31
Serial Communication COM2 Function (USB Option)
F32
Function
Set COM2 Baud Rate
Display Meaning
F32 0
600 bps
F32 1
1200 bps
F32 2
2400 bps
F32 3
4800 bps
F32 4
9600 bps
F32 5
19200 bps
F32 6
38400 bps
F32 7
57600 bps
Setting range
(0 ~ 8)
F32 8
115200 bps
F33
Function
Set COM2 - Usage
Display Meaning
F33 0
Connect to a printer
Setting range
(0 ~ 1)
F33 1
Connect to a computer or auxiliary display
* If F29: 0 and F33 : 0, "ERR-Set" is displayed with no print.
* COM1 and COM2 cannot be used together as the printer function.
F34
Function
Set COM2 - Output Format
Display Meaning
F34 0
22 bytes for CA
F34 1
10 bytes for CA
Setting range
(0 ~ 2)
F34 2
18 bytes for AND
F35
Function
Set COM2 - Output Mode
Display Meaning
F35 0
No data out
F35 1
Transmission for both the stable and instable time (stream mode)
F35 2
One time transmission after the weight is stabilized.
F35 3
Transmission only if data is requested.
* Data request signal: device ID (F26) _ 1 byte communication
(Data on request: 1= 0x01, 10 = 0x0A)
Setting range
(0 ~ 4)
F31 4
Response to the data request - Command Mode
Set the value of F35 to '1' or more if the print mode is used.