MODEL
MODULES
WATTS
VOLTS
AMPS
MC1W2H
2
400
120
3.3
MC1W3H
3
600
120
5.0
MC1W4H
4
800
120
6.7
MC1W5H
5
1000
120
8.3
MC2W1H
2
400
120
3.3
MC2W2H
4
800
120
6.7
MC2W3H
6
1200
120
10.0
MC3W1H
3
600
120
5.0
MC3W2H
6
1200
120
10.0
MC4W2H
8
1600
120
13.3
MC2W4H
8
1600
120
13.3
MC112S-2
1
300
120
2.5
MC112S-4
1
300
120
2.5
MC112S-6
1
300
120
2.5
ELECTRICAL SPECIFICATIONS
1. Check for proper voltage and circuit breaker size. Cabinet requires 120 volt, sin-
gle phase, 15 Amp circuit. Refer to serial tag on the cabinet for the electrical re-
quirements for your particular cabinet.
2. Ensure receptacle is correctly installed and operating safely. Requires grounded
NEMA 5-15R receptacle.
3. Position cabinet on table or counter top. Maintain 2” of clearance on each side to
allow for adequate cooling.
Location
For proper operation and maximum performance, locate the unit in an ambient air tem-
perature of less than 80
°
F (21
°
C).
Avoid areas near exhaust fans where there are active air movements.
For safe operation, locate the unit a reasonable distance from combustible walls and
materials.
To prevent injury and damage, locate the unit at a proper and safe working height. The
location should be level, clean of debris, and strong enough to support the weight of a
fully loaded unit.
Counter-top Mounting
To prevent electrical shock, be sure unit is unplugged from an electrical outlet. If unit
has been operated, allow unit to cool before installing. For safety reasons, counter-
top must be made of a non-combustible material, clean and free of debris.
MODEL
MODULES
WATTS
VOLTS
AMPS
MC212S-2
2
600
120
5.0
MC212S-4
2
600
120
5.0
MC212S-6
2
600
120
5.0
MC212S2-2DD
2
600
120
5.0
MC212S-2T
2
600
120
5.0
MC223S-2T
2
400
120
4.2
MC243S-2T
2
600
120
5.0
MC423S-2T
4
1000
120
8.3
MC213S-2T
2
400
120
3.3
MC213GS-2T
2
400
120
3.3
MC223GS-2T
4
500
120
4.2
MC212GS-2T
6
600
120
5.0
MC243GS-2T
8
600
120
5.0
MC423GS-2T
8
1000
120
8.3
The charts below give electrical specifications for the most popular models, but due to the nature of continuing change to the number of
configurations we manufacture, may not list your model. Refer to the serial tag on your cabinet for actual electrical specifications.
INSTALLATION AND START-UP
Sample serial tag
location of electrical specs
GROUND
PIN
NEMA 5-15P
PLUG
NEMA 5-15P
RECEPTACLE
Alternate electrical specifications outside the United States by
destination country; refer to serial tag on cabinet.