8
SELECT LOCATION FOR THE AIR CLEANER
DIRECTION OF AIR FLOW THROUGH THE AIR CLEANER
PHYSICAL INSTALLATION
Select a location that is readily accessible for periodic inspection and
cleaning. Allow a minimum of 26" in front of the access panel for filter
removal. For complete dimensions required, refer to the section entitled
The air cleaner is set up for left to right air flow, when facing the access
door. For right to left air flow remove filter cartridge, turn it around and
replace in cabinet. The directional arrows on the filter cartridge must
point in the direction of air flow.
The air cleaner can be in any position, except with the access door
facing down. The section entitled
(page 5) shows proper air cleaner mounting with a variety of furnace
installations.
Prior to installing this product...
1. Read rules and instructions carefully for safe operation. Failure to
follow them could damage the product or cause a hazardous
condition.
2. Check the ratings given on the product to make sure it is suitable for
your application.
3. Remove the old furnace filter and discard.
4. The air cleaner cannot remove existing dirt from the blower and
ducts.
SPECIFICATIONS.
TYPICAL MOUNTING POSITIONS