background image

7

d. The power indicator light above the Air Purifier power

switch should illuminate (see Fig. 10).

e. Check to ensure the light goes off when the Infinity Air

Purifier power switch is set to off, when the blower goes off,
or when the HVAC system power is turned off.

Infinity Control

When the Infinity Air Purifier is used with an Infinity Control, the
Infinity Control can be configured to remind the homeowner when

it is time to change the Infinity Air Purifier cartridge. This

maintenance reminder can be based on either the TrueSense

t

dirty

filter algorithm or time. The installer should use their discretion to

select the most appropriate option based on the initial system static
pressure.

Maximizing Performance

Maximum air purification performance is obtained when the

furnace blower is set for continuous operation on the thermostat or
Infinity Control.

MAINTENANCE

The Infinity Air Purifier is designed to require minimal

maintenance. Maintenance is limited to the periodic replacement of
the air purification cartridge and inspection/brush cleaning of the

ionization array. Frequency of air purifier cartridge replacement
and cleaning of the ionization array may vary depending on

ductwork design and local environmental conditions, generally

8--12 months.

FIRE HAZARD

Failure to follow this warning could result in personal injury

or equipment damage.
Use of non--factory approved filter cartridge will void the

warranty and may cause damage due to fire.

!

WARNING

To replace the air purifier cartridge, complete the

following steps:

Turn the heating and cooling system power

off.

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury

or death.
Before installing or servicing system, always turn off main

power to system. There may be more than one (1) disconnect

switch.

!

WARNING

Turn the Infinity Air Purifier switch to the off position.
Remove the Infinity Air Purifier door.
Slide out the old air purifier cartridge and discard.
Install the new air purifier cartridge. Make sure the power cord is

flexed out of the way to avoid damage to the air purifier cartridge

pleats during insertion.

NOTE

: Verify that the air purifier cartridge is installed correctly.

Make sure that the arrows on the air purifier cartridge point toward
the furnace. This should be in the same direction as airflow and
match the arrows on the sticker inside the cabinet.
Replace the Infinity Air Purifier door.
Turn the Infinity Air Purifier switch to the on position.
Turn heating and cooling system power on.

CARBON MONOXIDE HAZARD

Failure to follow this warning could result in personal injury

or death.
Do not remove door during blower operation or operate

blower with door removed or improperly latched.

!

WARNING

Power Indicator

A06052

Fig. 10 -- Power Indicator

At the time of air purifier cartridge replacement, if a powdery

residue is noticed on the tips of the points in the ionization array,
proceed to clean them by completing the following steps.

Turn heating and cooling system power off.

ELECTRICAL SHOCK AND HIGH VOLTAGE

HAZARD

Failure to follow this warning could result in personal injury

or death.
Before installing or servicing system, always turn off main

power to system. There may be more than one (1) disconnect

switch.

!

WARNING

Turn the Infinity Air Purifier switch to the off position.
Remove the Infinity Air Purifier door.
Unplug the power cord from the enhancement module.
Slide out the enhancement module assembly and safety screen.

CUT HAZARD

Failure to follow this warning could result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and

wear appropriate protective clothing and gloves when

handling parts.

!

WARNING

Slide out the Safety Screen and set aside.

NOTE

: Best cleaning tools: 5--in (127 mm) handle paint brush

with 2--in (51 mm) width (or greater) brush point (synthetic or

GAP

A

A

Summary of Contents for GAPAA

Page 1: ...ification CSA vise uniquement les risques de choc electrique et A05265 Fig 1 GAPAA Unit SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause death personal injury or property damage Consult a qualified installer service agency or your distributor or branch for information or assist...

Page 2: ...on should be done at every change of the air purifier cartridge minimum annually HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death This air purifier utilizes high voltage If you notice water running into or around the air purifier water stains on the purifier cartridge or on the Enhancement Module walls or cabinet shut off the air purifier and call your se...

