                    CARRIER CORPORATION ©2011 

                    A member of the United Technologies Corporation family · Stock symbol UTX · Catalog No. 11-808-435-01 · 6/20/2011 

 

Summary of Contents for OPN-VVTZC

Page 1: ...ro ol ll le er r I In ns st ta al ll la at ti io on n a an nd d S St ta ar rt t u up p G Gu ui id de e CARRIER CORPORATION 2011 A member of the United Technologies Corporation family Stock symbol UTX...

Page 2: ......

Page 3: ...ifications 15 To wire the SAT sensor to the controller 15 Wiring a Duct Air Temperature sensor 16 Wiring specifications 16 To wire the DAT sensor to the controller 16 Wiring a CO2 sensor 17 Wiring spe...

Page 4: ...40 Temperature sensors 40 Zone airflow control 41 Zone reheat control 42 Demand control ventilation DCV and dehumidification using optional sensors 43 Occupancy 44 Alarms 45 Demand limiting 46 Linkag...

Page 5: ...duct and fan box terminals with modulating heat up to 2 stages of ducted heat or combination baseboard and ducted heat The i Vu Open Control System uses linkage to exchange data between the zone termi...

Page 6: ...s To ReduceThe Risk of Fire or Electric Shock Do Not CAUTION BACnet VVT Zone AO 0 10 Vdc 5mAMax Local Access Short pins Enable SAT Enable SAT and REMOTE CW CCW Motor Error Run Power 0 5Vdc Made in USA...

Page 7: ...ZCSENSRH 01 indoor space or 33ZCSENDRH 01 duct Remote occupancy sensor Input resolution 10 bit A D Digital outputs 3 digital outputs relay contact rated at 1 A max 24 Vac Vdc Configured normally open...

Page 8: ...e with NEC Section 300 22 c and d Overall dimensions A B C 7 in 17 8 cm 6 1 32 15 4 cm 6 in 15 24 cm Mounting dimensions D E F G H 5 5 8 in 14 3 cm 4 9 16 in 24 3 cm 1 5 16 in 3 3 cm 7 8 in 2 2 cm 1 5...

Page 9: ...ETY NOTE Good judgment should be used in applying any manufacturer s instructions to avoid injury to personnel or damage to equipment and property Failure to follow this warning could cause personal i...

Page 10: ...terminal unit round or rectangular mounting bracket space temperature sensor supply air temperature sensor 4x2 in electrical box transformer 24 Vac 40 VA two no 10 x 1 2 in sheet metal screws to secu...

Page 11: ...per 2 Remove the controller s cover 3 Mount the controller to the VVT box by sliding the clamp assembly onto the damper shaft Damper Shaft VVT Box Controller Anti rotation slot 4 Secure the controller...

Page 12: ...See figure below b Move the stop clamp until it contacts the edge of the actuator cam c Tighten the screw Move stop clamp if necessary 9 Hold down the damper release button rotate the damper to verif...

Page 13: ...address the VVT Zone Controller You must give the VVT Zone Controller an address that is unique on the network You can address the VVT Zone Controller before or after you wire it for power 1 If the VV...

Page 14: ...e to echoing See the MS TP Networking and Wiring Installation Guide for more details Wiring specifications Cable 22 AWG or 24 AWG low capacitance twisted stranded shielded copper wire Maximum length 2...

Page 15: ...y Air Temperature sensor page 15 Duct Air Temperature sensor page 16 CO2 sensor Relative Humidity sensor page 19 Remote occupancy contact sensor page 20 NOTE This document gives instructions for wirin...

Page 16: ...of the following combinations of devices wired in a daisy chain configuration 1 SPT Plus or SPT Pro 1 4 SPT Standards 1 4 SPT Standards and 1 SPT Plus or SPT Pro Any of the above combinations plus up...

Page 17: ...k the inner insulation Strip about 25 inch 6 cm of the inner insulation from each wire Outer Jacket Inner insulation 25 in 6 cm 2 Wire each terminal on the sensor to the same terminal on the controlle...

