Line Thermal Printer DEP-50
64
65
User’s Manual
m (1)
Barcode type
Length
Range of ‘d’
0
UPC-A
11
48 <= D
i
<= 57
1
UPC-E
11
48 <= D
i
<= 57
2
EAN13 (JAN13)
12
48 <= D
i
<= 57
3
EAN 8 (JAN8)
7
48 <= D
i
<= 57
4
CODE 39
-
48 <= D
i
<= 57, 65 <= D
i
<= 90,
32, 36, 37, 43, 45, 46, 47
5
ITF
-
48 <= D
i
<= 57
6
CODABAR (NW-7)
-
48 <= D
i
<= 57, 65 <= D
i
<= 68,
36, 43, 45, 46, 47, 58
7
CODE 93
-
1 <= D
i
<= 127
8
CODE 128
-
1 <= D
i
<= 127
9
PDF-417
-
1 <= D
i
<= 255
[DESCRIPTION OF BAR CODES]
UPC-A
This bar code, consisting of numerals only, has a fixed length of 12
column; a 11-columns number entered from the host or application
software plus a check column(12th column) automatically calculaed
inside the printer. If the 12th-column numeral is sent from the host,
the entire bar code will be printed as it is.
UPC-E
This bar code, consisting of numerals only, has a fixed length of 8
column; the first number system character is “0” stationary. A 12
column numeral entered from the host or application software is
compressed to 8 columns with a check column and printed. The
12th-column check column is automatically calculated inside the
printer and sent from the host, the entire bar code will be printed,
compressed to 8 columns.
JAN-13
This bar code, consisting of numerals only, has a fixed length of
(EAN)
13 column; a 12-column number entered from the host or application
software plus a check column(13th column) automat cally
calculated inside the printer. If the 13th-column numeral is sent from
he host, the entire bar code will be printed as it is.
JAN-8
This bar code, consisting of numerals only, has a fixed length of 8
(EAN)
column; a 7-column number entered from the host or application
software plus a check column(8th column) automatically calculated
inside the printer. If the 8th-column numeral is sent from the host,
the entire bar code will be printed as it is.
CODE39
This bar code, consisting of uppercase alphabets and numerals,
has a variable length of column. A start/stop code “*” is automatcally
added by the printer. Available characters include a space and “$,
%, +, -, · , /, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9,” and uppercase alphabets.
ITF
This bar code, consisting of numerals only, has a variable length of
even column. If an odd-column code is tranferred, nothing will be printed.
CODABAR
This bar code, consisting of alpha numerals, has a variable
(NW-7)
length of column. Available characters include “0, 1, 2, 3, 4, 5, 6, 7,
8, 9, A, B, C, D, $, +, -,., /, :.” A start/stop code is required; any one
of A, B, C, and D is used.
CODE 93
This barcode, consisting of alphanumeric and control characters, has
a variable length of columns. HRI characters for control characters
(00H - 1FH, and 7FH) are each printed as a combination of a “^”
character and an alphabetic character.
M (2)
Barcode type
Length
Range of ‘d’
65
UPC-A
11
48 <= D
i
<= 57
66
UPC-E
11
48 <= D
i
<= 57
67
EAN13 (JAN13)
12
48 <= D
i
<= 57
68
EAN 8 (JAN8)
7
48 <= D
i
<= 57
69
CODE 39
-
48 <= D
i
<= 57, 65 <= D
i
<= 90,
32, 36, 37, 43, 45, 46, 47
70
ITF
-
48 <= D
i
<= 57
71
CODABAR (NW-7)
-
48 <= D
i
<= 57, 65 <= D
i
<= 68,
36, 43, 45, 46, 47, 58
72
CODE 93
-
0 <= D
i
<= 127
73
CODE 128
-
0 <= D
i
<= 127
74
PDF-417
-
0 <= D
i
<= 255
[Caution]
•
When data being held in the print buffer, this command is ignored.
•
Regardless of the specified feed pitch, this command feeds the
paper that is required to print a barcode.
•
If the character code d cannot be printed in the respective barcode
system, the barcode so far will be printed, processing the
subsequent data as normal data.
•
When a barcode whose number of characters to be printed is fixed
has been selected, the number of characters
k
have to be always
made equal to the number of characters to be printed. (The barcode
is not printed when not matching.)
•
When the horizontal direction exceeds one line length, the barcode
is not printed.
[Default]
•
The initial value is not specified.