Cleaning and maintenance 

 
In order to maintain its optimum function and low 
energy consumption the cabinet should be shut off 
and cleaned at least every other month. 
 

  Empty the cabinet. 

  Pull out the mains plug and wait for the cabinet to 

reach room temperature. 

   Do not lift out the goods tray. Cleaning under the 

goods tray should be carried out only by service 
person!  

  It is easier to remove the goods tray if the light 

box, which is fixed loosely, is removed first. 
Thereafter remove the night cover (accessory). 
Grip the down bent edge on the goods tray and 
lift it up in one edge and then lift it out of the 
cabinet, see picture  (6.2). This operation should 
be carried out only by service person! 

  To put the goods tray back into position remount 

in reversed order. 

  Clean it with a damp cloth using hot water and a 

mild detergent. Wipe clean with a dry cloth. Do 
not pour water into the cabinet. 

 

  Vacuum clean the grille, which is located on the 

inside of the fan on the cabinet front (5), free 
from dust and check that no litter blocks the 
ventilation openings. Check that the mains cable 
is free from damages. 

 

Reversible air flow through the condenser during 
defrost helps to keep clean the condenser. For 
undisturbed operation it is recommended to check 
the dirtyness of condenser at every periodic 
maitanance and in case of dirty sourrounding clean 
it monthly. The extent of pollution can normally be 
reduced by 2/3 with the reversible fan. To access 
the condenser see instruction: 

 

Mounting/dismounting of side cover. 

 

 
Fault tracing - The temperature in the 
cabinet is too high 

 

  Is the mains cable connected? 

  Is the fuse intact? 

 On 

defrost? 

  Cabinet overloaded with products? 

  Is the condenser free from dust and are the air 

inlets clear? 

  Sitting fault? See sitting of the cabinet above. 

  Is the controller set too warm? Normal setting 

see "Technical Data" 

 
If the cabinet still does not function after these 
checks a service company should be contacted. The 
cabinet must only be serviced by an authorised 
service technician. In the goods compartment there 
is a manual which could be of help to the technician. 
 
Faults occurring during the guarantee period are 
covered by the guarantee with the following 
exceptions: 
 

  Transport damage and fair wear and tear. 

  Adjustment of controller. 

  Fuses, fluorescent tubes, starters or similar. 

  Problems in connection with an incorrect 

installation, abnormal use and non-
maintenance. 

Move the goods to another cabinet if possible or put 
a night cover on the cabinet to keep the temperature 
longer. 
 
 
 

Repair instructions 

  
Pull out the mains plug and wait for the cabinet to 
reach room temperature. 
 

Replacement of compressor 

 
Move the service pipe with the schrader valve to the 
new compressor. 
Always exchange the drier. 
 

Mounting/dismounting of side cover 

 
Dismount the cover by starting to unscrew the 
screws in the lower edge of the plate (6.1). When 
the screws are gone the cover will slowly fall to the 
floor by its own weight. Now push the cover a little 
upwards and to the right or left to ensure a gap 
between the plate and the corner piece as shown in 
sketch (6.1). Let the plate down in order to loosen it 
in the upper part. Thereafter angle out the plate in 
the end, which has a gap, and then remove the 
plate. 
Mount in reversed order. 
Replacement of mains supply cable 

Summary of Contents for TULIP TC17C-SA

Page 1: ...anleitung Read this before you start using the medium temp gondola Bitte lesen Sie diese Hinweise vor der Inbetriebnahme TULIP TC17C SA TC17C BA Carrier CR Hungary Ltd PO Box 23 H 5123 J sz roksz ll s...

Page 2: ...rical equipment is connected as otherwise there is a risk that the fuse will blow Also make sure that the mains cable is placed to avoid damage and the possibility of being tripped over Loading and us...

Page 3: ...icherung ausf llt Stellen Sie auch sicher dass das Hauptanschlusskabel richtig platziert ist um seine Besch digung sowie eine Stolpergefahr zu verhindern Best ckung und Gebrauch Warten Sie mindestens...

Page 4: ...temperature in the cabinet is too high Is the mains cable connected Is the fuse intact On defrost Cabinet overloaded with products Is the condenser free from dust and are the air inlets clear Sitting...

Page 5: ...ass is remounted with the correct side facing down The LE layer must be pointing down Loosen the 2 screws holding the LE glass placed on the bottom of the light box Carefully bend up the plate edges w...

Page 6: ...ebenfalls berpr ft werden Bei schmutzigen und staubigen Umgebungsbe dingungen sollte der Kondensator monatlich gereinigt werden Das Ausma der Verschmutzung kann normalerweise durch den umkehrbaren L f...

Page 7: ...higungsnachweis ausgewechselt werden Austausch der Leuchtstoffr hre L sen Sie die zwei Schrauben mit denen der Leuchtaufsatz angeschraubt ist Bevor Sie mit der Demontage beginnen markieren Sie die Gl...

Page 8: ...TC17C 36 22 520 02 4 1 2 3 4 6 1 6 2 5...

Reviews: