Table 1 – Gas Furnaces
Single---Stage Furnaces
Two---Stage Furnaces
58MCA
58MCB
58MSA
58MEB
58MXA
58MXB
340MAV
340AAV
345MAV
350MAV
350AAV
351DAS
353AAV
PG9MAA
PG9MAB
58MTA
58MTB
58MEC
352MAV
352AAV
353BAV
PG9MXA
FIRE, EXPLOSION, ELECTRICAL SHOCK
HAZARD
Failure to follow this warning could result in personal injury,
death and/or property damage.
Turn off gas and electrical supplies to unit and tag with
appropriate lockout before beginning any installation or
modification.
Follow all operating instructions on label
attached to furnace.
!
WARNING
INTRODUCTION
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal
injury or death.
Do not use this kit with variable--speed furnaces.
Variable--speed inducer pressure could force water out of
this trap and permit vent gas to leak into living space.
!
WARNING
This instruction covers installation of the vent/exhaust pipe
external trap kit P/N KGAET101ETK in all fixed--capacity,
multipoise condensing gas furnaces listed in Table 1.
VENT/EXHAUST PIPE
POSITION TEE AS SHOWN
321496-301
TO OPEN DRAIN
Furnace
Condensate
Trap
OPEN "STAND PIPE"
FOR A/C OR
HUMIDIFIER DRAIN
ALTERNATE VENT/EXHAUST
CONDENSATE TRAP KIT INSTALLATION
322186-201
322187-201
308589-402
A99079
Fig. 1 -- Condensate Trap Plumbing Options for Vent Above
Floor
DESCRIPTION AND USAGE
Use this vent/exhaust pipe external trap kit to reduce gurgle noise
concerns and/or to improve condensate draining in vent/exhaust
pipe.
This vent/exhaust pipe external trap kit contains the following
items:
Condensate trap
1
Tee vent fitting (2-in. (51 mm) PVC)
1
Bushing vent fitting (2 x 1-1/2-in. (51 x 38 mm) PVC)
1
Adapter fitting (1-1/2 (38 mm) male x 1-1/2 (38 mm)
female)
1
INSTALLATION
These instructions are written assuming kit is installed after
furnace and vent system have been installed and is operational.
Kit components and alternate methods of condensate plumbing
are shown in Fig. 1. If installing kit during initial installation,
install as shown in Fig. 2 through 9.
NOTE
: This kit is designed for use with 2--in. (51 mm) PVC
vent/exhaust pipe applications. Additional pipe diameters are
usable when field--supplied PVC fittings are used with
condensate trap and bushing supplied in kit.
Drain pipe and fittings must conform to ANSI standards and
ASTM D1785 or D2846. CPVC or PVC cement and primer must
conform to ASTM D2564 or F493. See section for Special
Venting Requirements for installations in Canada for pipe,
fittings, cement, and primer material requirements for Canadian
installations.
FIRE HAZARD
Failure to follow this warning could result in personal
injury, death or property damage.
Solvent cements are combustible. keep away from heat,
sparks and open flame. Use only in well--ventilated areas.
Avoid breathing in vapor or allowing contact with skin or
eyes.
!
WARNING
NOTE: Slope combustion--air and vent pipes a minimum of 1/4--
in. (6 mm) per linear ft. with no sags between hangers.
UNIT OPERATIONAL HAZARD
Failure to follow this caution may result in intermittent unit
operation.
This kit is intended to be located at the lowest point in the
vent system and no more than 24 in. (610 mm) horizontally
from where the vent exits the furnace to achieve proper
drainage.
CAUTION
!