Fig. 13 — Typical Wiring Connections (30MP015-45 Units)

MAIN

BASE

BOARD

FIOP/

ON

OFF

1 2 3 4 5 6 7 8

DARK = SWITCH LOCATION

DUS

3
2
1
3
2
1

6
5
4
3
2
1

J9

2

1

8

7

2

1

8

7

J2

J6

DTT

RED

WHT

BLK

DGS

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7

J7

EMM

4
3
2
1

4
3
2
1

J3

4
3
2
1

4
3
2
1

J4

RED

WHT

BLK

RED

WHT

BLK

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7

J6

14

13

14

13

ACCESSORY

1

1
2
3
4
5
6

1
2
3
4
5
6

14

15

4

3

12

13

6

5

10

11

7

8

9

8

6

7

4

5

9

2

3

10

+
-

COOLING

SETPOINT

4-20mA

RED
RED
BLU
BLU

PNK

ORN

BRN

VIO

+
-

TEMP

RESET

4-20mA

+
-

DEMAND

LIMIT

4-20mA

DLS STEP 2

VIO
BRN

RED
BLK

CH1

-

CH11

-

-

+

G

-

+

G

DLS STEP 1

LVT

16

17

2

1

GRA
GRA

ICE DONE

3
4

4

3

2

2

1

1

BLK

WHT

RED

J3

FIOP

J10

AUX2

LEGEND

EMM

Energy Management Module

MBB

Main Base Board

FIOP

Factory-Installed Option

Field Wiring

LVT

Low Voltage Terminal

A38-7212

A38-7211

3

3

2

2

1

1

J2

BRN
VIO

2

2
1

J1

1

3

3

MBB

BRN
RED

3

3

2

2

1

1

J2

2

J1

1

3

FIOP/ACCESSORY

EMM

24-V POWER CONNECTION

StockCheck.com

Summary of Contents for GEMINI SELECT 38APD025-130

Page 1: ...ignal ACCESSORY PACKAGE CONTENTS LEGEND INSTALLATION NOTE Component arrangement drawings and wiring dia grams show available options that may not be applicable to your unit 1 Inspect the package conte...

Page 2: ...es should be set to ON CEBD430351 0396 01C TEST 1 CEPL130351 01 PWR TEST 2 J1 J2 J4 J3 J5 J6 J7 LEN STATUS RED LED STATUS GREEN LED LEN LOCAL EQUIPMENT NETWORK ADDRESS DIP SWITCH Fig 1 EMM Board LVT F...

Page 3: ...EMM 30RAP010 and 015 Units LEGEND FOR FIG 3 5 CB Circuit Breaker CCB CompressorCircuit Breaker CXB Compressor Expansion Board EMM Energy Management Module EQUIP Equipment GND Ground LVT Low Voltage Te...

Page 4: ...PC TB1 TB4 MBB MS CWP1 MS CWP2 FR 3 C B1 CSB B1 CB 3 CHC CWP1 CWP2 FR 4 CSB B2 C B2 CB 4 DISCONNECT OPTION TB LVT Fig 6 Mounting EMM 30RAP018 030 Units Fig 7 Mounting EMM Typical 30RAP035 150 Units 03...

Page 5: ...X BOARD Per form the following procedure to install the harness and make the wiring connections See Fig 10 for wiring Install the new harness 38APHLSLCE A00 provided 1 Install plug labeled CXB J4 to C...

Page 6: ...and J7 and other end labeled LVT J10 to LVT terminal strip 30MP015 045 UNITS WITH AUX BOARD Perform the following procedure to install the harness and make the wiring connections See Fig 13 for wirin...

Page 7: ...RED BLU BLU PNK ORN BRN VIO TEMP RESET 4 20mA DEMAND LIMIT 4 20mA DEMAND LIMIT STEP 1 OR Y3 DEMAND LIMIT STEP 2 OR Y4 DGS OR MM FIOP DUS 2 1 8 7 2 1 8 7 J2 J6 DTT VIO BRN RED BLK 2 1 2 1 RED BLK J4 CH...

Page 8: ...6 14 15 4 3 12 13 6 5 10 11 7 8 9 8 6 7 4 5 9 2 3 10 COOLING SETPOINT 4 20mA RED RED BLU BLU PNK ORN BRN VIO TEMP RESET 4 20mA DEMAND LIMIT 4 20mA DEMAND LIMIT STEP 1 OR Y3 DEMAND LIMIT STEP 2 OR Y4...

Page 9: ...3 12 13 6 5 11 RED RED BLU BLU DLS STEP 2 DLS STEP 1 LVT 16 17 2 1 GRA GRA ICE DONE J10 Fig 11 Typical Wiring Connections 30RAP010 060 Units a30 4945 A38 7212 3 3 2 2 1 1 J2 BRN VIO 2 2 1 J1 1 3 3 MBB...

Page 10: ...3 4 5 6 1 2 3 4 5 6 14 15 4 3 12 13 6 5 10 11 7 8 9 8 6 7 4 5 9 2 3 10 COOLING SETPOINT 4 20mA RED RED BLU BLU PNK ORN BRN VIO TEMP RESET 4 20mA DEMAND LIMIT 4 20mA DLS STEP 2 VIO BRN RED BLK CH1 CH1...

Page 11: ...S t o c k C h e c k c o m...

Page 12: ...inue or change at any time specifications or designs without notice and without incurring obligations Catalog No 04 53300104 01 Printed in U S A Form 30 38 11SI Pg 12 11 12 Replaces 30 38 7SI Carrier...

Reviews: