background image

 

L

L

o

o

n

n

W

W

o

o

r

r

k

k

s

s

 

 

I

I

n

n

t

t

e

e

g

g

r

r

a

a

t

t

i

i

o

o

n

n

 

 

G

G

u

u

i

i

d

d

e

e

 

 

i

i

-

-

V

V

u

u

®

®

 

 

L

L

i

i

n

n

k

k

 

 

a

a

n

n

d

d

 

 

O

O

p

p

e

e

n

n

 

 

L

L

i

i

n

n

k

k

 

 

 

 

                         

 

 

 

 

                    CARRIER CORPORATION ©2018 

                    A member of the United Technologies Corporation family · Stock symbol UTX · Catalog No. 11-808-430-01 · 5/24/2018 

 

Summary of Contents for LonWorks i-Vu Link

Page 1: ...te eg gr ra at ti io on n G Gu ui id de e i i V Vu u L Li in nk k a an nd d O Op pe en n L Li in nk k CARRIER CORPORATION 2018 A member of the United Technologies Corporation family Stock symbol UTX C...

Page 2: ...ur local Carrier office Important changes are listed in Document revision history at the end of this document CARRIER CORPORATION 2018 All rights reserved throughout the world i Vu is a registered tra...

Page 3: ...Integration Tool 6 To edit an integration point address 8 4 Connect an SLTA 10 to each i Vu Link Open Link on the LonWorks network segment 9 5 Set up the driver properties 10 6 Verify the controller...

Page 4: ......

Page 5: ...upported equipment Any device that supports the LonWorks protocol using SNVT s Network media type EIA 232 to SLTA 10 network adapter Quantity of devices you can physically connect to the i Vu Link Ope...

Page 6: ...50 networks 73354 for RS 485 networks You need 1 adapter for each i Vu Link Open Link that is connected to a LonWorks network segment Make sure you order the model that matches your network topology S...

Page 7: ...r each type of LonWorks device For example VAV Controller or Fan Coil Controller Get from the third party representative www lonmark com the LonWorks device See Appendix B page 20 Device address infor...

Page 8: ...Appendix A page 14 may help you determine whether you need an analog or binary microblock To format a LonWorks address All Lonworks addresses should be assigned to lonworks only when setting up addres...

Page 9: ...at steps 3 12 to add additional control programs and views 12 In the navigation tree select the i Vu Link Open Link in the router list on the right and click Download All Content NOTE This loads the c...

Page 10: ...Field Assistant application 2 Double click the third party controller in the navigation tree A dialog window appears 3 Click Export under Integration Points 4 Click Save 5 Browse to a location on your...

Page 11: ...splay a table of NV s On the row for the SNVT element you want to read from or write to click the Microblock Name field to select the microblock that will do the reading or writing For example to read...

Page 12: ...erl file that you saved from the LonWorks Integration Tool 14 Click Open and then Continue to upload the file 15 Click Close The LonWorks addresses are now set NOTE The LonWorks Integration Tool crea...

Page 13: ...0 s EIA 232 port using one of the following methods If you have an EIA 232 RS 232 straight through cable with connectors and an S2 DB9 Adapter Connect the adapter to the control module s port Then con...

Page 14: ...On the first line of the table Index 0 enter appropriate values in each field See table below 9 In Windows Notepad open the log file that NodeUtil created To see this file in the Notepad Open dialog b...

Page 15: ...pplication uses this authentication code if the third party device requests authentication 10 Click the Apply to refresh the page Verify the following values in the SLTA Node Status section SLTA Comm...

Page 16: ...that has the error you are troubleshooting In the i Vu or Field Assistant interface view the control program s Properties page Network Points tab to see all the refresh times 1 Connect your computer...

Page 17: ...appropriate step 13 14 15 or 16 to turn on capture of that item 14 After diagport type go Press Enter 15 Run the capture for one of the following periods of time If all microblock refresh times are o...

Page 18: ...T_time_stamp 0 year 0 3 000 1 month 1 12 January December 0 month not specified 2 day 1 31 0 day not specified 3 hour 0 23 4 minute 0 59 5 second 0 59 85 SNVT_zerospan 0 zero offset 163 84 163 835 1 s...

Page 19: ...ondition 14 Fire Pre alarm condition 15 Fire Trouble fault condition 16 Fire Supervisory condition 17 Fire Alarm condition in Test Mode 18 Fire Pre Alarm condition in Test Mode 19 Fire Maximum environ...

Page 20: ...normal 1 emergency pressurize 2 emergency depressurize 3 emergency purge 4 emergency shutdown 5 emergency fire 106 SNVT_temp_setpt 0 C occupied cool 273 17 327 66 1 C standby cool 273 17 327 66 2 C u...

Page 21: ...6 Unused The next 16 override values apply to the first device or group 17 Override position percentage use percent field 18 Override flow in liters sec use flow field 19 Override flow percentage use...

Page 22: ...ot conditioned fan turned on 10 Cooling with compressor not running 11 Ice making mode 12 Max Heat 13 Economy 14 Dehumid 15 Calibrate 16 Emergency Cool 17 Emergency Steam 18 Max Cool 19 HVC Load 20 No...

Page 23: ...ble 2 chiller state 1 in alarm 3 1 run is enabled 4 1 local 5 1 limited 6 1 chilled water flow 7 1 conditioned water flow 128 SNVT_tod_event 0 current scheduled occupancy state 0 Area is occupied 1 Ar...

Page 24: ...To obtain and install Echelon software 1 Go to www echelon com downloads 2 Log in or create a new login account 3 In Search for software in select Recommended Downloads click Find then download Open...

Page 25: ...e the service pin on the LonWorks device you want to get information from The device number is displayed in the window CAUTION Holding the service pin for 3 seconds or longer can delete memory from so...

Page 26: ...to install the software 6 Unzip the file that you downloaded for the LonWorks SLTA 10 Serial LonTalk R Adapter Software 7 Run slta10_Win exe to install the software Make note of the numeric base for...

Page 27: ...tion from The device number is displayed in the window CAUTION Holding the service pin for 3 seconds or longer can delete memory from some third party devices TIP For some VAV devices the connected se...

Page 28: ...able with a hub The iLon10 must also be connected to the LonWorks network segment 8 On the computer select Start Control Panel 9 Double click LonWorks Interfaces 10 Click Add 11 Type a name such as iL...

Page 29: ...y also function as a service pin 22 Type G to go to the device menu 23 Type the device number then click Enter 24 Type D then press Enter for all domain tables 25 Type N then press Enter for all netwo...

Page 30: ...All rights reserved 26 Important changes to this document are listed below Minor changes such as typographical or formatting errors are not listed Date Topic Change description Code 5 24 18 Overview A...