These instructions are intended to be used by qualified
personnel who have been trained in installing this type of
furnace. Installation of this furnace by an unqualified person
may lead to equipment damage and/or a hazardous condition
which may lead to bodily harm.
All local and national code requirements governing installation of
oil burning equipment, wiring, and flue connections must be
followed. Some of the codes (issued by the Canadian Standards
Association, the National Fire Protection Agency, and/or the
American National Standards Institute) that may be applicable are:
ANSI/NFPA 31
INSTALLATION OF OIL BURNING
EQUIPMENT
ANSI/NFPA 211
CHIMNEYS, FIREPLACES, VENTS,
AND SOLID FUEL BURNING
APPLIANCES
ANSI/NFPA 90B
WARM AIR HEATING AND AIR
CONDITIONING SYSTEMS
ANSI/NFPA 70
NATIONAL ELECTRICAL CODE
CSA B139
INSTALLATION CODE FOR
OIL BURNING EQUIPMENT
CSA C22.1
CANADIAN ELECTRICAL CODE
Only the latest issues of these codes should be used, and are
available from either: The National Fire Protection Agency,
Batterymarch Park, Quincy, MA 02269, or The Canadian Stan-
dards Association, 178 Rexdale Blvd., Rexdale, Ontario M9W
1R3
Recognize safety information. This is the safety-alert symbol
.
When you see this symbol on the furnace and in instructions or
manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, and CAU-
TION. These words are used with the safety-alert symbol. DAN-
GER identifies the most serious hazards which will result in severe
personal injury or death. WARNING signifies a hazard which
could result in personal injury or death. CAUTION is used to
identify unsafe practices which would result in minor personal
injury or product and property damage.
Fig. 2—Dimensional Drawing
DIMENSIONS (IN.)
UNIT SIZE
A
B
C
D
E
F
G
H
J
K
L
105-12
35
48-3/4
30-1/4
16-5/8
20
22
12
14
5
1-1/2
1-3/4
120-20
39-1/2
53
32-1/4
18-3/4
24
28
12-9/32
16
6
1-5/8
1-1/2
A98037
3
″
19
″
20
″
20
″
19
″
2
″
PULL
OIL INLET
(BOTH SIDES)
VENT CONN
ELECTRICAL
CONNECTIONS
(BOTH SIDES)
.88 DIAM TYP
KNOCK-OUT BOTH SIDES
FOR J DIAM VENT
TOP KNOCK-OUT
FOR J DIAM VENT
A
E
G
B
L
H
C
D
F
K
2