To consider when sitting the cabinet 

 

 

Place the cabinet so that it is not influenced by 
heating equipment (radiators, baking ovens, 
sunlight etc.) or draught (ventilation system, open 
doors, signs above it etc.). Every influence will 
impair the performance and give higher energy 
consumption. 

 

Also be sure to keep good air circulation in the 
machine compartment. See to it that the venti- 
lation openings are not blocked with card-board 
boxes or similar placed on the floor. (2)  

  The cabinet must be level. This ensures good 

function during operation and defrost. 

  The cabinet has its optimum function at an 

ambient temperature between 15 and 25

˚

C. At 

higher temperatures than 30

˚

C the cabinet should 

not be used. 

 

To do before you start using the cabinet 

 

 

Clean the cabinet with a damp cloth using hot 
water and a mild detergent. Wipe clean with a dry 
cloth. Use special glass detergents for the glass to 
avoid water deposits. 

 

Important to know about the electrical 
supply 

 

  Connect only to earthed mains supply, rating see 

data plate, fused with at least a 10 Amp slow fuse. 
Make sure that no other electrical equipment is 
connected, as otherwise there is a risk that the 
fuse will blow. Also make sure that the mains cable 
is placed to avoid damage and the possibility of 
being tripped over. 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

Loading and use

 

 

  Wait 1 hour after transport the cabinet to its final 

position then connect to the electrical supply. 

  

 

Let the cabinet be cold before loading. 

 

Use only prepacked goods max 32°C. 

 

Do not load higher than the loadline sign (3). 

 

Do not throw in heavy goods. 

 

The electronic controller is set from the factory. If 
another temperature is wanted ask factory for 
correct settings. The electronic controller is placed 
behind the end wall plate to the right seen from 
the front (4). Adjustments must only be carried out 
by authorized technian. 

 

The thermometer normally show ca 2

˚

C but could 

during defrost, which takes place a couple of 
times every 24h, show up to 5

˚

C for a short while. 

The thermometer could show ca -2

˚

C before the 

end of pull down. 

 

We congratulate you on having chosen this quality product. If you follow the simple instructions and advises 
below, this cabinet will maintain its high performance, safety and low energy consumption.

 

 

The cabinet is meant for storage and display of refrigerated food packages and should not be used for the 
storage of other products.

 

 

Please keep this instruction for further use.

 

Summary of Contents for TULIP TC17C-SA

Page 1: ...anleitung Read this before you start using the medium temp gondola Bitte lesen Sie diese Hinweise vor der Inbetriebnahme TULIP TC17C SA TC17C BA Carrier CR Hungary Ltd PO Box 23 H 5123 J sz roksz ll s...

Page 2: ...rical equipment is connected as otherwise there is a risk that the fuse will blow Also make sure that the mains cable is placed to avoid damage and the possibility of being tripped over Loading and us...

Page 3: ...icherung ausf llt Stellen Sie auch sicher dass das Hauptanschlusskabel richtig platziert ist um seine Besch digung sowie eine Stolpergefahr zu verhindern Best ckung und Gebrauch Warten Sie mindestens...

Page 4: ...temperature in the cabinet is too high Is the mains cable connected Is the fuse intact On defrost Cabinet overloaded with products Is the condenser free from dust and are the air inlets clear Sitting...

Page 5: ...ass is remounted with the correct side facing down The LE layer must be pointing down Loosen the 2 screws holding the LE glass placed on the bottom of the light box Carefully bend up the plate edges w...

Page 6: ...ebenfalls berpr ft werden Bei schmutzigen und staubigen Umgebungsbe dingungen sollte der Kondensator monatlich gereinigt werden Das Ausma der Verschmutzung kann normalerweise durch den umkehrbaren L f...

Page 7: ...higungsnachweis ausgewechselt werden Austausch der Leuchtstoffr hre L sen Sie die zwei Schrauben mit denen der Leuchtaufsatz angeschraubt ist Bevor Sie mit der Demontage beginnen markieren Sie die Gl...

Page 8: ...TC17C 36 22 520 02 4 1 2 3 4 6 1 6 2 5...