Page 3: ...entation c The location of the Infinity Air Purifier should be readily accessible Enough room should be provided for periodic replacement of the air purifier cartridges ELECTRIC SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death Only a trained experienced service person should install the Infinity Air Purifier A thorough check of the unit installat...

Page 4: ...ow Furnace Note When transitioning between two different sized components furnace purfier the minimum transition angle at the larger of the two components must be no less than 45 degrees A08608 Fig 4 Infinity Air Purifier Cabinet Orientation with Transition Furnace Adapters x2 Return Duct Adapters x4 Return Duct Furnace Adapters x2 Return Duct Adapters x4 Return Duct Top Mount Bottom Mount Side Mo...

Page 5: ... should be used to connect the upstream side of the air purifier cabinet to the return air duct see Fig 7 g Install foam tape between the furnace and the air purifier cabinet h Mounting holes are provided for ductwork and furnace at tachment Note Slip S cleats onto flanges on air return duct side A05277 Fig 7 Use of Return Duct Adapters UNIT DAMAGE HAZARD Failure to follow this caution may result ...

Page 6: ... the side of the power supply e Attach the quick connect terminals to the furnace EAC 1 and EAC 2 spade connections Attach the ground ring to furnace chassis ground NOTE The Infinity Air Purifier is to be powered by 115v 60 Hz NOTE The Infinity Air Purifier should only be powered when airflow is present The furnace control EAC spade connections provide power only when the furnace blower is operati...

Page 7: ...urn the Infinity Air Purifier switch to the off position Remove the Infinity Air Purifier door Slide out the old air purifier cartridge and discard Install the new air purifier cartridge Make sure the power cord is flexed out of the way to avoid damage to the air purifier cartridge pleats during insertion NOTE Verify that the air purifier cartridge is installed correctly Make sure that the arrows ...

Page 8: ...AREFUL DURING CLEANING Tip of point with residue Tip of point after cleaning A06671 Fig 11 Removal of Deposits from Ionization Pins TROUBLESHOOTING SAFETY HAZARD Failure to follow this caution may result in personal injury or equipment damage The following instructions are for use by qualified personnel only CAUTION ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal in...

Page 9: ...o cabinet cartridge to cabinet on the leaving air side are securely in place and making clean contact S Arcing to ground such as unit cabinet is occurring S Make sure the safety screen is clear and remove debris S Arcing to ground is occurring due to debris lodged in the safety screen or across ionization grid S Make sure the ionization grid is secured in place with all four clips and centered in ...

Page 10: ...FM 1600 2000 Efficiency MERV 15 MERV 15 Replacement Cartridge GAPCCCAR1625 GAPCCCAR2025 Pressure Drop Maximum Airflow 25 InH20 25 InH20 Dimensions GAPAAXCC1625 GAPAAXCC2025 A 18 3 8 in 466 7mm 21 7 8 in 555 6mm B 15 1 8 in 384 1mm 18 5 8 in 473 1mm C 11 1 8 in 282 6mm 11 1 8 in 282 6mm D 17 1 2 in 444 5mm 21 in 533 4mm E 22 1 8 in 562mm 22 1 8 in 562mm F 25 1 4 in 642 4mm 25 1 4 in 642 4mm 7 16 11...

Page 11: ...s and exclusions listed below and on the reverse if any of this document OWNER OCCUPIED RESIDENTIAL APPLICATIONS This warranty is to the original purchasing owner and is transferable only to the extent and as stated in the Warranty Conditions and below The warranty period in years depending on the part and the claimant is as shown in the chart below Limited Warranty Years Product Original Owner Su...

Page 12: ...ONS ON HOW LONG AN IMPLIED WARRANTY OR CONDITION LASTS SO THE ABOVE MAY NOT APPLY TO YOU THE EXPRESS WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHATSOEVER THIS WARRANTY DOES NOT COVER 1 Labor or other costs incurred for diagnosing repairing removing installing shipping servicing or handling of either defective...

Reviews: