GA5S: Installation Instructions

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

10

Final Checks

IMPORTANT: 

Before leaving job, be sure to do the following:

1. Ensure that all wiring is routed away from tubing and sheet metal

edges to prevent rub-through or wire pinching. 

2. Ensure that all wiring  and  tubing  is  secure  in  unit  before adding

panels and covers. Securely fasten all panels and covers. 

3. Tighten service valve stem caps to 1/12-turn past finger tight.
4. Leave Owner’s Manual with owner. Explain system operation and

periodic maintenance requirements outlined in manual. 

5. Fill out Dealer Installation Checklist and  place in customer file.

Repairing Refrigerant Circuit 

When  breaking into  the refrigerant  circuit  to make  repairs, or for any

other purpose, the following procedures shall be used. 

1. Safely remove the refrigerant using a recovery pump certified for

flammable refrigerants. 

2. Purge the refrigerant circuit with nitrogen gas. 
3. Evacuate the refrigerant circuit to 1500 microns. 
4. Break  vacuum  with  a  nitrogen  purge  of  the  refrigerant  circuit

ensuring that the outlet of the vacuum pump is not near a potential

ignition source. 

5. Open the circuit by cutting or brazing. 

CARE AND MAINTENANCE

For  continuing high performance and  to minimize  possible  equipment

failure, periodic maintenance must be performed on this equipment. 
Frequency of maintenance may vary depending upon geographic areas,

such as coastal applications. See Owner’s Manual for information. 

Summary of Contents for GA5S

Page 1: ...away from windows patios decks etc where unit operation sound may disturb customer 3 Ensure that vapor and liquid tube diameters are appropriate for unit capacity 4 Run refrigerant tubes with no bends...

Page 2: ...ce Requirements When installing allow sufficient space for airflow clearance wiring refrigerant piping and service Allow 24 in 610 mm clearance to service end of unit and 48 in 1219 mm above unit For...

Page 3: ...rit or debris Insert line set tube ends into service valve tube stubs Apply heat absorbing paste or heat sink product between service valve and joint Wrap service valves with a heat sinking material s...

Page 4: ...s vacuum depth 1 Vacuum unit to 500 microns 2 When isolating the unit from the pump the pressure shall not rise above 1500 microns in 10 minutes Final Tubing Check IMPORTANT Check to be certain factor...

Page 5: ...nimum of 15 minutes before checking charge 2 Measure suction pressure by attaching an accurate gage to suction valve service port 3 Measure suction temperature by attaching an accurate thermistor type...

Page 6: ...4 110 43 108 42 106 41 104 40 102 39 416 114 46 112 44 110 43 108 42 106 41 104 40 427 116 47 114 46 112 44 110 43 108 42 106 41 439 118 48 116 47 114 46 112 44 110 43 108 42 450 120 49 118 48 116 47...

Page 7: ...et and connect leads to control wiring Refer to thermostat Installation Instructions for wiring specific unit combinations see Fig 7 Use No 18 AWG color coded insulated 35 C minimum wire If thermostat...

Page 8: ...ash if a phase problem exists See code descriptions on monitor If LED is flashing disconnect power to unit and interchange 2 field wiring leads on unit contactor A00010 Fig 8 3 Phase Monitor Control A...

Page 9: ...evel should then be appropriate for the system to achieve rated capacity The charge level could then be checked at another time when the both indoor and outdoor temperatures are in a more favorable ra...

Page 10: ...requirements outlined in manual 5 Fill out Dealer Installation Checklist and place in customer file Repairing Refrigerant Circuit When breaking into the refrigerant circuit to make repairs or for any...

Reviews: