background image

2

Table 1 – Gas Furnaces

Single---Stage Furnaces

Two---Stage Furnaces

58MCA

58MCB

58MSA

58MEB

58MXA

58MXB

340MAV

340AAV

345MAV

350MAV

350AAV

351DAS

353AAV

PG9MAA

PG9MAB

58MTA

58MTB

58MEC

352MAV

352AAV

353BAV

PG9MXA

FIRE, EXPLOSION, ELECTRICAL SHOCK

HAZARD

Failure to follow this warning could result in personal injury,

death and/or property damage.
Turn off gas and electrical supplies to unit and tag with

appropriate lockout before beginning any installation or

modification.

Follow all operating instructions on label

attached to furnace.

!

WARNING

INTRODUCTION

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in personal

injury or death.
Do not use this kit with variable--speed furnaces.

Variable--speed inducer pressure could force water out of

this trap and permit vent gas to leak into living space.

!

WARNING

This instruction covers installation of the vent/exhaust pipe

external trap kit P/N KGAET101ETK in all fixed--capacity,

multipoise condensing gas furnaces listed in Table 1.

VENT/EXHAUST PIPE

POSITION TEE AS SHOWN

321496-301

TO OPEN DRAIN

Furnace
Condensate
Trap

OPEN "STAND PIPE"

FOR A/C OR

HUMIDIFIER DRAIN

ALTERNATE VENT/EXHAUST

CONDENSATE TRAP KIT INSTALLATION

322186-201

322187-201

308589-402

A99079

Fig. 1 -- Condensate Trap Plumbing Options for Vent Above

Floor

DESCRIPTION AND USAGE

Use this vent/exhaust pipe external trap kit to reduce gurgle noise
concerns and/or to improve condensate draining in vent/exhaust

pipe.
This vent/exhaust pipe external trap kit contains the following

items:

Condensate trap

1

Tee vent fitting (2-in. (51 mm) PVC)

1

Bushing vent fitting (2 x 1-1/2-in. (51 x 38 mm) PVC)

1

Adapter fitting (1-1/2 (38 mm) male x 1-1/2 (38 mm)

female)

1

INSTALLATION

These instructions are written assuming kit is installed after
furnace and vent system have been installed and is operational.

Kit components and alternate methods of condensate plumbing
are shown in Fig. 1. If installing kit during initial installation,

install as shown in Fig. 2 through 9.

NOTE

: This kit is designed for use with 2--in. (51 mm) PVC

vent/exhaust pipe applications. Additional pipe diameters are
usable when field--supplied PVC fittings are used with
condensate trap and bushing supplied in kit.
Drain pipe and fittings must conform to ANSI standards and

ASTM D1785 or D2846. CPVC or PVC cement and primer must
conform to ASTM D2564 or F493. See section for Special

Venting Requirements for installations in Canada for pipe,
fittings, cement, and primer material requirements for Canadian

installations.

FIRE HAZARD

Failure to follow this warning could result in personal

injury, death or property damage.
Solvent cements are combustible. keep away from heat,

sparks and open flame. Use only in well--ventilated areas.

Avoid breathing in vapor or allowing contact with skin or

eyes.

!

WARNING

NOTE: Slope combustion--air and vent pipes a minimum of 1/4--

in. (6 mm) per linear ft. with no sags between hangers.

UNIT OPERATIONAL HAZARD

Failure to follow this caution may result in intermittent unit

operation.
This kit is intended to be located at the lowest point in the

vent system and no more than 24 in. (610 mm) horizontally

from where the vent exits the furnace to achieve proper

drainage.

CAUTION

!

Summary of Contents for KGAET0101ETK

Page 1: ...rimers and cements from one manufacturer with a vent system from a different manufacturer Follow the manufacturer s instructions in the use of primer and cement and never use primer or cement beyond i...

Page 2: ...kit contains the following items Condensate trap 1 Tee vent fitting 2 in 51 mm PVC 1 Bushing vent fitting 2 x 1 1 2 in 51 x 38 mm PVC 1 Adapter fitting 1 1 2 38 mm male x 1 1 2 38 mm female 1 INSTALLA...

Page 3: ...fitting in place 7 Cement bushing supplied in kit in bottom tee vent fitting connection 8 Position condensate trap supplied in kit in bushing such that drain connection is positioned for suitable fie...

Page 4: ...ondensate trap sides 4 Wrap field drain pipe with remaining heat tape approximately one wrap per ft 5 When using field supplied heat tape follow heat tape manufacturer s instructions for all other ins...

Page 5: ...p and Trap Kit for Vent Above Floor A99082 Fig 4 Upflow Furnace Left Side Outlet with Blower Com partment Condensate Trap Location and Trap Kit for Vent Above Floor A99083 Fig 5 Downflow Furnace Left...

Page 6: ...e Approved Drain A Restricted to maximum of 60 B Restricted to maximum of 24 below flooring D Pipe must slope back to external drain trap E Pipe must be insulated when exposed to freezing temperatures...

Page 7: ...C Heat Tape Required F Elbow directly into trap To Code Approved Drain or Condensate Pump D Slope Back to Trap E 60 ft Max Length A05290 Fig 9 Horizontal Furnace with ETK Under Furnace FURNACE PIPE DI...

Page 8: ...0 12 20 29 2 5 64 38 12 21 6 40 12 40 12 20 7 3 76 70 21 63 19 70 21 70 21 0 18 3 76 50 15 30 9 70 21 70 21 20 29 3 76 28 9 12 4 70 21 70 21 120 20 7 3 76 70 21 70 21 70 21 70 21 0 18 3 76 61 19 38 12...

Reviews: