- 9 -
SET MODE
Moving method
If you press the * key for three seconds to normal operation state, after display
“SET” message for one second and then enter F-1 menu.
Available keys
NET/GROSS Key : Increase the set point.
TARE Key : Move to the next menu.
ENTER Key : Return to the normal operation at completion of setting.
Set menu (F1~F2)
F-1
Auto power OFF setting
F-2
RS-232C communication setting
F01
Auto power OFF setting
Auto power OFF function is used to spare the battery by means of power off when
this scale is not used.
Display
Description
F-1 0
Auto power OFF is not used.
F-1 1
Automatically power off when the weight is not changed or no
key is used for 5 min.
F02
RS-232C communication setting
Display
Description
F-2 0
No transmit.
F-2 1
Transmit at both stable and unstable weight.
F-2 2
Transmit at stable weight.
F-2 3
Transmit at data request. (Data request signal “D”)
Summary of Contents for BW-SERIES
Page 1: ... 1 BATTERY WEIGHING SCALE BW SERIES SERVICE MANUAL Revision 2005 5 9 ...
Page 10: ... 10 SCHEMATIC DIAGRAM ...
Page 11: ... 11 P C B DIAGRAM MAIN PCB BOTTOMSIDE TOP SIDE ...
Page 12: ... 12 DISPLAY PCB BOTTOM SIDE TOP SIDE ...
Page 13: ... 13 CONNECTION DIAGRAM ...
Page 20: ... 20 BODY ASS Y LOW CAPACITY CAPACITY 30kg 15kg 6kg SPACE mm 2 4 3 8 1 35 ...
Page 21: ... 21 SET C T BOX ASS Y LOW CAPACITY ...
Page 22: ... 22 BODY ASS Y HIGH CAPACITY ...