33
d
Default = 120 seconds
6.3.3.6.
Altitude
For gas de--rating, this setting will adjust the furnace’s airflow to compensate for
altitude. Altitude adjustment is not available with older furnaces. Please see furnace
instructions for further details. After the selection is made, touch
SAVE
.
S
Altitude:
0000 – 2000, US 2001 – 3000, CN 2100 – 4500, US 3001 – 4000,
US 4001 – 5000, US 5001 6000, US 6001 – 7000, US 7001 – 8000, US 8001 –
9000, and US > 9000.
d
Default = US 2001--3000
S
Static Pressure selection:
0 to 10,000 feet. This value is used to correct the
static pressure readings the system performs.
6.3.3.7.
Furnace Dehumidifier Drain
This option selects the time the continuous fan turns off at the end of cooling in
order to drain the indoor coil of water. The fan will only be turned off if a
dehumidify demand existed at the start of or during the cooling cycle.
S
Dehumidify Drain Time:
Adjustable from 5 to 60 minutes
d
Default = 15 minutes
6.3.3.8.
Furnace G Terminal
This setup option selects desired operation when the R--G circuit changes state on
the furnace control board depending on setup.
Under the function option,
FAN
turns on fan to selected fan speed when G terminal
is energized.
SHUTDOWN
shuts off fan and equipment when initiated.
After the selections are made, touch
SAVE
.
S
Function
: Disabled, Fan or Shutdown
d
Default = Disabled
Summary of Contents for Infinity SYSTXCCITN01
Page 2: ......
Page 79: ...71 R G FE Fan Coil or Variable Speed Furnace A07114 G Input Wiring for Blower Operation ...
Page 80: ...72 R G FE Fan Coil or Variable Speed Furnace A07115 G Input Wiring for System Shutdown ...
Page 81: ...73 NOTES ...
Page 82: ...74 NOTES ...
Page 83: ......