don t use 1 Use BIT4 Use Head message 0 Don t use 1 Use BIT3 Use gram 0 Don t clear 1 Clear BIT2 Use oz 0 Don t clear 1 Clear BIT1 Use lb 0 Do...

Page 11: ...message 2 Press ZERO to display CAL 7 3 Press TARE key and then it displays per 0 message Select the percent value using the numeric key You can choose 10 90 percent 4 Press TARE key and then it displ...

Page 12: ...e will be shown 2 1 6 Calibration factor Setting C 10 1 Pressing and holding Calibration Switch press POWER key 2 After CAL message blinks three times and shows the version of scale it displays CAL 1...

Page 13: ...a division by using ZERO key 14 Press TARE key and then dual message blinks 1 will be shown The third digit 1 will blink It means a dual interval is disable 0 disable 1 enable 15 Input a dual interva...

Page 14: ...PR T Service Manual 14 8 31 2015...

Page 15: ...eans total price is over Please change unit price or remove some weight Err 8 The Err 8 means Euro rating price is over Please change unit price or change euro rate Err 11 The Err 11 means a writing e...

Page 16: ...ervice Manual 16 8 31 2015 4 The Schematics and Diagram 4 1 System Block Diagram PR T MAIN BOARD LOAD CELL KEY AD CONVERTER MCU LED DRIVER DISPLAY BOARD POWER110 220V 50 60HZ RECHARGE PB BAT PRINTER M...

Page 17: ...PR T Service Manual 17 8 31 2015 4 2 Circuit Diagram 4 2 1 Main...

Page 18: ...PR T Service Manual 18 8 31 2015 4 2 2 Power Part...

Page 19: ...PR T Service Manual 19 8 31 2015 4 2 3 Key Part...

Page 20: ...PR T Service Manual 20 8 31 2015 4 2 4 Display Part...

Page 21: ...PR T Service Manual 21 8 31 2015 5 Exploded View 5 1 BODY...

Page 22: ...PR T Service Manual 22 8 31 2015 5 2 Load Cell drawing...

Page 23: ...PR T Service Manual 23 8 31 2015 6 Part 6 1 Part Location Main PCB Top...

Page 24: ...PR T Service Manual 24 8 31 2015 6 1 1 Main PCB Bottom...

Page 25: ...PR T Service Manual 25 8 31 2015 6 1 2 Front Display PCB Top...

Page 26: ...PR T Service Manual 26 8 31 2015 6 1 3 Front Display PCB Bottom...

Page 27: ...PR T Service Manual 27 8 31 2015 6 1 4 Rear Display PCB Top 6 1 5 Rear Display PCB Bottom...

Page 28: ...PR T Service Manual 28 8 31 2015 6 1 6 Pole Display PCB Top...

Page 29: ...PR T Service Manual 29 8 31 2015 6 1 7 Pole Display PCB Bottom...

Page 30: ...30 8 31 2015 6 2 Part Order List A Electronins Parts No Order No Part Name Image Remark 1 6R00 PR0 1000 0 MAIN PCB 2 6R10 PR0 1000 0 FRONT DISPLAY PCB 3 6R10 PR0 1001 0 REAR DISPLAY PCB 4 6R10 PR0 100...

Page 31: ...T Service Manual 31 8 31 2015 5 7520 P00 7000 0 BATTERY 102 46 3 4 6 3 4V 4Ah PB 6 7840 W00 3110 0 BATTERY WIRE 3P 110 240MM 7 7520 PPR 0220 0 TRANSFO RMER 220V 7V 800mA 8 7620 S00 0100 0 FUSE 250V 10...

Page 32: ...PR T Service Manual 32 8 31 2015 9 7860 GND 0250 C GROUND WIRE 1P 250mm GREEN 10 7860 GND 0080 0 GROUND WIRE 1P 80mm GREEN 11 7834W0010200 SHIELD WIRE POLE WIRE P type Only...

Page 33: ...1000 0 BODY 340 335 150 ABS GLASS 1 2 2022 A00 0005 0 WATER LEVEL GAGE 14 5 8 CHINA 1 3 2631 PR0 0001 0 BATTERY CUSHION 85 45 25 8 1 4 1000 A00 1000 0 BRACKET_SEALING 36 20 1 0 1 5 2000 A00 1001 0 BAT...

Page 34: ...008 A00 0001 B FOOT M6 20 RUBBER 4 11 1502 A00 0308 0 MACHINE SCREW M3 8 2 12 1510 A00 0412 0 TAPPING SCREW PH M4 12 10 13 1532 A00 0625 0 BOLT WRENCH ST M6 25 STOPPER 1 14 1510 A00 0412 0 TAPPING SCR...

Page 35: ...PR T Service Manual 35 8 31 2015 18 1551 A00 0630 0 WASHER SPR M6 6 3 2 19 1502 A00 0308 0 SCREW MACHINE PH M3 8 CHINA 1 20 1502 A00 0406 0 SCREW MACHINE PH M4 6 1...

Page 36: ...LT WRENCH ST M4 25 4 3 1540A0004000 NUT HEX M4 3 4 4 5519PR000300 LOADCELL 130 30 22 1 5 1530MPZ06200 BOLT WRENCH M6 20 2 6 1551MPZ06000 WASHER SPR M6 6 3 2 B 3 TRAY BRACKET ASS Y B P TYPE NO IMAGE CO...

Page 37: ...OVER 195 85 92 7 0 5 1 3 3050PRB06332 REAR DISPLAY COVER 263 4 42 5 0 5 1 4 3050PRB15332 REAR DISPLAY COVER 263 4 42 5 0 5 1 5 3050PRB30332 REAR DISPLAY COVER 263 4 42 5 0 5 1 6 2010A0000260 WATER LEV...

Page 38: ...10 CASE 340 335 150 ABS 1 2 3050PR000331 PR PLUS FRONT DUMP 195 85 92 7 0 5 1 3 2050PRB00330 CUST_DISP 263 4 42 5 0 5 1 4 2010A0000260 WATER LEVEL GAGE COVER 18 5 0 5t 1 5 3100PR000331 MEMBERSWITCH KE...

Page 39: ...TY 1 2000PR011180 DISPLAY CASE 194 136 18 5 ABS 2 2 3050PRR00331 DISPLAY COVER POLE 135 111 25 1 0 2 3 1150PR011220 PIPE 27 2 270 AL 1 4 2001A0000420 DISPLAY NUT 43 35 ABS 1 5 2000PR011380 POLE_BASE3_...