background image

Copyright 2001 CARRIER Corp. • 7310 W. Morris St. • Indianapolis, IN 46231

tstat-26si

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book 1

4

Tab

misc miscPC 101

Catalog No. O3TS-TA32

Printed in U.S.A.

Form TSTAT-26SI

Pg 8

9/01

Replaces: TSTAT-24SI

Summary of Contents for Standard Programmable Thermostat

Page 1: ...ime appears on the display press the HOLD END button NOTE If you choose not to press the HOLD END button the thermostat will automatically exit the time setting mode after 10 sec SETTING THE CURRENT DAY 1 Press the DAY button to advance to the correct day MANUAL OPERATION TO OPERATE MANUALLY WITHOUT THE PRO GRAMMED COMFORT SCHEDULE Press the HOLD END button to make the HOLD icon appear Then follow...

Page 2: ...mporary Override At the first press of the UP or DOWN button the current temperature setting will appear on the display Pressing the UP or DOWN button again will temporarily change the set point as needed At the next programmed time the programmed comfort schedule will resume INSTALLATION START UP AND OPERATING INSTRUCTIONS INTRODUCTION The Standard Programmable Thermostat is an electronic 24 vac ...

Page 3: ...llowing options are available OPTION 1 ANTICIPATOR VALUE ADJUSTMENT This adjustment controls the sensitivity and cycle rate of the thermostat Higher numbers decrease the cycle rate Lower num bers increase the cycle rate However this feature will not allow more than 4 equipment cycles per hour or 1 cycle every 15 minutes regardless of setting Values can range from 1 to 3 Factory default setting is ...

Page 4: ...ER In normal heating and cooling operation the thermostat will not allow more than 4 equipment cycles per hour or 1 cycle every 15 minutes Both the Y and W outputs have a 15 minute timer that starts counting down when the output is turned on e g if Y output is turned on for 9 minutes and then satisfies it cannot turn back on for another 6 minutes regardless of demand However pressing UP and FAN bu...

Page 5: ...VALVE REVERSING HEAT COOL STAGE 1 HEATING FAN 24 VAC HOT 24 VAC COMM COOLING N A W G R C Y W G R C Y AC THERMOSTAT TYPICAL FAN COIL FURNACE See note 1 O A01400 Fig 3 Typical Heat Only HEATING FAN 24 VAC HOT 24 VAC COMM COOLING N A W G R C W1 G R C Y Y1 AC THERMOSTAT TWO ZONE THERMOSTAT INPUT O A01401 Fig 5 Two Zone with Air Conditioner NOTE 1 It is recommended to use a 5 wire hookup whenever possi...

Page 6: ...iguration Options 1 _____ Anticipator 1 3 factory default 2 2 _____ N A 3 _____ Fahrenheit or Celsius F or C factory default F 4 _____ Fan On with W Off or On factory default Off 5 9 _____ N A 10 _____ O reversing valve On with Heat or Cool H or C factory default C 11 12 _____ N A 13 _____ Room Temperature Offset 5 to 5 factory default 0 C Schedule MORNING DAY EVE NIGHT TIME HEAT COOL TIME HEAT CO...

Page 7: ...7 ...

Page 8: ... tstat 26si Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations Book 1 4 Tab misc miscPC 101 Catalog No O3TS TA32 Printed in U S A Form TSTAT 26SI Pg 8 9 01 Replaces TSTAT 24SI ...