Page 18: ...f 100 ft 30 5 meters 22 AWG shielded Maximum length 500 feet 152 meters To wire the T55 sensor to the controller 1 Strip the outer jacket from the cable for at least 3 inches 7 62 cm Strip 25 inch 6 c...

Page 19: ...zone controller is equipped with ducted heating Wiring specifications Cable from sensor to controller If 100 ft 30 5 meters 22 AWG unshielded If 100 ft 30 5 meters 22 AWG shielded Maximum length 500 f...

Page 20: ...100 ft 30 5 meters 22 AWG unshielded If 100 ft 30 5 meters 22 AWG shielded Maximum length 500 feet 152 meters To wire the DAT sensor to the controller 1 Wire the sensor to the controller See diagram...

Page 21: ...ASPCO2 The sensor has a range of 0 2000 ppm and a linear 4 20 mA output This is converted to 1 5 Vdc by a 250 Ohm 1 4 watt 2 tolerance resistor connected across the zone controller s CO2 input termina...

Page 22: ...33ZCT55CO2 1 Wire the sensor to the controller See appropriate diagram below 2 Install a field supplied 250 Ohm 1 4 watt 2 tolerance resistor across the controller s RH CO2 and Gnd terminals 3 Verify...

Page 23: ...trol dehumidification if the rooftop unit has a dehumidification device If not the sensor only monitors humidity NOTE Do not use a relative humidity sensor and CO2 sensor on the same zone controller W...

Page 24: ...controller See diagram below 3 Using electrical tape insulate any exposed resistor lead to prevent shorting 4 Verify that the RH CO2 jumper is set to 0 5Vdc 5 Set SW3 on the sensor as shown below Wiri...

Page 25: ...25 Fan box modulating hot water page 25 Fan box combination base board and ducted heat page 26 Fan box 2 stage electric heat page 26 Disconnect electrical power to the VVT Zone Controller before wiri...

Page 26: ...d HWV CO2 LED REMOTE RH SAT SPT T55 OPT Ground Hot water valve CO2 sensor Not used Remote occupancy sensor Relative humidity sensor Supply air temperature sensor Space temperature sensor Alternate spa...

Page 27: ...VVT Zone Controller 23 Single duct 2 position hot water Single duct modulating hot water...

Page 28: ...Installation 24 VVT Zone Controller Single duct combination base board and ducted heat Single duct 2 stage electric heat...

Page 29: ...VVT Zone Controller 25 Fan box 2 position hot water Fan box modulating hot water ducted or baseboard...

Page 30: ...Installation 26 VVT Zone Controller Fan box combination baseboard and ducted heat Fan box 2 stage electric heat...

Page 31: ...stead of using the controller s built in 35 in lb actuator NMX24 MFT P 10028 90 in lb actuator with 0 10 Vdc control and 0 10 Vdc feedback AMX24 MFT P 10028 180 in lb actuator with 0 10 Vdc control an...

Page 32: ...Vdc control AMX24 MFT P 10028 180 in lb actuator with 0 10 Vdc control 1 Install the actuators according to the manufacturer s instructions 2 Wire the actuators to the controller using the diagram be...

Page 33: ...oller s Rnet port Permanent interface 2 1 Requires a USB Link USB L 2 See the BACview Installation and User Guide for instructions on connecting and using the above items Configuring the VVT Zone Cont...

Page 34: ...falls below a fixed hysteresis of 2 F This function is active only if there is a valid network outside air temperature R 70 F 60 to 150 F Setpoint properties i Vu Field Assistant Navigation BACview P...

Page 35: ...scheduled occupancy begins This learning adaptive algorithm uses the learned heating capacity and learned cooling capacity values to calculate the effective setpoints prior to the occupied start time...

Page 36: ...unoccupied setpoints over a specified period of time to achieve the occupied setpoint by the time scheduled occupancy begins When selecting None or Temp Compensated D you MUST set all Learning Adapti...

Page 37: ...f the damper is rectangular enter its area width x height If the damper is round enter 0 R 0 sq in 0 to 9999 sq in External Actuator Enable D Enable if the controller s analog output is used for an ex...

Page 38: ...mum damper position the terminal controls to when the air source mode is Heat and the space requirements are at a minimum R 20 0 to 100 Heating Max Damper Position D The maximum damper position the te...

