17
CAL 1
(CAL 1 automatically starts.)
Function: Setting Maximum Value
Range of set value: 1 ~ 99,999
Used key
Display
Descriptions
C= 10000
Max. value = 10000kg
:Save and
next Menu navigation
: Set value change
: Changing places
C= 10
Max. value = 10kg
Note 1. It means the maximum weight value to be weighed by the scale.
CAL 2
Function: Minimum division and decimal position setting
Range of set value: 0.001 ~50
Used key
Display
Descriptions
d= 0.001
Minimum division 0.001 kg
d= 0.002
Minimum division 0.01 kg
d= 0.005
Minimum division 0.1 kg
d= 0.01
Minimum division 1 kg
:Save and
next Menu navigation
: Set value change
d= 0.1
Minimum division 10 kg
Note 1. The minimum division means the value of a division.
Note 2. Set the external resolution within 1/30,000 as the value by dividing the maximum weight by the minimum
division.
If the external resolution is
1/30,000 or more, Err 21 is shown.
Note 3. The position of a decimal point is decided by the position of a decimal point for the minimum division set
in CAL2.
Note 4. If the minimum division is set to any value out of 1, 2 and 5 unit, "ERR DIV" is shown.
Summary of Contents for PDI Series
Page 1: ...2 ㅋ ...
Page 3: ...4 ...
Page 4: ...5 ...
Page 10: ...11 2 Specifications in Appearance 2 1 External Dimension PDI ...
Page 12: ...13 2 3 Rear Panel Descriptions ...
Page 41: ...42 MEMO ...
Page 42: ...43 MEMO ...
Page 43: ...44 MEMO ...
Page 44: ...45 ...