Code setting of wired controller
Difference between the Function of the Master Wired Controller and Slave Wired Controller
Function switches
DIP switch
On/Off station
Function
Default setting
Sw1
On
Slave wired controller
Off
Off
Master wired controller
Sw2
On
Ambient temp. display on
Off
Off
Ambient temp. display off
Sw3
On
Collect ambient temp. from PCB of indoor
Off
Off
Collect ambient temp. from wired of controller
Sw4
On
Non-volatile memory invalid
Off
Off
Non-volatile memory valid
Sw5
On
Old protocol
Off
Off
Selfadaption
Sw6
On
Reserve
Off
Off
Reserve
Sw7
On
Model with Up/Down and Left/Right swing
Off
Off
Model with Up/Down swing
Sw8
On
Fresh Air unit
Off
Off
General unit
Comparison
item
Master wired
controller
Slave wired controller
Function
All function
are available
1. ON/OFF, Mode, Fan Speed, Temp. Setting, Swing, Energy Saving,
Clock Function, Heat Reclaim Ventilation function, Mode Setting,
Screen Saving and Child Lock are available
2. Cancel the filter cleaning icon
3. Look up the detailed parameter and malfuction code
Electrical Wiring
21
Summary of Contents for XCT 7 40VD005-054S-7S -QEE
Page 8: ...Parts and Function 1 indoor unit air outlet port air inlet port air duct soft connection...
Page 31: ...The manufacturer reserves the right to change any product specifications without notice...
Page 58: ...Il produttore si riserva il diritto di modificare le specifiche del prodotto senza preavviso...
Page 62: ...Pi ces et fonctions Unit int rieure Sortie d air Entr e d air Gaine d air Raccord souple 1...
Page 85: ...Le fabricant se r serve le droit de modifier les sp cifications du produit sans pr avis...
Page 112: ...Der Hersteller beh lt sich das Recht vor Produktspezifikationen ohne Vorank ndigung zu ndern...