Page 39: ...system R 1 1 to 64 Performing system checkout 1 Verify that all power and communication connections are correct and tight 2 Verify that all zone terminals ductwork and zone controllers are properly i...

Page 40: ...Status shows Active CAUTION Pressing the actuator release button and moving the damper or disconnecting the actuator ribbon connector while the bypass controller is powered will cause the damper posi...

Page 41: ...measuring devices Make adjustments using the manual volume damper located upstream of the zone damper Series Fan zone terminals Click Damper Full Close to override the zone damper to its fully closed...

Page 42: ...rce is designed to deliver at its maximum design airflow in CFM supplied by the mechanical design engineer The maximum cooling or heating whichever is greater CFM requirements for all zones connected...

Page 43: ...the following a For an RTU Open or WSHP Open controller go to Properties Equipment Configuration Service Configuration Service Test and disable Service Test and Fan Test b For any equipment whose wiri...

Page 44: ...e must be written to the BACnet space temperature point system_spt at 1 to 5 minute intervals or on a COV of 0 1 F To reference another zone as your space temperature input read the BACnet point zone_...

Page 45: ...n to increase airflow at the zone s diffusers and prevent cold air from dumping into the zone when the system mode is Cool This is achieved by increasing the volume and temperature of the air exiting...

Page 46: ...eating mode and is controlled so that the SAT does not exceed the Maximum Heating SAT 105 F default For non ducted baseboard heating the valve is controlled to keep the zone s temperature at the heati...

Page 47: ...to increase If the sensor s value exceeds the DCV Max Ctrl Setpoint the controller modulates the damper to its DCV Max Vent Damper Position When the zone is unoccupied the Cooling Min Damper Position...

Page 48: ...ate based on whether or not the space is actually occupied If the occupancy sensor contact is in the same state as Occ Override Normal Logic State setting the zone follows its normal occupancy schedul...

Page 49: ...00 rh default The controller provides a 30 minute alarm delay during unoccupied periods During occupied periods the controller uses the Occ High RH Alarm Limit When a transition from unoccupied to occ...

Page 50: ...er than or equal to the number of configured Linkage Callers Heating if the number of occupied zones with a heating demand exceeds or is equal to the number of Linkage Callers If no zones are occupied...

Page 51: ...ECOOL Air source fan is on and providing cooling using economizer only COOL Air source fan is on and cooling is provided by economizer and mechanical cooling PRESSURIZATION Fire Life safety override i...

Page 52: ...The actuator motor is turning counterclockwise CCW The Run and Error LED s indicate controller and network status If Run LED shows And Error LED shows 1 flash per second Status is 1 flash per second a...

Page 53: ...emory to the VVT Zone Controller Replace the VVT Zone Controller Serial number If you need the VVT Zone Controller s serial number when troubleshooting the number is on a sticker on the back of the ma...

Page 54: ...to cause harmful interference in which case the user will be required to correct the interference at his own expense CAUTION Changes or modifications not expressly approved by the responsible party fo...

Page 55: ...R The current supply air temperature 56 to 245 F Heating Capacity R The current reheat capacity when the zone is configured for reheat 0 to 100 Baseboard Heating Capacity R The current modulating bas...

Page 56: ...9999 hr Pushbutton Override D Enables or disables the use of a pushbutton override from a local space temperature sensor R Enable Disable Enable Setpoint Adjust D Enables the setpoint adjustment slide...

Page 57: ...or to be adjusted to match a calibrated standard measuring the temperature in the same location R 0 F 9 9 to 10 F Space Relative Humidity R Displays the current value of relative humidity sensor if pr...

Page 58: ...upied mode 75 F 76 F 78 F Occupied Heating 1 Light Blue The space temperature must be less than this value for the VVT Master to consider the zone a heating caller The zone remains a heating caller un...

Page 59: ...9 F Unoccupied Cooling 2 D Orange The space temperature must be greater than this value before a high space temperature alarm is generated R 93 F 40 to 99 F Point Name Description Range Heating Capaci...

