Table 3 – Maximum Allowable Exposed Vent Pipe Length -- Ft. (M) With and Without Insulation

in Winter Design Temperature Ambient*

FURNACE

SIZE

WINTER DESIGN

TEMPERATURE

°

F

〈°

C)

MAX PIPE

DIAMETER

IN (mm)

WITHOUT INSULATION

FT (M)

WITH 3/8–IN. (10 mm) OR

THICKER INSULATION†

FT (M)

Fixed Capacity

2---Stage

Fixed Capacity

2---Stage

040

20 (--7)

1.5 (38)

51 (16)

---

70 (21)

---

0 (--18)

1.5 (38)

28 (9)

---

70 (21)

---

--20 (--29)

1.5 (38)

16 (5)

---

70 (21)

---

20 (--7)

2 (51)

45 (14)

---

70 (21)

---

0 (--18)

2 (51)

22 (7)

---

70 (21)

---

--20 (--29)

2 (51)

10 (3)

---

58 (18)

---

060

20 (--7)

2 (51)

65 (20)

44 (13)

70 (21)

70 (21)

0 (--18)

2 (51)

35 (11)

21 (6)

70 (21)

70 (21)

--20 (--29)

2 (51)

20 (6)

20 (6)

70 (21)

57 (17)

080

20 (--7)

2 (51)

55 (17)

55 (17)

55 (17)

55 (17)

0 (--18)

2 (51)

48 (15)

30 (9)

55 (17)

55 (17)

--20 (--29)

2 (51)

30 (9)

16 (5)

55 (17)

55 (17)

20 (--7)

2.5 (64)

70 (21)

58 (18)

70 (21)

70 (21)

0 (--18)

2.5 (64)

47 (14)

29 (9)

70 (21)

70 (21)

--20 (--29)

2.5 (64)

28 (9)

14 (5)

70 (21)

67 (20)

100

20 (--7)

2.5 (64)

40 (12)

40 (12)

40 (12)

40 (12)

0 (--18)

2.5 (64)

40 (12)

38 (12)

40 (12)

40 (12)

--20 (--29)

2.5 (64)

38 (12)

21 (6)

40 (12)

40 (12)

20 (--7)

3 (76)

70 (21)

63 (19)

70 (21)

70 (21)

0 (--18)

3 (76)

50 (15)

30 (9)

70 (21)

70 (21)

--20 (--29)

3 (76)

28 (9)

12 (4)

70 (21)

70 (21)

120

20 (--7)

3 (76)

70 (21)

70 (21)

70 (21)

70 (21)

0 (--18)

3 (76)

61 (19)

38 (12)

70 (21)

70 (21)

--20 (--29)

3 (76)

37 (11)

19 (6)

70 (21)

70 (21)

20 (--7)

4 (102)

70 (21)

65 (20)

70 (21)

70 (21)

0 (--18)

4 (102)

48 (15)

26 (8)

70 (21)

70 (21)

--20 (--29)

4 (102)

23 (7)

5 (2)

70 (21)

65 (20)

140

20 (--7)

3 (76)

60 (18)

---

60 (18)

---

0 (--18)

3 (76)

60 (18)

---

60 (18)

---

--20 (--29)

3 (76)

44 (13)

---

60 (18)

---

20 (--7)

4 (102)

70 (21)

---

70 (21)

---

0 (--18)

4 (102)

57 (17)

---

70 (21)

---

--20 (--29)

4 (102)

30 (9)

---

70 (21)

---

* Pipe Length (ft.) specified for maximum pipe Lengths located in conditioned spaces. Pipes located in unconditioned space cannot exceed total allowable pipe

length as specified in the furnace Installation Instructions. Insulation thickness based on R values of 3.5 (Ft.

2

_

hr.)/(Btu in.).

Copyright 2009 CAC / BDP

D

7310 W. Morris St.

D

Indianapolis, IN 46231

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Catalog No: AG---KGAET---02

Replaces:

AG--KGAET--01

Printed in U.S.A.

Edition Date: 10/09

Summary of Contents for KGAET0101ETK

Page 1: ...rimers and cements from one manufacturer with a vent system from a different manufacturer Follow the manufacturer s instructions in the use of primer and cement and never use primer or cement beyond i...

Page 2: ...kit contains the following items Condensate trap 1 Tee vent fitting 2 in 51 mm PVC 1 Bushing vent fitting 2 x 1 1 2 in 51 x 38 mm PVC 1 Adapter fitting 1 1 2 38 mm male x 1 1 2 38 mm female 1 INSTALLA...

Page 3: ...fitting in place 7 Cement bushing supplied in kit in bottom tee vent fitting connection 8 Position condensate trap supplied in kit in bushing such that drain connection is positioned for suitable fie...

Page 4: ...ondensate trap sides 4 Wrap field drain pipe with remaining heat tape approximately one wrap per ft 5 When using field supplied heat tape follow heat tape manufacturer s instructions for all other ins...

Page 5: ...p and Trap Kit for Vent Above Floor A99082 Fig 4 Upflow Furnace Left Side Outlet with Blower Com partment Condensate Trap Location and Trap Kit for Vent Above Floor A99083 Fig 5 Downflow Furnace Left...

Page 6: ...e Approved Drain A Restricted to maximum of 60 B Restricted to maximum of 24 below flooring D Pipe must slope back to external drain trap E Pipe must be insulated when exposed to freezing temperatures...

Page 7: ...C Heat Tape Required F Elbow directly into trap To Code Approved Drain or Condensate Pump D Slope Back to Trap E 60 ft Max Length A05290 Fig 9 Horizontal Furnace with ETK Under Furnace FURNACE PIPE DI...

Page 8: ...0 12 20 29 2 5 64 38 12 21 6 40 12 40 12 20 7 3 76 70 21 63 19 70 21 70 21 0 18 3 76 50 15 30 9 70 21 70 21 20 29 3 76 28 9 12 4 70 21 70 21 120 20 7 3 76 70 21 70 21 70 21 70 21 0 18 3 76 61 19 38 12...

Reviews: