PHR5: Owner’s Information Manual

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

3

Defrost Mode

When your unit is providing heat to your home or office and the outdoor

temperature drops below 45°F (7.2°C), moisture may begin to freeze on

the surface  of the  coil. If  allowed  to  build up,  this  ice  would  impede

airflow across the coil and reduce the amount of heat absorbed from the

outside air. So, to maintain energy-efficient operation, your unit has an

automatic defrost mode.
The defrost mode starts at a preset time interval of 60 minutes, although,

it may be reset to 30, 90 or 120 minutes. Defrost will start at the preset

time  only  if  the  ice  is  sufficient  to  interfere  with  normal  heating

operation.
After the ice is melted from the coil, or after a maximum of 10 minutes

in defrost mode, the unit automatically switches back to normal heating

operation.
Do not be  alarmed  if steam  or fog  appears at  the outdoor unit  during

defrost  mode. Water  vapor  from  the melting  ice  may condense  into  a

mist in the cold outside air.
During certain weather conditions such as heavy snow and freezing rain

it is not uncommon for ice to build up on the unit grille. This is normal

for these weather conditions. Do not attempt to remove the ice from the

unit grille. This condition will not affect the proper function of the unit

and will clear within a few days.

Emergency Heating Mode

In  the  event  of  primary  unit  heat  failure,  the  emergency  heat  mode

allows your supplemental heating  source  to keep your home or  office

warm until your unit can be serviced.  Contact your dealer in the event of

primary unit heat failure.

Maintenance and Service

This  section  discusses  maintenance  that  should  be  performed on  your

system. Most maintenance should be performed by your dealer. You, as

the owner, may wish to handle some minor maintenance for your new

unit.

Routine Maintenance

All  routine  maintenance  should  be  handled  by  skilled,  experienced

personnel. Your dealer can help you establish a standard procedure.
To assure proper functioning of the unit, flow of condenser air must not

be obstructed from reaching the unit. Clearance from the top of the unit

is 48 in. (1219 mm). Clearance of at least 36 in.(914 mm) is required on

sides except the power entry side (42 in. [1067 mm] clearance) and the

duct side (12 in. [305  mm] minimum clearance).

Maintenance and Care for the Equipment Owner

Before  proceeding  with  those  things  you  might  want  to  maintain

yourself, please carefully consider the following:

Air Filters

The air filter(s) should be checked every 3 or 4 weeks and changed or

cleaned whenever it becomes dirty. Dirty filters produce excessive stress

on the blower motor and can cause the motor to overheat and shut down.
This unit must have air filters in place before it can be operated.  These

filters can be located in one of at least two places. In many applications,

the installer will provide return air filter grilles mounted on the wall or

ceiling of the conditioned structure. In the instance of filter grilles, the

filters can simply be removed from the grille and replaced.
The other typical application is an accessory filter rack installed  inside

the unit itself. The following information is given to assist in changing

filters used in these internal filter racks.

Table 1

indicates  the  correct  indoor  filter  size  for  your  unit.  Refer  to

Fig. 2

 to access filters installed in the accessory filter rack. If using an

Accessory  Filter  Rack,  refer  to  the  Installation  Instructions  provided

with it for correct filter sizes and quantities.

Table 1 – Indoor Air Filter Data

To replace or inspect filters in accessory filter rack (See 

Fig. 2

):

1. Remove the filter access panel using a 5/16-in. nut driver.
2. Remove the filter(s) by pulling it out of the unit. If the filter(s) is

dirty, clean or replace with a new one.

When installing the new filter(s), note the direction of the airflow arrows

on the filter frame, which should be pointed at the indoor coil.

3. Reinstall filter access panel ensuring opening is air and water tight.

If  you  have  difficulty  locating  your  air  filter(s)  or  have  questions

concerning  proper  filter  maintenance,  contact  your  dealer  for

instructions. When replacing filters, always use the same size and type of

filter that was supplied originally by the installer.

A09044

Fig. 2 – Unit Access Panel

WARNING

!

FIRE, EXPLOSION, ELECTRICAL SHOCK AND CUT 

HAZARD

Failure to follow this warning could result in personal injury, death or

property damage.

1. TURN  OFF  ELECTRICAL  POWER  TO  YOUR  UNIT

BEFORE SERVICING OR PERFORMING MAINTENANCE.

Lock out and tag switch with a suitable warning label.

2. When  removing  access  panels  or  performing    maintenance

functions inside your unit, be aware of sharp sheet metal parts

and  screws.  Although  special  care  is  taken  to  reduce  sharp

edges to a minimum, be extremely careful when handling parts

or  reaching  into  the  unit.  Wear  safety  glasses,  glove,  and

appropriate protective clothing.

Unit Size

Filter Size in. (mm)

24

20x20x1 (508x508x25)

30

20x24x1 (508x610x25)

36-42

24x30x1 (610x762x25)

48-60

24x36x1 (610x914x25)

CAUTION

!

UNIT OPERATION HAZARD

Failure to follow this caution may result in property damage.
Never  operate  your  unit  without filters  in place. An  accumulation of

dust and lint on internal parts of your unit can cause loss of efficiency

and blower motor and/or compressor damage.

Access Panels

Filter Access Panel

For Accessory Filter Rack