![Carrier WEATHERMAKER 48AJ020 Installation, Start-Up And Service Instructions Manual Download Page 18](http://html.mh-extra.com/html/carrier/weathermaker-48aj020/weathermaker-48aj020_installation-start-up-and-service-instructions-manual_2560307018.webp)
18
Fig.
16
—
B
a
s
e
Unit
Dim
e
ns
ions
—
4
8
E
W
,EY0
5
4
-0
6
8
NO
T
E
S:
1
.
W
e
ig
hts
in
cl
ude
e
c
ono
m
iz
e
r (
s
ta
nd
ar
d)
.
2.
Ce
nt
e
r of
G
ra
v
it
y.
3.
Do
no
t lo
cate
ad
ja
cen
t u
n
its wi
th
flu
e
disch
a
rge
fa
ci
ng
eco
n
o
m
iz
er
i
n
le
t.
Min
Cl
ea
ra
nc
e
s
to
be
:
Ad
jace
n
t Un
its:
1
5
′
-0
″
[4
57
2].
T
o
p
of U
n
it
s: N
o
Ov
e
rhan
g.
C
o
n
d
e
n
se
r Co
il: 4
′
-0
″
[1
21
9].
Econ
om
iz
e
r Si
de
:
6
′
-0
″
[1
82
9].
He
at Si
de
:
4
′
-0
″
[1
21
9].
Filte
r Acce
ss Side
:
1
5
′
-0
″
[4
57
2].
(
F
or
rem
o
v
a
l of
e
v
ap
o
rat
o
r c
o
il.
)
4.
F
o
r
s
m
a
lle
r s
e
rv
ic
e
a
n
d
op
erat
io
na
l c
lea
ra
nc
e
s
c
ont
act C
a
rr
ie
r Ap
pl
ic
at
io
n E
ngi
n
eeri
ng D
e
par
t-
men
t.
5
.
B
a
se
un
it
w
e
ig
hts
in
cl
ud
e o
u
tdoo
r ai
r h
o
o
d
s
an
d f
ilt
e
rs
(
ind
o
o
r
fa
n
mot
o
r is
no
t inc
lud
ed
).
A
d
d
in
doo
r
mot
o
r,
FIOPs a
nd a
ccessor
ies f
o
r
to
ta
l op
er
ati
n
g w
e
ig
ht.
6.
V
A
V
mot
o
r w
e
ig
ht
s
in
c
lud
e i
n
d
o
o
r mo
to
r,
V
F
D
,
co
mp
re
s
s
o
r e
lec
tr
ic
un
lo
ad
er
s
, V
F
D
tr
an
s
d
uc
e
r
an
d a
s
s
o
c
ia
ted
wir
ing
.
7
.
F
o
r si
de
-s
upp
ly
/r
etu
rn a
ppl
ic
a
ti
ons
, a si
ng
le
re
tur
n
an
d su
pp
ly
du
ctw
o
rk
co
nn
ecti
o
n
i
s
r
e
c-
o
m
me
nd
ed
f
o
r
c
o
v
e
rin
g
al
l th
re
e
re
tur
n
a
n
d
al
l
th
re
e s
u
p
p
ly
o
p
e
n
ing
s
. Th
e
en
ti
re
ar
ea
ar
ou
nd
th
e du
c
t
o
p
e
n
in
g
s
is
a
v
ail
a
b
le f
o
r a 1.
5
″
du
ct
fl
ang
e a
tta
chm
e
n
t
8.
Dime
n
si
on
s
in
a
re in
in
che
s
[mm
].
B
A
SE UNIT WEI
G
HTS
(Se
e
Note 6
) lbs
(k
g)
05
4
0
58
06
4
0
6
8
48
EW
D/
EY
D
6
8
4
5
(
3
1
0
5
)
70
95
(
321
8)
734
5
(3
33
2)
7
5
2
0
(
3
4
1
1
)
48
EW
E
7
0
8
5
(
3
2
1
4
)
73
35
(
332
7)
758
5
(3
44
1)
7
7
6
0
(
3
5
2
0
)
UNIT SI
ZE
C
E
NT
E
R
OF GRA
V
IT
Y
%
OF T
O
T
A
L W
E
IGHT
A
T
EA
CH
CORNER
Inc
h
es
Mil
lime
te
rs
AB
AB
1
2
3
4
48E
WD
/EYD
05
4
1
30.
9
4
6
.9
332
5
1
1
9
2
2
2
.4
19.
6
2
7.0
3
0
.9
4
8
EW
E0
54
1
33.
8
4
7
.4
339
7
1
2
0
4
2
3
.1
19.
8
2
6.3
3
0
.7
48E
WD
/EYD
05
8
1
32.
1
4
7
.5
335
4
1
2
0
7
2
2
.9
19.
5
2
6.5
3
1
.1
4
8
EW
E0
58
1
39.
5
4
9
.6
354
4
1
2
6
0
2
5
.3
19.
6
2
4.1
3
1
.1
48E
WD
/EYD
06
4
1
25.
3
4
5
.2
318
1
1
1
4
9
2
0
.7
19.
6
2
9.1
3
0
.7
4
8
EW
E0
64
1
32.
2
4
7
.2
335
9
1
1
9
9
2
2
.8
19.
7
2
6.7
3
0
.8
48E
WD
/EYD
06
8
1
27.
7
4
6
.6
324
2
1
1
8
4
2
1
.7
19.
3
2
7.7
3
1
.2
4
8
EW
E0
68
1
34.
7
4
8
.6
342
2
1
2
3
5
2
3
.9
19.
4
2
5.4
3
1
.3
Summary of Contents for WEATHERMAKER 48AJ020
Page 3: ...3 Fig 1 Roof Curb 48AJ AK020 030 and 48EJ EK024 034 Units ...
Page 4: ...4 Fig 2 Roof Curb 48AJ AK034 050 and 48EJ EK038 048 Units ...
Page 5: ...5 Fig 3 Roof Curb 48AJ AK060 and 48EJ EK054 068 Units ...
Page 97: ...97 Fig 78 Typical 48EK VAV 24 V Control Circuit ...
Page 99: ...99 Fig 80 Typical 48EK VAV 115 V Control Circuit ...
Page 100: ...100 Fig 81 Typical 48EJ CV 115 V Control Circuit ...
Page 101: ...101 Fig 82 Label Diagram Staged Gas Heat 48AJ AK AW AY020 050 and 48EJ EK EW EY024 048 Units ...
Page 102: ...102 Fig 83 Label Diagram Staged Gas Heat 48AJ AK AW AY060 and 48EJ EK EW EY054 068 Units ...