Page 60: ...ver a specified period of time to achieve the occupied setpoint by the time scheduled occupancy begins This learning adaptive algorithm uses the learned heating capacity and learned cooling capacity v...

Page 61: ...he setpoints do not ramp but change immediately from unoccupied to occupied values Learning Adaptive Start Unit gradually changes to occupied setpoints by adjusting the unoccupied setpoints over a spe...

Page 62: ...stablish the occupied high and low limits that the space temperature must exceed before an occupied SPT alarm is generated The alarm returns to normal when the space temperature drops below the high e...

Page 63: ...trol is set to Enable There is a fixed hysteresis of 100ppm for return to normal R 1100ppm 0 to 9999 ppm Alarm Delay min ppm The fractional portion of an hour determining the amount of delay before an...

Page 64: ...t may be used with system heat depending on the space temperature demand Options None no heat Modulating ducted or baseboard modulating hot water Two Position two position hot water Staged EH ducted o...

Page 65: ...the CO2 D sensor s low voltage reading R 0ppm 0 to 9999 ppm CO2 Sensor Value Max Volts The ppm value that correlates to the CO2 D sensor s high voltage reading R 2000 ppm 0 to 9999 ppm PD Pressure Dep...

Page 66: ...resume normal control Calibrated Damper Open Forces the damper to its maximum open position so that the 100 damper position can be set Cool Max Forces the damper to its cool maximum position regardles...

Page 67: ...ailed SPT Sensor An SPT sensor is connected to the controller s Rnet port T55 56 A T55 T56 or T59 sensor is connected to the controller s J20 terminals Network A network temperature sensor is bound to...

Page 68: ...rt the Filter Service Alarm Timer After the alarm returns to normal this automatically changes to Off D R Off On Off Occupancy Contact State The physical state of the Remote input R Open Closed Occupa...

Page 69: ...he high temperature alarm limit or drops below the low temperature alarm limit R Normal Alarm Filter Indicates if the filter s runtime hours exceeds the runtime alarm limit R Clean Dirty Space Relativ...

Page 70: ...stems increase the number by 1 for each 6 zones For example 3 linkage callers for a 20 zone system D R 1 1 to 32 System Mode Reselect Timer minutes Applies only to a VVT master Defines how long the sy...

Page 71: ...s Details tab are listed below For more information consult the Carrier Sensors Installation Guide Zone Temp do not adjust these settings R 56 to 245 F Sensor Type Min Present Value Minimum present va...

Page 72: ...Temp The value of the controller s T55 space temperature sensor input R 56 to 245 F SAT Sensor The current value of the controller s SAT input R 56 to 140 F Occupancy Contact State The hardware state...

Page 73: ...Modulate Damper Position Cool Disable Disable Heating Single Duct Parallel Fan No Cooling Minimum Damper Position Cool Disable Disable Series Fan No Heating Minimum Damper Position Cool Disable Enable...

Page 74: ...Heating Modulate Damper Position Heat Disable Enable Series or Parallel Fan Yes Heating Modulate Damper Position Heat Enable Enable Pressurization Linked air source only None Single Duct Parallel Fan...

Page 75: ...t 51 Field supplied hardware 6 12 I I O Points 67 Input resolution 3 Inputs 3 11 i Vu 29 51 L LED s 3 48 Linkage 1 45 46 Linkage properties 29 34 65 Listings 3 Local Access port 3 Local schedules 44 M...

Page 76: ...t 45 58 Hot Water Valve 67 Hysteresis 30 53 IAQ Ventilation alarm 58 IAQ Sensor 60 IAQ Source 63 Indoor Air Quality 65 Indoor Air Quality Alarm 45 65 Inhibit Cooling Call from this zone 65 Inhibit Hea...

Page 77: ...Temperature 60 System Space IAQ 60 System Space RH 60 System Space Temperature 60 T55 Override Duration 52 T55 56 63 Target damper position 60 Temp Compensated Start 63 Tempurature Compensated 53 Term...

Page 78: ...agram 26 Fan box modulating hot water ducted or baseboard wiring diagram 25 Inputs 3 11 Output 21 Single duct 2 position hot water wiring diagram 23 Single duct 2 stage electric heat wiring diagram 24...

Page 79: ......