5

Mount Cabinet

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury

or death.
Before installing or servicing system, always turn off main

power to system. There may be more than 1 disconnect switch.

!

WARNING

UNIT DAMAGE HAZARD

Failure to follow this caution may result in equipment

damage.
Cabinets will support a maximum weight of 400 lbs/181 kg

when installed beneath a vertical furnace or air--handling

unit. When setting furnace on cabinet, do not drop it into

place. Position the furnace correctly on the cabinet to prevent

a corner from slipping down and damaging the cabinet or its

components.

CAUTION

!

a. Turn off power to the heating and cooling system.

b. Remove the existing furnace filter and discard. Excessive

system static may result if the Infinity Air Purifier is used
with other filtration devices.

c. Remove the air purifier cartridge and enhancement module

from the Infinity Air Purifier cabinet.

d. Position the cabinet between the furnace and return air duct

(see Figures 3, 4, 5 and 6). A transition duct may be re-
quired.

e. Furnace adapters have been included for installer conve-

nience. They are designed for top or bottom mount installa-

tions (see Fig. 6).

Furnace
Adapters

Airflow

Airflow

A05274

Fig. 6 -- Use of Furnace Adapters

f. Return air duct adapters have been included for installer

convenience. They should be used to connect the upstream
side of the air purifier cabinet to the return air duct (see Fig.

7).

g. Install foam tape between the furnace and the air purifier

cabinet.

h. Mounting holes are provided for ductwork and furnace at-

tachment.

       Note: Slip 
S-cleats onto flanges
on air return duct side.

A05277

Fig. 7 -- Use of Return Duct Adapters

UNIT DAMAGE HAZARD

Failure to follow this caution may result in unit damage.
Mounting holes are provided for duct work and furnace

attachment. The screws on the down--stream side of the

cabinet should be installed so that the screw heads are inside

air purifier cabinet to prevent damage to the air purifier

cartridge.

CAUTION

!

i. Seal seams with tape or caulking after the Infinity Air Puri-

fier cabinet has been secured.

Special consideration must be given when applying the 2025 Air

Purifier to a 24 1/2--in (622 mm) wide furnace.

a. Prepare transition, following recommended transition draw-

ing (see Fig. 8). Fabricate a 2 1/4--in (57 mm) tall (minim-
um) transition.

b. Place transition on top of Air Purifier. Secure with sheet

metal screws. Place furnace on top of transition. Make sure
furnace rests evenly on top of transition and Air Purifier.

c. Secure furnace to transition using sheet metal screws. See

Fig. 4.

d. Continue with normal installation practices.

A

(Inside Opening)

Air Purifier Outlet

Front Bracket

Rear Bracket

Furnace Casing Width 24 1/2” (622)

Side Bracket

Side Bracket

NOTE:

 Weld 3 places 

in 4 corners

2 1/4” (57)

24” (610)
(Outside)

5/8” (16)
Flanges
(Where Shown)

B

19 1/2” (495)

A09001

Fig. 8 -- Recommended Transition

GAP

A

A

Summary of Contents for GAPAA

Page 1: ...ification CSA vise uniquement les risques de choc electrique et A05265 Fig 1 GAPAA Unit SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause death personal injury or property damage Consult a qualified installer service agency or your distributor or branch for information or assist...

Page 2: ...on should be done at every change of the air purifier cartridge minimum annually HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death This air purifier utilizes high voltage If you notice water running into or around the air purifier water stains on the purifier cartridge or on the Enhancement Module walls or cabinet shut off the air purifier and call your se...

Page 3: ...entation c The location of the Infinity Air Purifier should be readily accessible Enough room should be provided for periodic replacement of the air purifier cartridges ELECTRIC SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death Only a trained experienced service person should install the Infinity Air Purifier A thorough check of the unit installat...

Page 4: ...ow Furnace Note When transitioning between two different sized components furnace purfier the minimum transition angle at the larger of the two components must be no less than 45 degrees A08608 Fig 4 Infinity Air Purifier Cabinet Orientation with Transition Furnace Adapters x2 Return Duct Adapters x4 Return Duct Furnace Adapters x2 Return Duct Adapters x4 Return Duct Top Mount Bottom Mount Side Mo...

Page 5: ... should be used to connect the upstream side of the air purifier cabinet to the return air duct see Fig 7 g Install foam tape between the furnace and the air purifier cabinet h Mounting holes are provided for ductwork and furnace at tachment Note Slip S cleats onto flanges on air return duct side A05277 Fig 7 Use of Return Duct Adapters UNIT DAMAGE HAZARD Failure to follow this caution may result ...

Page 6: ... the side of the power supply e Attach the quick connect terminals to the furnace EAC 1 and EAC 2 spade connections Attach the ground ring to furnace chassis ground NOTE The Infinity Air Purifier is to be powered by 115v 60 Hz NOTE The Infinity Air Purifier should only be powered when airflow is present The furnace control EAC spade connections provide power only when the furnace blower is operati...

Page 7: ...urn the Infinity Air Purifier switch to the off position Remove the Infinity Air Purifier door Slide out the old air purifier cartridge and discard Install the new air purifier cartridge Make sure the power cord is flexed out of the way to avoid damage to the air purifier cartridge pleats during insertion NOTE Verify that the air purifier cartridge is installed correctly Make sure that the arrows ...

Page 8: ...AREFUL DURING CLEANING Tip of point with residue Tip of point after cleaning A06671 Fig 11 Removal of Deposits from Ionization Pins TROUBLESHOOTING SAFETY HAZARD Failure to follow this caution may result in personal injury or equipment damage The following instructions are for use by qualified personnel only CAUTION ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal in...

Page 9: ...o cabinet cartridge to cabinet on the leaving air side are securely in place and making clean contact S Arcing to ground such as unit cabinet is occurring S Make sure the safety screen is clear and remove debris S Arcing to ground is occurring due to debris lodged in the safety screen or across ionization grid S Make sure the ionization grid is secured in place with all four clips and centered in ...

Page 10: ...FM 1600 2000 Efficiency MERV 15 MERV 15 Replacement Cartridge GAPCCCAR1625 GAPCCCAR2025 Pressure Drop Maximum Airflow 25 InH20 25 InH20 Dimensions GAPAAXCC1625 GAPAAXCC2025 A 18 3 8 in 466 7mm 21 7 8 in 555 6mm B 15 1 8 in 384 1mm 18 5 8 in 473 1mm C 11 1 8 in 282 6mm 11 1 8 in 282 6mm D 17 1 2 in 444 5mm 21 in 533 4mm E 22 1 8 in 562mm 22 1 8 in 562mm F 25 1 4 in 642 4mm 25 1 4 in 642 4mm 7 16 11...

Page 11: ...s and exclusions listed below and on the reverse if any of this document OWNER OCCUPIED RESIDENTIAL APPLICATIONS This warranty is to the original purchasing owner and is transferable only to the extent and as stated in the Warranty Conditions and below The warranty period in years depending on the part and the claimant is as shown in the chart below Limited Warranty Years Product Original Owner Su...

Page 12: ...ONS ON HOW LONG AN IMPLIED WARRANTY OR CONDITION LASTS SO THE ABOVE MAY NOT APPLY TO YOU THE EXPRESS WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHATSOEVER THIS WARRANTY DOES NOT COVER 1 Labor or other costs incurred for diagnosing repairing removing installing shipping servicing or handling of either defective...

Reviews: